PCB Baxi Roca 1271002190 · E961077E for Neobit 24/24 F
Pending confirmation for the exact variant. To be confirmed: It is the PCB of the boiler. It is located behind the front panel, in the control box, and it is suspected if the boiler does not ignite or does not respond to the panel, restarts continuously, or relay clicks are heard.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- internal SKU
- PLC123
- Warranty
- 1 year
Compatible Baxi Roca boilers
PCB. 0 confirmed compatibilities. There are another 7 models that we are still verifying.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Baxi Roca Neobit 24/24 F R | Baxi Roca | Unconfirmed |
|---|---|---|
| Baxi Roca Neobit Plus 24/24 F R | Baxi Roca | Unconfirmed |
| Baxi Roca Roca Ecobit 24/24 F | Baxi Roca | Unconfirmed |
| Baxi Roca Roca Ecobit 24/24 F R | Baxi Roca | Unconfirmed |
| Baxi Roca Ecobit Compact 24/24 F | Baxi Roca | Unconfirmed |
| Baxi Roca Roca Sara 24/24 F | Baxi Roca | Unconfirmed |
| Baxi Roca Neobit 24/24 F | Baxi Roca | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Please confirm: Look for 1271002190 on the PCB: it usually says it is screen printed on the circuit or on a side sticker.
- Also compare the circuit E961077E and those marked ECOBIT FF, 9555516800C, U3 961079R, and U4 961080A-3.
- Compare the number and position of the relays and connectors: the same reference has different versions.
- Do not confuse it with 122123620 (Neobit 24/24 without F) or with 125566966 (Neobit S 24/24 F).
- if they match, call us at 911 17 77 77 with the model of your boiler.
Symptoms that require diagnosis on the PCB
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite or respond to any commands from the front panel.
Cause: To confirm: It is associated with this PCB.
- 02
Continuous resets in heating or domestic hot water.
Cause: Also relate it to this PCB; have a technician confirm it.
- 03
Strange clicks or stuck relays in the circuit.
Cause: Stuck relay signal.
- 04
The boiler does not ignite and locks with pilots 60, 70, and 90 lit.
Cause: Lack of gas or spark in the ignition.
Check that gas is reaching and that the valve is open. If it happens again, have a technician check the ignition and the PCB.
- 05
The boiler does not ignite and several temperature LEDs remain lit along with the fault LED (60-70-90 or 40-80-90).
Cause: There is no gas reaching the boiler or there is no ignition spark.
Check that the gas shut-off valve is open. If it still doesn't ignite, have a technician check it.
- 06
The boiler is locked with LEDs 50 and 90 lit along with the anomaly LED.
Cause: Faulty heating sensor or damaged sensor cable.
Have a technician check it: the sensor and its cable are inside the boiler.
Fault codes Baxi Roca that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| 60-70-90 | Ignition lock: the burner does not ignite due to lack of gas or spark. | Check that gas is arriving and that the valve is open. If it repeats, have a technician check the ignition; point to the PCB if the gas and spark are fine. |
| 40-80-90 | Gas shortage with the boiler in operation, or total or partial electrical failure. LEDs 40, 80, and 90 light up along with the anomaly LED. | Check that gas is arriving (shut-off valve open). If it repeats, have a technician check it: it may be on the PCB. |
| 60-90 | The flame relay is faulty or turned off. LEDs 60 and 90 light up along with the anomaly LED. | If the flame does not stay on even though gas is reaching it, have a technician check it: it points to the PCB. |
| 50-90 | Heating sensor faulty or with damaged cable. LEDs 50 and 90 light up along with the fault LED. | Have a technician check it: the sensor and its cable are inside the boiler. It points to the PCB, which is the one that reads the sensor. |
| 40-60-90 | Fault in the safety circuit. LEDs 40, 60, and 90 light up along with the anomaly LED. | Reset the boiler once. If it blocks again, have a technician check it: it points to the PCB. |
| 70-90 | Safety fuse open. LEDs 70 and 90 light up along with the fault LED. | The fuse should be replaced by a technician, who must also investigate the cause, as it may happen again. |
| 40-70-90 | Gas solenoid valve power failure. LEDs 40, 70, and 90 light up along with the fault LED. | Reset and check that gas is reaching. If it repeats, have a technician check it: it points to the PCB or the power supply to the gas valves. |
| 50-70-90 | The safety relay does not close after the heat demand. LEDs 50, 70, and 90 light up along with the fault LED. | Have a technician check it: it points to the PCB, which controls the safety relay. |
| 40-50-70-90 | The burner shuts off because the ignition time is too short. LEDs 40, 50, 70, and 90 light up along with the anomaly LED. | Reset once. If it repeats, have a technician check it: it points to the PCB, which manages the timing. |
| 40-60-70-90 | The burner shuts off because the ignition time is too long. LEDs 40, 60, 70, and 90 light up along with the anomaly LED. | Reset once. If it repeats, have a technician check it: it points to the PCB, which manages the timing. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi Roca PCB.
- Uniclima internal SKU
- PLC123
- Brand
- Baxi Roca
- Type of part
- PCBs (control boards)
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Marked fuse
- 2 A
- Another marked fuse
- 3.15 A
- Visible switch
- six-position DIP switch; non-prescribed adjustment
- Inventory — Fuse
- 2 A; format 5×20
- Inventory — DIP Switch
- 6 positions
- Inventory — Terminals
- +VCC and GND
- Inventory — Omron G2R-2 relay subcomponent
- 12 VDC coil
- Inventory — Transformer subcomponent
- marked T18
- Inventory — Application indicated in inventory
- ROCA NEOBIT 24/24 F
- Inventory — Marked code
- 1271002190; ECOBIT FF; 0612
- To confirm: Location
- Behind the front panel, in the control box
- Identification — Marked code
- 1271002190
- Identification — Marked code
- ECOBIT FF
- Identification — Marked code
- 9555516800C
- Identification — Marked code
- E961077E
- Identification — Marked code
- U3 961079R
- Identification — Marked code
- U4 961080A-3
- Identification — Marked code
- 0612
- Technical sheet: Marked fuse
- 2 A
- Technical sheet: Another marked fuse
- 3.15 A
- Visible switch
- six-position DIP switch; non-prescribed adjustment
- Inventory data — Fuse
- 2 A; format 5×20
- Inventory data — DIP switch
- 6 positions
- Inventory data — Bornes
- +VCC and GND
- Inventory data — Omron G2R-2 relay subcomponent
- 12 VDC coil
- Inventory data — Transformer subcomponent
- marked T18
- Inventory data — Application indicated in inventory
- ROCA NEOBIT 24/24 F
- Inventory data — Marked code
- 1271002190; ECOBIT FF; 0612
- Pending applications to verify
- Existing transcription in "Compatibilities"; it has not been documented validated in this update and should not be treated as verified compatibility: ROCA NEOBIT 24/24 F declares for its product 10360 ("PCB (control board) Roca (9555516800C) [122123660]"): Neobit 24/24 F-B; Neobit 28/28 F; Sara 20/20 F; Sara 20/20 F-B; Sara 24/24 F; Sara 24/24 F-B; Sara 28/28 F. Pending verification with manufacturer documentation for the reference and physical variant; this commercial statement does not certify compatibility or interchangeability.
- The symptoms are given by just one. Have a technician confirm the diagnosis before replacing the PCB.
- To confirm: Baxi Roca Neobit 24/24 F R
- To confirm: Baxi Roca Neobit Plus 24/24 F R
- To confirm: Baxi Roca Ecobit 24/24 F
- To confirm: Baxi Roca Ecobit 24/24 F R
- To confirm: Baxi Roca Ecobit Compact 24/24 F
- To confirm: Baxi Roca Sara 24/24 F
- Not compatible or excluded: Baxi Roca Neobit 24/24 (without F) — It has a different PCB: 122123620
- Not compatible or excluded: Baxi Roca Neobit S 24/24 F — It has a different PCB: 125566966. Only replaced by 125568548.
- Not compatible or excluded: Baxi Roca Neobit Plus 24/24 F — Another PCB according to: 125128870; it is compatible.
- Not compatible or excluded: Baxi Roca Nora 24/24 F — Another PCB: 122123640; it is compatible.
- Do not confuse: 122123620 — PCB of the Neobit 24/24 (without F), it is not interchangeable with 1271002190.
- Do not confuse: 125566966 — PCB for the Neobit S 24/24 F — for that boiler; one says it is not interchangeable.
- Do not confuse: 125568548 — PCB that replaces 125566966; without additional confirmation it links to 1271002190.
- Do not confuse: 125568739 — Honeywell card for Victoria 24 / Neobit 24 — According to the blog; without additional confirmation, it links to 1271002190.
- the PCB of the Neobit 24/24 F like Baxi Roca 122123680, but none links it to 1271002190: it is not considered equivalent.
- To confirm: 1271002190 and E961077E, marked on the plate. The rest; Neobit S 24/24 F, another plate. Neobit Plus and Nora 24/24 F: another has another plate (contradiction). 122123680 without linking it to 1271002190. We did not find an official parts breakdown.
- Pending confirmation of registered applications by model, variant, or programming: Baxi Roca Neobit 24/24 F.