SIT La Precisa 7530130_00 PCB for Viessmann Vitopend 100 WH0A
Application to the exact variant pending confirmation. PCB of the boiler, with an integrated transformer (primary 230 V, secondary 15 V). Before suspecting it, a qualified technician must check the power supply and the connections.
- Type of part
- PCBs (control boards)
- Status
- Refurbished
- internal SKU
- PLC294
- Warranty
- 1 year
SIT LA PRECISA compatible boilers
PCB. 0 verified compatibilities. There are another 1 models that we are still checking.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Viessmann Vitopend 100 WH0A | SIT the precise | Unconfirmed |
|---|
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the code 7530130_00 (also written as 7530130-00) on the label. It is the main identifier.
- Check that it also includes 0580118-(03), 9571588, and 4169C, and the marking 384_03 on the integrated circuit. If any are missing or differ, it may be another variant.
- Look at the integrated transformer: it should say PRI 230 Vac 50 Hz and SEC 15 Vac 12 VA.
- If your current PCB has 7827494 instead of 7530130_00, do not assume that it is the same: without additional confirmation, we have read both codes.
- Check on the rating plate that your boiler is a Viessmann Vitopend 100 WH0A, the one you have registered.
- if they match, call us at 911 17 77 77 with the model of your boiler.
Symptoms that require diagnosis on the PCB
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and shows F4.
Cause: No flame on startup: lack of gas, frozen condensate, or ignition failure.
Check the gas supply and reset once. If it repeats, have a technician check it.
- 02
The boiler shows F30 or F38 (temperature sensor).
Cause: Boiler sensor short circuit (F30) or open circuit (F38): fault of the sensor or its cable.
Reset it once. If it appears again, have a technician check it.
- 03
The boiler shows F50 (domestic hot water sensor).
Cause: Short circuit of the domestic hot water temperature sensor.
Reset it once. If the issue persists, have a technician check it.
Códigos de error SIT LA PRECISA que requieren diagnóstico
| Code | Fault | Technical checks |
|---|---|---|
| F4 | No flame signal when starting the burner. | Check the gas supply and reset once. If it repeats, have a technician check it: it could be the ignition, the electrode, or the PCB. |
| F30 | Short circuit in the temperature sensor of the boiler. | Reset it once. If it appears again, have a technician check it: it is usually the sensor or its cable. |
| F38 | Temperature sensor of the boiler open or damaged. | Reset it once. If it appears again, have a technician check it: it is usually the sensor or its cable. |
| F50 | Short circuit in the domestic hot water temperature sensor. | Reset it once. If the issue persists, have a technician check it: it is usually the sensor or its cable. |
| F58 | Open or faulty cylinder temperature sensor. | Have a technician check it: it is usually the sensor or its cable. |
| F59 | Breakage of the domestic hot water outlet temperature sensor. | Have a technician check it: it is usually the sensor or its cable. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: SIT LA PRECISA
- Uniclima internal SKU
- PLC294
- Brand
- SIT THE ACCURATE
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Material/class marking of the PCB
- WK 2 94V-0
- Marked code
- 0580118-(03); 9571588; 4169C; 0612; 17826; 957158817826061203
- Integrated circuit marking
- 384_03
- Integrated transformer (subcomponent)
- PRI 230 Vac 50 Hz; SEC 15 Vac 12 VA
- Maximum operating temperature marked
- 130 °C
- Identification — Marked code
- 7530130_00
- Identification — Marked code
- 0580118-(03)
- Identification — Marked code
- 9571588
- Identification — Marked code
- 4169C
- Identification — Marked code
- 0612
- Identification — Marked code
- 17826
- Identification — Marked code
- 384_03
- Technical sheet: Marking of material/class of the PCB
- WK 2 94V-0
- Technical sheet: Marked code
- 0580118-(03); 9571588; 4169C; 0612; 17826; 957158817826061203
- Marked circuit integrated
- 384_03
- Integrated transformer (subcomponent)
- PRI 230 Vac 50 Hz; SEC 15 Vac 12 VA
- Technical sheet: Maximum operating temperature marked
- 130 °C
- Additional markings
- Marked material/class: WK 2 / 94V-0. Codes: 0580118-(03); 9571588; 4169C; 0612; 17826; 957158817826061203. CI: 384_03. Integrated transformer: PRI 230 Vac / 50 Hz; SEC 15 Vac / 12 VA. Maximum operating temperature marked: 130 °C.
- Pending applications to verify
- Viessmann Vitopend 100 WH0A — compatibility noted; pending confirmation by variant.
- Do not confuse: 7827494 — Viessmann order code for the PCB (or "Regelung") of the Vitopend 100 WH0A or WH0 — No documentation links it to 7530130_00. We do not claim that it is the same part: compare the markings on your PCB.
- Do not confuse: 7832971 · 7831047 — Viessmann codes that, along with 7827494, are for the Vitopend 100 WHKB VMC (7832971) and the Vitopend 100 (7831047) — These are codes for other boilers. Without additional confirmation, they are linked to 7530130_00 and this PCB is not confirmed for them.
- Codes marked on the board itself and registered. They are not necessarily the reference of a manufacturer's kit nor do they certify compatibility with other variants.
- Part, codes, and boiler registered. No external page opened (30 consulted) mentions 7530130_00 or 0580118-(03).