SIT 0585104_13 Electronic Board · PCB 7530197_01 for Biasi Myto Condens 24

SIT 0585104_13 Electronic Board · PCB 7530197_01 for Biasi Myto Condens 24

Application to the exact variant pending confirmation. It is the central electronic control of the boiler: it manages its functions based on thermostats, switches, and sensors. It is suspected if the boiler stops responding, gives errors, or resets.

internal SKU
PLC340
Warranty
1 year
VAT included OUT OF STOCK
Compatibility

Biasi boilers compatible

PCB. 0 verified compatibilities. There are another 10 models that we are still checking.

Models pending verification

These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.

Manaut / Biasi Savio Biasi M160BiasiUnconfirmed
Manaut / Biasi Savio Biasi M260BiasiUnconfirmed
Manaut / Biasi Manaut Myto Condens INOX 24 y 35BiasiUnconfirmed
Manaut / Biasi Manaut Myto Condens 35BiasiUnconfirmed
Manaut / Biasi Biasi M261 y M262BiasiUnconfirmed
Manaut / Biasi Biasi Inovia, Activ A y Advance PlusBiasiUnconfirmed
Manaut / Biasi Biasi T260ABiasiUnconfirmed
Manaut / Biasi Biasi Eiliadens E, Evodens E, Inovia IN E y Rinnova IN EBiasiUnconfirmed
Manaut / Biasi Biasi Activ A Plus y Rinnova Cond X 25SBiasiUnconfirmed
Manaut / Biasi Manaut Myto Condens 24 (registrada como «Myto Condes 24»)BiasiUnconfirmed

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Look for the SIT code 0585104_13 on the label of the PCB and the 7530197_01 on the printed circuit board.
  2. Compare the reference: BI2035100 and 0585104 as the same part; the official breakdowns list BI2035 100 in the control board, without mentioning this PCB.
  3. Look at the suffix: «0585104 15» and none the 13; this unit is the _13 (firmware 214_18).
  4. Check the model on the rating plate: only the Myto Condens 24 is registered.
  5. If they match, call us at 911 17 77 77 with your boiler model and we will tell you if it fits.
Diagnosis and fault codes

Symptoms that require diagnosis on the PCB

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler stops responding, does not ignite, resets, or shows erratic errors on the screen.

    Cause: faults that stop responding, give erratic errors or restart; that do not turn on or do not respond (faults).

  • 02

    The boiler stops responding to the controls.

    Cause: The control PCB may be faulty.

    Check the PCB visually: stuck relays, components with heat marks, or burnt traces on the printed circuit board. Have it done by a qualified technician.

  • 03

    The boiler locks when turned on and no flame is formed (Er01).

    Cause: Ignition fault: gas, electrode, ignition cable or electronics.

    Reset once. If it repeats, have a technician check it.

  • 04

    The boiler locks with Er03 and the lock returns after resetting.

    Cause: Internal fault of the PCB or wiring. Another table shows E03 as EEPROM memory error.

    Reset once; if it returns, have a technician check it (wiring and PCB).

  • 05

    The boiler does not ignite and shows Er01.

    Cause: Flame not detected: lack of gas, faulty ignition or ionization electrode, or gas valve.

    Check the gas supply and press reset once. If it appears again, have a technician check it.

  • 06

    The boiler locks with E01 when turned on.

    Cause: No flame detected during startup.

    Reset once. If it repeats, have a technician check it.

  • 07

    The boiler locks with E02 (safety thermostat).

    Cause: Safety thermostat trip due to overheating or thermal protection.

    Reset once. If it blocks again, have a technician check it.

  • 08

    The boiler locks up when starting.

    Cause: It does not detect flame during startup.

    Reset once. If it repeats, have a technician check it (gas, electrode, and wiring).

  • 09

    11E appears with the burner off.

    Cause: The electronics detect flame when it shouldn't.

    Have a technician check: ionization electrode, cable, and then the PCB.

  • 10

    Lockout with Er 06; the boiler measures the flow temperature incorrectly.

    Cause: Faulty NTC sensor on the supply line or with a bad connector.

    First, check the connector and the cable; then, the sensor. Have a technician check it.

  • 11

    Lockout with Er 07 (domestic hot water sensor).

    Cause: Faulty or disconnected domestic hot water sensor.

    Check the connector, cable, and domestic hot water sensor. Have a technician inspect it.

  • 12

    The boiler locks without igniting and shows E01.

    Cause: Safety lock due to ignition failure.

    Press the reset once. If it repeats, have a technician check it.

  • 13

    The display shows E06, E07, or E08 (NTC sensors).

    Cause: NTC sensor faulty or no signal.

    Have a technician check it.

  • 14

    The display shows E11 (parasitic flame).

    Cause: Flame detected without the boiler having ignited it.

    Have a technician check it.

  • 15

    The boiler locks up when turned on and shows Er01 (01E with remote control).

    Cause: Ignition fault, according to the series table.

    Reset once. If it repeats, have a technician check it.

  • 16

    The boiler locks up when turned on and shows E01.

    Cause: No flame detected during startup.

    Reset once. If it blocks again, have a technician check it.

  • 17

    The display shows E06, E07, or E08 and the temperature indicated is not reliable.

    Cause: The PCB receives an incorrect reading from an NTC sensor.

    Have a technician check it: verify sensors and wiring before replacing the PCB.

  • 18

    The display shows E05 and the fan is not working properly.

    Cause: Fan control anomaly: the fan does not spin properly or does not communicate with the PCB.

    Have a technician check it. Do not tamper with the flue gas evacuation on your own.

  • 19

    The display shows E11 with the burner off.

    Cause: The electronics detect flame when it shouldn't.

    Have a technician check it: the PCB and the flame system are the points to look at.

Fault codes Manaut / Biasi that require diagnosis

CodeFaultTechnical checks
Er01Safety lockout due to ignition failure.Reset once. If it repeats, have a technician check it (gas, electrode, ignition cable). Other guides refer to it as E01.
Er06Fault of the heating NTC sensor (flow).Point to the sensor and its connection to the PCB. Have a technician check it. Other guides refer to it as E06.
Er07Fault of the NTC sensor for domestic hot water.Point to the domestic hot water sensor and its connection. Have a technician check it. Other guides refer to it as E07.
E01Safety lockout due to ignition failure.Reset once. If it repeats, have a technician check it: it points to the ignition or the flame.
E02Lockout due to safety thermostat trip.Reset once. If it blocks again, have a technician check it.
E06Fault of the heating flow NTC sensor.Have a technician check it: it points to the sensor or its wiring.
11EParasitic flame: the electronics detect flame with the burner off.It appears like this on the remote control. Have a technician check: ionization electrode, cable, and then the PCB.
E07Fault of the domestic hot water NTC sensor.Have a technician check it. If the sensor continues to malfunction, it points to the PCB.
E08Fault of the external NTC sensor.It only appears with an external sensor configured. Have a technician check it.
E09Fault of the flue gas NTC sensor (interruption).Have a technician check it. It is a safety sensor for the flue.
E10Lockout due to intervention of the flue sensor.If it repeats, have it checked by an authorized technician.
E11Flame detected when the boiler should not have one.Have a technician check it. Focus on the flame electronics.
E12Fault of the heating return NTC sensor.Have a technician check it: first the sensor and cable. If the issue persists, it points to the PCB.
E05Fan control anomaly.Have a technician check it. If the fan is spinning properly and the fault code persists, the PCB is the suspect.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: PCB (control board) Biasi

Uniclima internal SKU
PLC340
Brand
Biasi
Type of part
PCBs (control boards)
Units in stock
0 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Firmware of the PCB
214_18
CE marking printed on the label of the PCB
0085BU0057
Additional markings on the label
14064.1208.9; 1545 BV07258
Relay mounted on the PCB
G5NB-1A-E; coil: 24 VDC; contact: 5 A 250 VAC~
Microcontroller of the PCB
PIC24FJ256GA106
Condenser marking
511 / 330 / 35 V
Source of additional data
Declared information; auxiliary references and applications without equivalent from the accredited manufacturer.
Inventory — Subcomponent condenser
marked 511 / 330 / 35 V
Inventory — Marked code
214_18; 14064.1208.9; 1545 BV07258; 08872598
Registered reference
7530197_01
Registered model
0585104_13
Additional markings
Label/variant of PCB: 0585104_13; PCB silkscreen: 7530197_01. CE PIN: 0085BU0057. Relay G5NB-1A-E: coil 24 VDC; contact 5 A / 250 VAC. Microcontroller PIC24FJ256GA106. Capacitor marked 511 / 330 / 35 V. Codes: 214_18; 14064.1208.9; 1545 BV07258; 08872598.
Pending applications to verify
Biasi MYTO CONDES 24 — noted compatibility; pending confirmation by variant. Registered application: Myto Condens INOX24; this commercial application does not alone resolve the firmware difference.
Before purchasing
  • To confirm: Savio Biasi M160 — (BI2035100); none mention the suffix _13.
  • To confirm: Savio Biasi M260 — Official breakdown from Biasi and at least; none mention the suffix _13.
  • To confirm: Biasi Myto Condens INOX 24 and 35 — plus (possibly the same group as, not verified); Biasi catalog: only BI2035 100 in the control panel, model table not read.
  • To confirm: Biasi Myto Condens 35 — (BI2035100, in lists "24/35"), perhaps from the same group as (not verified)
  • To confirm: Biasi M261 and M262
  • To confirm: Biasi Inovia, Activ A, and Advance Plus — British (BI2035100); Activ A, too.
  • To confirm: Biasi T260A. The title mentions T260; a reading of its list includes T260A, unconfirmed.
  • To confirm: Biasi Eiliadens E, Evodens E, Inovia IN E, and Rinnova IN E — clear. List them in a reading, with registration control, without confirmation.
  • To confirm: Biasi Activ A Plus and Rinnova Cond X 25S — each one.
  • Do not confuse: 0585104 15 — SIT PCB with suffix 15 and firmware FW.214 20, according to — This unit has suffix _13 and firmware 214_18; it is not stated whether they are interchangeable.
  • join SIT 0585104 with BI2035100 and two official breakdowns list BI2035 100 without naming the part, but none mention the suffix _13: it gives "0585104 15" and the label says 0585104_13.
  • Pending registered applications to confirm by model, variant, or programming: Biasi Myto Condens 24 (registered as "Myto Condes 24").
Frequently Asked Questions

Frequently asked questions about the PCB (control board)

How do I identify the SIT 0585104_13 PCB?
Look for the code 0585104_13 on the label and, in the circuit, the 7530197_01. This unit also includes 14064.1208.9, 1545 BV07258, and 0085BU0057.
Is it compatible with my Biasi Myto Condens 24?
The compatibility of this variant is pending confirmation. Registered: for the Biasi Myto Condens 24. It is listed with BI2035100, and a fourth one is to be confirmed; none mention the suffix _13. For another model, call 911 17 77 77.
Is it compatible with a Myto Condens INOX 24, INOX 35 or 35?
The compatibility of this variant is pending confirmation. They are not confirmed. INOX 24 and 35: with BI2035100 and a third one to be confirmed; Myto Condens 35: plus that same one. The official catalog of Biasi (INOX) lists BI2035100 in the control board, without naming the part. Send us a photo of the label from Contact or call 911 17 77 77.
What is the relationship between 0585104, 7530197_01, and BI2035100?
0585104 is the SIT code for the PCB and 7530197_01 is the code for its printed circuit. BI2035100 is the spare part reference provided along with SIT 0585104; the breakdowns from Biasi and Baxi Roca list BI2035 100 in the control panel, without naming the part.
Is the 0585104_13 the same as the 0585104 15?
We don't know. Describe a PCB 0585104 15 (FW.214 20, 14064.1208.9); this unit is the 0585104_13 (214_18) and also carries 14064.1208.9. Not confirmed: if they are interchangeable; if the suffix does not match, please consult us.
What other boilers use this PCB?
The compatibility of this variant is pending confirmation. According to the parts lists, BI2035100 also appears for Biasi M160, M260 (official parts list from Biasi and at least), M261 and M262 (3), Inovia, Activ A, and Advance Plus (British models). All to be confirmed: none mention the suffix _13.
What symptoms indicate this PCB and who should replace it?
faults that stop responding, give erratic errors or restart; that do not turn on or do not respond. These are faults, not from an official table. Have it assembled by a qualified technician (gas appliance).
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts