
Honeywell PCB S4962V3182V01 · 50075186-004 for Ferroli Bluehelix Tech 25 C and Pro 32C
Application to the exact variant pending confirmation. It is the PCB of the ABM03 module for the Ferroli Bluehelix Tech 25 C and Pro 32C. The unit with Sw 86656-006 and Cd ABM03B (Tech 25 C) has microcontroller R5F2L3A8CNFP / 522A200 and relay G5NB-1A-E, with silk-screened connectors X1, X2, X3, X4, X5, J1, P1, and P2.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- internal SKU
- PLC354
- Warranty
- 1 year
Honeywell compatible boilers
PCB. 0 verified compatibilities. There are another 5 models that we are still checking.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Honeywell Ferroli Bluehelix Pro 25 C | Honeywell | Unconfirmed |
|---|---|---|
| Honeywell Ferroli Bluehelix Tech 35 C | Honeywell | Unconfirmed |
| Honeywell Ferroli Bluehelix Pro 35 C | Honeywell | Unconfirmed |
| Honeywell Ferroli BLUHELIX TECH 25 C | Honeywell | Unconfirmed |
| Honeywell Ferroli Bluehelix Pro 32C (ABM03D) | Honeywell | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the designation S4962V3182V01 and the circuit code 50075186-004 on the PCB.
- Note the Sw (86656-006 or 86656-013) and the Cd (ABM03B or ABM03D) of the module. Compare them with those of your PCB.
- Do not rely solely on 39845846: ABM03D or ABM03F. The letter of the Cd and the Sw are what need to match.
- Check the rating plate of your boiler to see if it is Bluehelix Tech 25 C or Pro 32C, the models that have been registered.
- if they match, call us at 911 17 77 77 with your boiler model and we will confirm if we have it available.
Symptoms that require diagnosis on the PCB
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler is locking up and the burner is not igniting.
Cause: Lack of gas, dirty or improperly positioned ignition electrode, or faulty gas valve.
Reset once. If it repeats, have a technician check it.
- 02
The boiler locks out without flame just after ignition.
Cause: Ionization electrode with insertions or improperly placed, or low gas pressure.
Have a technician check: electrode and gas pressure.
- 03
After changing the PCB, the boiler requests calibration (F62) and does not start.
Cause: The AUTO SETUP calibration is missing after replacing the PCB.
Perform the AUTO SETUP calibration. If it does not calibrate, have a technician check it.
- 04
The boiler is blocked due to an internal fault in the control board (A61, A63).
Cause: Internal error of the control board or unstable power supply.
Check the ground connection and the power supply. If the issue persists, have the technician replace the control board.
- 05
The boiler stops working after resetting many times in a row (F64 or A64).
Cause: The maximum number of consecutive resets has been exceeded; it is a protection feature.
Cut the power for 60 seconds and then restore it. If it returns, have a technician check it.
Honeywell fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| A01 | The burner does not ignite. | Reset once. If it repeats, have a technician check it: gas, ignition electrode, and gas valve. A guide describes it as the most common blockage in the range. |
| A02 | Flame signal present with the burner off. | If it repeats, have a technician check: wiring of the ionization electrode and the PCB. |
| A06 | There is no flame after the ignition phase. | It is usually a dirty or improperly positioned ionization electrode, or low gas pressure. Have a technician check it. |
| A61 | Internal error of the control board (ABM03 or AGC01, according to the guide). | Check the ground connection. If it persists, have the technician replace the control board. The guides also provide A63, A64, and A65 with the same text. |
| A62 | Lack of communication between the control board and the gas valve. | Check that the control board is connected to the gas valve. If the issue persists, have the technician replace the valve or check the wiring. |
| A63 | Anomaly of the control board: internal error or unstable power supply. | Check the power supply. If the issue persists, have the technician replace the control board. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Honeywell PCB
- Uniclima internal SKU
- PLC354
- Brand
- Honeywell
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Inventory — Additional marking
- GM-15/13
- Inventory — Microcontroller subcomponent
- R5F2L3A8CNFP / 522A200
- Inventory — Relay subcomponent
- G5NB-1A-E
- Inventory — Screen-printed connectors
- X1, X2, X3, X4, X5, J1, P1, P2
- Inventory — Application indicated in inventory
- Ferroli BLUHELIX TECH 25 C
- Inventory — Marked code
- Sw:86656-006; Cd:ABM03B
- Data to be confirmed (1 source) — Fuse next to the ABM03B (electrical diagram)
- 3.15 A · 250 V · Official manual Ferroli Bluehelix Tech C
- Identification — Marked designation
- S4962V3182V01
- Identification — Marked code
- Sw:86656-006
- Identification — Marked code
- ABM03B
- Identification — Marked code
- 1546
- Inventory data — Additional marking
- GM-15/13
- Inventory data — Microcontroller subcomponent
- R5F2L3A8CNFP / 522A200
- Inventory data — Relay subcomponent
- G5NB-1A-E
- Inventory data — Screen-printed connectors
- X1, X2, X3, X4, X5, J1, P1, P2
- Inventory data — Application indicated in inventory
- Ferroli BLUHELIX TECH 25 C
- Inventory data — Marked code
- Sw:86656-006; Cd:ABM03B
- Pending applications to verify
- Ferroli BLUHELIX TECH 25 C — compatibility noted; pending confirmation by variant.
- Ferroli Bluehelix Pro 25 C
- To confirm: Ferroli Bluehelix Tech 35 C — 1 origin: (module ABM03D)
- To confirm: Ferroli Bluehelix Pro 35 C — 1 origin: (module ABM03D)
- Do not confuse: ABM03F — Module letter for 39845846 — This PCB uses Cd ABM03B or ABM03D. Compare Sw and Cd before requesting another version.
- Do not confuse: S4962V3182 / ABM03E — Honeywell PCB for Bluehelix Pro/Tech with the Ferroli code 39845845 — Without the suffix V01 and with code ABM03E. This PCB carries S4962V3182V01 with code ABM03B or ABM03D.
- Do not confuse: 38326222 — ABM03B central kit for the Pro 32C (ref. Ferroli 39845842) — This is the name of a kit, not an official breakdown. Registered confirmation: the Pro 32C with Cd ABM03D.
- 39845846 is the code for the ABM03 module: ABM03D (which is provided as a replacement for the ABM03B) and ABM03F. Without additional confirmation, it is linked to S4962V3182V01, and we have not seen an official breakdown with it.
- Just combine S4962V3182V01 and 50075186-004 with a Bluehelix (Pro 25 C) and 39845846 as module ABM03D or ABM03F, without the Honeywell code. The official manual only labels ABM03B. Tech 25 C and Pro 32C: registered.
- Pending registered applications to confirm by model, variant, or programming: Ferroli BLUHELIX TECH 25 C; Ferroli Bluehelix Pro 32C (ABM03D).


