Saunier Duval SYMSI 7.0 PCB · 0310144400P16 for Themafast F25 E H-MOD
To confirm: It is the control board of the boiler: it is responsible for ignition, modulation, safety, and temperature management. It is suspected if the boiler does not ignite or respond, restarts, or shows faults without a physical cause.
- Type of part
- Saunier Duval
- Status
- Refurbished
- internal SKU
- PLC097
- Warranty
- 1 year
Compatible Saunier Duval boilers
Saunier Duval. Four confirmed compatibilities: Saunier Duval Themafast F25 E H-MOD and Saunier Duval Themaclassic F25E. There are another 4 models that we are still verifying.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Themafast F25 E H-MOD | Saunier Duval | Contrasted |
| Saunier Duval Themaclassic F25E | Saunier Duval | Contrasted |
| Saunier Duval Themafast C 25 E | Saunier Duval | Contrasted |
| Saunier Duval F1LA | Saunier Duval | Contrasted |
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Saunier Duval Themafast F 30 E H-MOD | Saunier Duval | Unconfirmed |
|---|---|---|
| Saunier Duval Themafast F 24 E | Saunier Duval | Unconfirmed |
| Saunier Duval Themaclassic C 24 E, C 25 E, F 24 E and AS 24/25/30 E | Saunier Duval | Unconfirmed |
| Saunier Duval Themafast F25E and F30E | Saunier Duval | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look for the silkscreen 0310144400P16 and the designation SYMSI7.0 (or SYMSI 7.0) in the circuit.
- To confirm: 0310144400N14 and 0310144400015 are other versions, not this one. 0310144400T01 appears alongside S10470 and does not connect to the P16.
- Count the relays and check their position and that of the connectors: under the same code there are different versions.
- Look at the model on your boiler's PCB. Confirmed: Themafast F25 E H-MOD, C 25 E, Themaclassic F25E and F1LA. Unconfirmed: Themafast F 24 E and F 30 E H-MOD.
- If they match, call us at 911 17 77 77 with the model of your boiler.
Symptoms that require diagnosis in the Saunier Duval.
Common symptoms and faults
- 01
The boiler does not ignite or respond to any commands.
Cause: it is associated with the SYMSI 7.0 PCB of the Themafast.
- 02
Errors on the screen without a physical cause or restarts in the middle of a heating cycle.
Cause: According to that, they may come from the PCB.
- 03
Stuck relays, burnt tracks or oxidation in the circuit.
Cause: They can be seen when looking at the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Saunier Duval
- Uniclima internal SKU
- PLC097
- Brand
- Saunier Duval
- Type of part
- Saunier Duval
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Terminal silkscreen
- TA 230V; ALIM 230V
- Inventory — Subcomponent relay
- FINDER 40.52
- Inventory — Subcomponent relays
- OMRON
- Inventory — Application indicated in inventory
- THEMAFAST F25 E H-MOD
- Additional information — Power supply
- 230 V · 50 Hz · Heating and Air Conditioning · P16 V1
- Additional information — Relays
- 4 (version P16 V1) · Heating and Air Conditioning
- Identification — Marked code
- 0310144400P16
- Identification — Marked code
- APC 6b 94V-0
- Technical sheet: Terminal screen printing
- TA 230V; ALIM 230V
- Inventory data — Subcomponent relay
- FINDER 40.52
- Inventory data — Subcomponent relays
- OMRON
- Inventory data — Application indicated in inventory
- THEMAFAST F25 E H-MOD
- Registered model
- SYMSI7.0
- To confirm: Saunier Duval Themafast F 30 E H-MOD —, with the P16 (the list is the same for the 015), with S10470 or N14.
- To confirm: Saunier Duval Themafast F 24 E — it is provided with the P16 (and repeats the list for the 015). Heating and Air Conditioning also mentions "F 24 E" with the P16, but in a general list without family: it doesn't count. (S10470) and (N14), with other codes.
- To confirm: Saunier Duval Themaclassic C 24 E, C 25 E, F 24 E and AS 24/25/30 E — with SYMSI 7.0:; gives S10470
- To confirm: Saunier Duval Themafast F25E and F30E — with SYMSI 7.0: (P16) and (N14)
- Do not confuse: 0310144400N14 — Another version SYMSI 7.0, which is compatible with Themafast F24 E, F25 E H-MOD and F30 E H-MOD — Different termination: compare relays and connectors.
- Do not confuse: 0310144400015 — Version V4 with 3 relays (2+1), according to Heating and Air Conditioning — It is not the P16: the P16 V1 has 4 relays.
- 0020021125 and SD00081C come from the label of a unit; they are not mentioned.
- and they join the P16 with the SYMSI 7.0 from Saunier Duval. Without official breakdown and with other versions (N14, 015): compare the code in the unconfirmed boilers.