Honeywell PCB S4962V3182V01 · 50075186-004 for Ferroli Bluehelix Tech 25 C and Pro 32C

Honeywell PCB S4962V3182V01 · 50075186-004 for Ferroli Bluehelix Tech 25 C and Pro 32C

Application to the exact variant pending confirmation. It is the PCB of the ABM03 module for the Ferroli Bluehelix Tech 25 C and Pro 32C. The unit with Sw 86656-006 and Cd ABM03B (Tech 25 C) has microcontroller R5F2L3A8CNFP / 522A200 and relay G5NB-1A-E, with silk-screened connectors X1, X2, X3, X4, X5, J1, P1, and P2.

internal SKU
PLC354
Warranty
1 year
VAT included Stock · 1 unit
Compatibility

Honeywell compatible boilers

PCB. 0 verified compatibilities. There are another 5 models that we are still checking.

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Honeywell Ferroli Bluehelix Pro 25 CHoneywellUnconfirmed
Honeywell Ferroli Bluehelix Tech 35 CHoneywellUnconfirmed
Honeywell Ferroli Bluehelix Pro 35 CHoneywellUnconfirmed
Honeywell Ferroli BLUHELIX TECH 25 CHoneywellUnconfirmed
Honeywell Ferroli Bluehelix Pro 32C (ABM03D)HoneywellUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look for the designation S4962V3182V01 and the circuit code 50075186-004 on the PCB.
  2. Note the Sw (86656-006 or 86656-013) and the Cd (ABM03B or ABM03D) of the module. Compare them with those of your PCB.
  3. Do not rely solely on 39845846: ABM03D or ABM03F. The letter of the Cd and the Sw are what need to match.
  4. Check the rating plate of your boiler to see if it is Bluehelix Tech 25 C or Pro 32C, the models that have been registered.
  5. if they match, call us at 911 17 77 77 with your boiler model and we will confirm if we have it available.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is locking up and the burner is not igniting.

    Cause: Lack of gas, dirty or improperly positioned ignition electrode, or faulty gas valve.

    Reset once. If it repeats, have a technician check it.

  • 02

    The boiler locks out without flame just after ignition.

    Cause: Ionization electrode with insertions or improperly placed, or low gas pressure.

    Have a technician check: electrode and gas pressure.

  • 03

    After changing the PCB, the boiler requests calibration (F62) and does not start.

    Cause: The AUTO SETUP calibration is missing after replacing the PCB.

    Perform the AUTO SETUP calibration. If it does not calibrate, have a technician check it.

  • 04

    The boiler is blocked due to an internal fault in the control board (A61, A63).

    Cause: Internal error of the control board or unstable power supply.

    Check the ground connection and the power supply. If the issue persists, have the technician replace the control board.

  • 05

    The boiler stops working after resetting many times in a row (F64 or A64).

    Cause: The maximum number of consecutive resets has been exceeded; it is a protection feature.

    Cut the power for 60 seconds and then restore it. If it returns, have a technician check it.

Honeywell fault codes that require diagnosis

CodeFaultTechnical checks
A01The burner does not ignite.Reset once. If it repeats, have a technician check it: gas, ignition electrode, and gas valve. A guide describes it as the most common blockage in the range.
A02Flame signal present with the burner off.If it repeats, have a technician check: wiring of the ionization electrode and the PCB.
A06There is no flame after the ignition phase.It is usually a dirty or improperly positioned ionization electrode, or low gas pressure. Have a technician check it.
A61Internal error of the control board (ABM03 or AGC01, according to the guide).Check the ground connection. If it persists, have the technician replace the control board. The guides also provide A63, A64, and A65 with the same text.
A62Lack of communication between the control board and the gas valve.Check that the control board is connected to the gas valve. If the issue persists, have the technician replace the valve or check the wiring.
A63Anomaly of the control board: internal error or unstable power supply.Check the power supply. If the issue persists, have the technician replace the control board.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: Honeywell PCB

Uniclima internal SKU
PLC354
Brand
Honeywell
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Inventory — Additional marking
GM-15/13
Inventory — Microcontroller subcomponent
R5F2L3A8CNFP / 522A200
Inventory — Relay subcomponent
G5NB-1A-E
Inventory — Screen-printed connectors
X1, X2, X3, X4, X5, J1, P1, P2
Inventory — Application indicated in inventory
Ferroli BLUHELIX TECH 25 C
Inventory — Marked code
Sw:86656-006; Cd:ABM03B
Data to be confirmed (1 source) — Fuse next to the ABM03B (electrical diagram)
3.15 A · 250 V · Official manual Ferroli Bluehelix Tech C
Identification — Marked designation
S4962V3182V01
Identification — Marked code
Sw:86656-006
Identification — Marked code
ABM03B
Identification — Marked code
1546
Inventory data — Additional marking
GM-15/13
Inventory data — Microcontroller subcomponent
R5F2L3A8CNFP / 522A200
Inventory data — Relay subcomponent
G5NB-1A-E
Inventory data — Screen-printed connectors
X1, X2, X3, X4, X5, J1, P1, P2
Inventory data — Application indicated in inventory
Ferroli BLUHELIX TECH 25 C
Inventory data — Marked code
Sw:86656-006; Cd:ABM03B
Pending applications to verify
Ferroli BLUHELIX TECH 25 C — compatibility noted; pending confirmation by variant.
Before purchasing
  • Ferroli Bluehelix Pro 25 C
  • To confirm: Ferroli Bluehelix Tech 35 C — 1 origin: (module ABM03D)
  • To confirm: Ferroli Bluehelix Pro 35 C — 1 origin: (module ABM03D)
  • Do not confuse: ABM03F — Module letter for 39845846 — This PCB uses Cd ABM03B or ABM03D. Compare Sw and Cd before requesting another version.
  • Do not confuse: S4962V3182 / ABM03E — Honeywell PCB for Bluehelix Pro/Tech with the Ferroli code 39845845 — Without the suffix V01 and with code ABM03E. This PCB carries S4962V3182V01 with code ABM03B or ABM03D.
  • Do not confuse: 38326222 — ABM03B central kit for the Pro 32C (ref. Ferroli 39845842) — This is the name of a kit, not an official breakdown. Registered confirmation: the Pro 32C with Cd ABM03D.
  • 39845846 is the code for the ABM03 module: ABM03D (which is provided as a replacement for the ABM03B) and ABM03F. Without additional confirmation, it is linked to S4962V3182V01, and we have not seen an official breakdown with it.
  • Just combine S4962V3182V01 and 50075186-004 with a Bluehelix (Pro 25 C) and 39845846 as module ABM03D or ABM03F, without the Honeywell code. The official manual only labels ABM03B. Tech 25 C and Pro 32C: registered.
  • Pending registered applications to confirm by model, variant, or programming: Ferroli BLUHELIX TECH 25 C; Ferroli Bluehelix Pro 32C (ABM03D).
Frequently Asked Questions

Frequently asked questions about the PCB (control board)

Where is the code for this PCB and what else should I compare?
The designation S4962V3182V01 and the circuit code 50075186-004 are marked on the board. Also compare the Sw (86656-006 or 86656-013), the Cd (ABM03B or ABM03D), and the marking GM-15/13. Show S4962V3182V01 and 50075186-004 in the technical sheet of a Ferroli Pro 25 C board.
Is it compatible with my Ferroli Bluehelix Tech 25 C?
The compatibility of this variant is pending confirmation. Registered application: the unit with Sw 86656-006 and Cd ABM03B for the Bluehelix Tech 25 C gives the module ABM03D for the Tech 25 C and 35 C, and the official manual of the Tech C labels ABM03B in its electrical diagram.
Is it compatible with the Ferroli Bluehelix Pro 32C?
The compatibility of this variant is pending confirmation. Registered application: the unit with Sw 86656-013 and Cd ABM03D for the Pro 32C. Additionally, title the card ABM03 39845846 as Bluehelix 25C/32C. For spare parts ready for this boiler, a central kit ABM03B (38326222): compare Sw and Cd.
What do ABM03B, ABM03D, and 39845846 mean?
ABM03B and ABM03D are the Cd of the two versions of the module. It gives 39845846 as the ABM03D module, stating that it replaces the ABM03B and lists 39845845, 39845844, 39845842, and 39845843 as original codes. They refer to it as ABM03F (the second one, "EX 39845845"). These are codes.
What is the difference between the unit Sw 86656-006 / ABM03B and the Sw 86656-013 / ABM03D?
It is the same board S4962V3182V01 with PCB 50075186-004, in two module versions. The unit ABM03D has an integrated LCD screen. Registered confirmation: each version for your boiler: compare Sw and Cd before replacing it with the other. It sells an S4962V3182 without V01 with Cd ABM03E (39845845): it is another variant.
Do other Ferroli boilers use the same PCB?
The compatibility of this variant is pending confirmation. It lists the module ABM03D (code 39845846) for the Bluehelix Tech 35 C and the Pro 35 C, but it does not associate that code with the PCB S4962V3182V01: it is a hint, not a confirmation. It provides a PCB with S4962V3182V01 and 50075186-004 for the Pro 25 C. Each one has only one. If in doubt, send us a photo of the label of the PCB and the characteristics plate of your boiler from Contact.
What components does the unit with Sw 86656-006 and Cd ABM03B have?
It carries the microcontroller R5F2L3A8CNFP / 522A200, the relay G5NB-1A-E, and the silkscreened connectors X1, X2, X3, X4, X5, J1, P1, P2. Our inventory does not list these components for the unit Sw 86656-013 / Cd ABM03D. Compare the Sw and Cd of your PCB with those of this one before ordering or replacing it.

Spare parts related to Honeywell

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Honeywell PCB S4962V3182V01 · 50075186-004 for Ferroli Bluehelix Tech 25 C and Pro 32C