Honeywell W4115B-1317 PCB for Gas Boiler

Honeywell W4115B-1317 PCB for Gas Boiler

It is the PCB that controls the boiler: it manages the ignition, the fan or the pump, the sensors, and the gas valve.

internal SKU
TC00596ATX
Warranty
1 year
VAT included Stock · 2 units
Compatibility

Honeywell compatible boilers

PCB. 0 verified compatibilities. There are another 15 models that we are still checking.

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Honeywell Ferroli NE Fluss 20 CEHoneywellUnconfirmed
Honeywell Ferroli NE Fluss 20 EL PN CEHoneywellUnconfirmed
Honeywell Ferroli NE Fluss 20 PN CEHoneywellUnconfirmed
Honeywell Ferroli NE Fluss 20 EL CEHoneywellUnconfirmed
Honeywell Ferroli Master CE 20 MELHoneywellUnconfirmed
Honeywell Ferroli Mikra 20 CE MELHoneywellUnconfirmed
Honeywell Ferroli NE TF 120 CEHoneywellUnconfirmed
Honeywell Ferroli NEF96HoneywellUnconfirmed
Honeywell Ferroli NEFA20CEHoneywellUnconfirmed
Honeywell Ferroli NEWELITEHoneywellUnconfirmed
Honeywell Ferroli Optima 601, 801 and 901HoneywellUnconfirmed
Honeywell Ferroli Optima 201, 1001 and 2001HoneywellUnconfirmed
Honeywell Ferroli Hawk II and Optima 701HoneywellUnconfirmed
Honeywell Ferroli Hawk 11HoneywellUnconfirmed
Honeywell Ferroli Optima 700 COMBI NGHoneywellUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Check the label for the designation W4115B-1317 and compare it with yours. Variants with a different suffix (W4115B1192, W 4115 B 1218B, W4115B1325, w4115b1333u): make sure yours is 1317.
  2. Also compare the marked 963743 1968 and 9640 MF7 from the PCB, and in the transformer, SEMAR 31101007 or 311101007 / 45006113-001.
  3. Compare the layout and connectors with the photos: the PCB indicates 230 V 50 Hz and "2AT" as protection.
  4. To confirm: If the breakdown of your boiler shows the Ferroli code 39803410, check the suffix of your PCB: it connects to W4115B1317 and four to W4115B1325. None state that they are interchangeable.
  5. Any questions? Send us a photo of your part's label and the boiler's rating plate from Contact.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite: the burner does not start and fault code A01 appears.

    Cause: There is no gas, broken electrode, or faulty gas valve.

    Check that gas is arriving and reset once. If it repeats, have a technician check it.

  • 02

    The boiler detects flame with the burner off and locks out (A02).

    Cause: Electrode or PCB anomaly.

    Check the electrode and its wiring. If they are fine, have a technician check the PCB.

  • 03

    The boiler locks out due to overheating (A03).

    Cause: Heating sensor faulty or lack of water circulation.

    Bleed the air and check the pump. If it happens again, have a technician check it.

  • 04

    The burner does not ignite and the boiler shows A01.

    Cause: Gas, electrode, gas valve or PCB.

    Reset once. If it blocks again, have a technician check it.

  • 05

    The boiler displays F39 (external sensor) or F42 (heating sensor) on the screen.

    Cause: Faulty sensor, or cut wiring or short circuit.

    Have a technician check the sensor and its wiring.

Honeywell fault codes that require diagnosis

CodeFaultTechnical checks
A01Ignition failure: the burner does not ignite and the boiler locks out.Check that gas is reaching and that the electrode is not dirty or broken. If it returns after resetting, it points to the PCB or the gas valve: have a technician check it. List of the Ferroli range; confirm in the Master manual.
A02There is a flame signal with the burner off and the boiler locks out.Check the wiring and the condition of the ionization electrode and the siphon. If the electrode is fine, the PCB is the part to check: have a technician look at it. Confirm in the Master manual.
A03Overtemperature protection: the boiler locks out due to excessive heat.Check that there is water circulation and that there is no air in the system. If the issue persists, it points to the heating sensor or the PCB: have a technician check it. Confirm in the Master manual.
F12Fault in the domestic hot water sensor.Check the wiring and the domestic hot water sensor. If they are fine, the PCB may be reading the sensor incorrectly. Confirm in the Master manual.
A06There is no flame after the ignition phase.If it is repeated, a technician should check the gas, electrode, and burner regulation before replacing the PCB. Confirmed only at the Ferroli brand level; source for this range is missing.
F10Return sensor anomaly.If the wiring of the sensor is fine, the sensor may be faulty. Have a technician check it. Confirmed only at the Ferroli brand level; source for this range is missing.
F39External sensor anomaly.Short-circuited wiring or faulty sensor; also if the sensor is disconnected with the adjustable temperature active. Have a technician check it. Confirmed only at the Ferroli brand level; source for this range is missing.
F42Heating sensor anomaly.Heating sensor faulty or wiring cut. Have it checked by a technician. Confirmed only at the Ferroli brand level; source for this range is missing.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: Honeywell PCB

Uniclima internal SKU
TC00596ATX
Brand
Honeywell
Type of part
PCBs (control boards)
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

PCB silkscreen
230 V 50 Hz
Transformer: marked input
PRI230V50/60Hz
Transformer: marked outputs
SEC24V8VA/18V2VA
Protection screen printing
2AT
Inventory — Application indicated in inventory
Compatible with reference: Honeywell W4156B-1312 control PCB for gas boiler. Manages ignition, fan/pump, sensors, and gas valve. This refurbished unit is validated by the silkscreen on the PCB itself. There is no verified boiler model: compare references and connectors with your original PCB before purchasing.
Inventory — PCB
marked supply 230 V, 50 Hz
Inventory — Subcomponent transformer SEMAR 311101007
primary 230 V 50/60 Hz; secondary 24 V 8 VA / 18 V 0.2 VA
Inventory — Subcomponent transformer SETRA 42008113-001
50 Hz; marked date 08/96
Inventory — Subcomponent transformer SEMAR 31101007 / 45006113-001
primary 230 V 50/60 Hz; secondary visible 24 V 8 VA / 18 V
Identification — Marked designation
W4115B-1317
Identification — Marked code
963743 1968; 9640 MF7
Identification — Marked code
SEMAR31101007; 45006113-001
Technical sheet: Screen printing of PCB
230 V 50 Hz
Transformer: marked input
PRI230V50/60Hz
Technical sheet: Transformer: marked outputs
SEC24V8VA/18V2VA
Technical sheet: Protection screen printing
2AT
Inventory data — Application indicated in inventory
Compatibilities:
Inventory data — Application indicated in inventory
Honeywell W4156B-1312 control PCB for gas boiler. Manages ignition, fan/pump, sensors, and gas valve. This refurbished unit is validated by the silkscreen on the PCB itself. There is no verified boiler model: compare references and connectors with your original PCB before purchasing.
Inventory data — PCB
marked supply 230 V, 50 Hz
Inventory data — SEMAR transformer subcomponent 311101007
primary 230 V 50/60 Hz; secondary 24 V 8 VA / 18 V 0.2 VA
Inventory data — Subcomponent transformer SETRA 42008113-001
50 Hz; marked date 08/96
Inventory data — Subcomponent transformer SEMAR 31101007 / 45006113-001
primary 230 V 50/60 Hz; secondary visible 24 V 8 VA / 18 V
Before purchasing
  • To confirm: Ferroli NE Fluss 20 CE — Via 39803410
  • To confirm: Ferroli NE Fluss 20 EL PN CE — Via 39803410
  • To confirm: Ferroli NE Fluss 20 PN CE — Via 39803410
  • To confirm: Ferroli NE Fluss 20 EL CE — Via 39803410
  • To confirm: Ferroli Master CE 20 MEL — Via 39803410
  • To confirm: Ferroli Mikra 20 CE MEL — Via 39803410
  • To confirm: Ferroli NE TF 120 CE — Via 39803410
  • To confirm: Ferroli NEF96 — Via 39803410
  • To confirm: Ferroli NEFA20CE — Via 39803410
  • To confirm: Ferroli NEWELITE — Vía 39803410
  • To confirm: Ferroli Optima 601, 801 and 901 — Via 39803410 ·: 2 British and, country not confirmed
  • To confirm: Ferroli Optima 201, 1001 and 2001 — Via 39803410 · British
  • To confirm: Ferroli Hawk II and Optima 701 — Via 39803410 · each one: (country not confirmed) and a British one (for Hawk II, for Optima 701)
  • To confirm: Ferroli Hawk 11 — Via 39803410
  • To confirm: Ferroli Optima 700 COMBI NG — Via 39803410
  • Not compatible or excluded: Ferroli NE FLUSS 20 CR EL CE — List of parts for Ferroli NE FLUSS 20 CR EL CE, ed. 10.96 (PDF in): it includes the PCB 3831696/0 (W 7075 C 1001). No others.
  • Do not confuse: W4115B1325 — Honeywell VMF7 PCB (also 1325B or 1325/U) with 39803410 and that Italian ones are for Ferroli NE Fluss 20 and NE100/NE127 — Another suffix (1325, not 1317). Unconfirmed: if they are interchangeable.
  • Do not confuse: W4115B1192 / W411581333 — Honeywell ignition boxes from the W4115 series (Antares K.226.01 and K.226.04), for Ferroli — Other suffixes: it is not the 1317.
  • Do not confuse: W 4115 B 1218B — Honeywell PCB W 4115 B 1218B (fault code 98.28405) — Another suffix: it is not the 1317.
  • Do not confuse: w4115b1333u — SM07408 modulation PCB in the listing (another product from the same) — It is a different modulation PCB.
Frequently Asked Questions

Frequently asked questions about the PCB (control board)

How do I identify the Honeywell W4115B-1317 PCB?
Look for the designation W4115B-1317 marked on the plate. Also compare the markings 963743 1968 and 9640 MF7, and in the transformer, SEMAR 31101007 or 311101007 / 45006113-001. If the suffix is not 1317, the designation does not match this plate.
What boiler is the W4115B-1317 compatible with?
there is no confirmed boiler model for this unit and Unconfirmed: the W4115B-1317 along with a boiler. Registered designation: Ferroli VMF7B 39803410 with "Vari modelli". For that code, they mention Ferroli NE Fluss 20 CE, NE Fluss 20 EL PN CE, and NE Fluss 20 PN CE (to be confirmed); please check the serial number. Send us a photo of the rating plate of your boiler via Contact or call 911 17 77 77.
What are the codes 39803410, 38316700, and 38316711?
These are Ferroli codes for a VMF7 PCB. 39803410 is listed as more than and 38316700 is its previous code ("ex") according to 4. Just link 39803410 and 38316700 with the W4115B1317; Not confirmed: 38316711 with it. Provide 38316711 as the original code of the PCB and as "ex": to be confirmed.
Is the W4115B-1317 the same as the W4115B1325 or other W4115B?
without additional confirmation it says. it gives 39803410 with the W4115B1325 (also 1325B or 1325/U); Registered designation: the 1317. There are also the W4115B1192, the W 4115 B 1218B and a modulation PCB w4115b1333u. Compare the suffix of your PCB.
What do W4115B-1317, 963743 1968, and 9640 MF7 mean?
W4115B-1317 is the designation marked on the plate. 963743 1968 and 9640 MF7 are markings that, without further confirmation, explain. The official lists from Ferroli refer to "MF7" (3831670/0, NE 100 PN CE) and "VMF7" (3831671/0, NE FLUSS 24 EL CE) as the plates for those two boilers; none link them to this one. The marked codes do not necessarily correspond to the reference of a kit.
What electrical data is marked on this PCB?
The PCB indicates 230 V 50 Hz and "2AT" as protection. Its transformer shows primary 230 V 50/60 Hz and secondary "SEC24V8VA/18V2VA". These are markings from the photographed unit, not operational measurements.
Who should install this PCB?
It must be installed by a qualified technician. The PCB operates at 230 V and manages the ignition and the gas valve. Before intervening, turn off the power to the boiler and close the gas.
How to identify this PCB?
Compare the silkscreen, the distribution of the connectors, and the exact variant of the circuit with the photographs.

Spare parts related to Honeywell

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Honeywell W4115B-1317 PCB for Gas Boiler