Saunier Duval PM-02 PCB · 0020183525 / 0020106661 · Thema NOx F25 B
To confirm: It is the control board of the boiler: it manages ignition, modulation, safety features, and communication. It is suspected if it does not ignite, restarts by itself, or shows nonsensical faults.
- Type of part
- Saunier Duval
- Status
- Refurbished
- internal SKU
- PLC032
- Warranty
- 1 year
Compatible Saunier Duval boilers
Saunier Duval. Three confirmed compatibilities: Saunier Duval Themafast NOx F30/B-2 and Saunier Duval Thema NOx F25 B. There are another 12 models that we are still verifying.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval Themafast NOx F30/B-2 | Saunier Duval | Contrasted |
| Saunier Duval Thema NOx F25 B | Saunier Duval | Contrasted |
| Saunier Duval Themafast NOx F30 | Saunier Duval | Contrasted |
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Saunier Duval Themafast NOx F25 A | Saunier Duval | Unconfirmed |
|---|---|---|
| Saunier Duval Themafast NOx F30 NL/LL | Saunier Duval | Unconfirmed |
| Saunier Duval Micraplus NOx 24 B2 | Saunier Duval | Unconfirmed |
| Saunier Duval Thema NOx F25B/2 | Saunier Duval | Unconfirmed |
| Saunier Duval Thema NOx F25 B GN/BP | Saunier Duval | Unconfirmed |
| Saunier Duval Themafast NOx F30 B/1 | Saunier Duval | Unconfirmed |
| Saunier Duval Thema NOx F30 | Saunier Duval | Unconfirmed |
| Saunier Duval Eura 3 30 SE Low NOx | Saunier Duval | Unconfirmed |
| Saunier Duval Micra 3 24 SE Low NOx | Saunier Duval | Unconfirmed |
| Saunier Duval Micraplus NOx 25 | Saunier Duval | Unconfirmed |
| Saunier Duval Themaclassic 2 | Saunier Duval | Unconfirmed |
| Saunier Duval Thema NOx F25 B1 (Themanox F25 B1) | Saunier Duval | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Check the PCB 0020183525 or 0020106661 and the designation PM-02, and compare them with your PCB.
- Compare the marked code next to it: 3512 0309 G with 0020183525, 1453 5079 G with 0020106661.
- Check that the relays and connectors match in number and position with those on your PCB.
- Do not confuse it with S1047000 (Themafast F 30 E H-MOD), 288.00.0008 (Thema NOx F24) or 0010028086 (Vaillant).
- If they match, call us at 911 17 77 77 with the model of your boiler.
Symptoms that require diagnosis in the Saunier Duval.
Common symptoms and faults
- 01
The boiler does not ignite, the burner does not start, it restarts by itself or shows meaningless errors.
Cause: that does not turn on; adds resets and nonsensical errors. It is not an official table.
- 02
Temperature regulation faults or unexpected shutdowns.
Cause: They are being cited.
- 03
Burnt components or traces or oxidation on the PCB.
Cause: It quotes you.
- 04
The boiler does not ignite: the fault code F28 appears (ignition fault).
Cause: Failed ignition: it could be gas, ignition, electrode, or PCB.
Have a technician check it.
- 05
The boiler shuts down during operation and does not restart (fault code F29).
Cause: Gas cut-off, flue gas recirculation, condensates, or faulty grounding.
Have a technician check it.
- 06
The boiler does not ignite or turns off during operation and does not ignite again (fault codes F28 or F29).
Cause: Ignition fault: it may be due to lack of gas, gas meter, ignition or PCB.
Put the boiler out of service, wait 5 seconds, and then restart it. If the issue persists, have it checked by the official SAT.
- 07
The red pilot light is flashing and a fault code F followed by a number appears on the screen: the boiler stops due to an anomaly.
Cause: The PCB has detected an anomaly. The number indicates which one: ignition, flue, sensors, or circulation.
Reset it: turn off the boiler, wait 5 seconds, and turn it back on. If the fault persists, have it checked by the official technical service.
- 08
The boiler does not ignite: after several attempts, it shows a fault with F28 or F29.
Cause: Ignition fault; the source mentions ignition or ionization electrodes.
Check that the gas valve is open and reset once. If it fails again, have a technician check it.
Fault codes Saunier Duval that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F00 | Return temperature sensor (NTC2) disconnected. | Check if the sensor connector is loose. If it persists, have a technician check it: it could be the sensor, the cable, or the PCB. |
| F01 | Return temperature sensor (NTC5) disconnected. | Just like the F00: check the connector and, if it persists, have a technician check it. |
| F27 | Flame detection fault: the flame control is not reliable. | If it occurs when turning on or off, have a technician check it: it could be moisture in the electronics or the flame control. |
| F28 | Ignition fault: the burner does not ignite. | If it repeats, have a technician check it: it could be the gas, the ignition, or the PCB. |
| F29 | Flame loss during operation. | If it repeats, have a technician check it: it could be a gas cut-off, flue gas recirculation, or a faulty ground connection. |
| F61 | Gas valve activation fault. | Have a technician check it: it could be the wiring of the gas valve, its coils, or the electronics. |
| F62 | The gas valve does not close in time after the flame goes out. | Have a technician check it: the gas valve or the PCB are the suspects. |
| F15 | Flame detection fault: there is a flame with the burner off. | If it occurs when turning off or on, have a technician check it: it points to the PCB or the flame control. |
| F5 | Fault of the heating flow sensor (NTC2). | Check if the sensor connector is loose. If it persists, have a technician check it: it could be the sensor, the cable, or the PCB. |
| F1 | Ignition fault, possible gas supply issue (in Themafast C; in NOx it appears as F28 or F29). | Put the boiler out of service, wait 5 seconds, and then restart it. If the issue persists, have a technician check it. |
| F20 | Overheating: the boiler protects itself from excessive heat. | Have a technician check it: verify the circulation and the temperature limiter. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Saunier Duval
- Uniclima internal SKU
- PLC032
- Brand
- Saunier Duval
- Type of part
- Saunier Duval
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Inventory — Indicated brand
- V-Group
- Inventory — Indicated reference
- 0020135165
- Inventory — Application indicated in inventory
- SAUNIER THEMANOX F25 B1
- Inventory — Brand/manufacturer printed on PCB
- V-Group
- Inventory — Exit
- 230 V
- Inventory — Main supply
- 230 V
- Inventory — Relay circuit
- 230 V
- Inventory — Low voltage
- 24 V
- Inventory — Zettler Relay
- 8 A, 250 VAC / 30 VDC
- Inventory — Fuse
- T2A, 250 V
- Inventory — Varistor
- S10 K275
- Inventory — Condenser
- 68 nF, 305 V~
- Inventory — PCB Material
- 94V-0
- Inventory — Marked code
- 0020106661; 1453 5079 G
- Identification — Marked designation
- PM-02
- Identification — Marked code
- 0020106661
- Identification — Marked code
- 1453 5079 G
- Identification — Marked code
- TL-AE
- Inventory data — Indicated brand
- V-Group
- Inventory data — Indicated reference
- 0020135165
- Inventory data — Application indicated in inventory
- SAUNIER THEMANOX F25 B1
- Inventory data — Brand/manufacturer printed on the PCB
- V-Group
- Inventory data — Output
- 230 V
- Inventory data — Main power supply
- 230 V
- Inventory data — Relay circuit
- 230 V
- Inventory data — Low voltage
- 24 V
- Inventory data — Zettler relay
- 8 A, 250 VAC / 30 VDC
- Inventory data — Fuse
- T2A, 250 V
- Inventory data — Varistor
- S10 K275
- Inventory data — Condenser
- 68 nF, 305 V~
- Inventory data — PCB material
- 94V-0
- Inventory data — Marked code
- 0020106661; 1453 5079 G
- Registered reference
- Label: 0020106661
- Identification and equivalences
- Label 0020106661; PCB PM-02 / TL-AE, V-Group. The previous 0020135165 remains as an unconfirmed commercial reference for this unit.
- Additional markings
- Model PM-02; screen-printed brand V-Group. Codes 0020106661; 1453 5079 G; PCB TL-AE. PCB material 94V-0. Components/rating: Zettler relay 8 A, 250 VAC / 30 VDC; fuse T2A/250 V; varistor S10 K275; capacitor 68 nF/305 V~.
- Pending applications to verify
- Saunier Duval THEMANOX F25 B1 — compatibility mentioned, pending validation by variant. commercial 2025–2026, PDF page 217: IDENTITY CONFLICT: assigns 0020135165 to Vaillant VM386/5-5R4 and VMW306/5-5 (art.288.60.0030). ThemanoxF25B1 and the photographed PCB PM-02/0020106661 are not confirmed. The reference field code needs resolution; do not use this match for price or compatibility.
- To confirm: the PCB is located behind the front panel, in the control box.
- To confirm: Saunier Duval Themafast NOx F25 A — with version A; "Themafast Nox F 25"
- To confirm: Saunier Duval Themafast NOx F30 NL/LL — 1 origin with that version: («Nox F 30-NL/LL»)
- To confirm: Saunier Duval Micraplus NOx 24 B2 — with B2; e: "Micraplus Nox 24"
- To confirm: Saunier Duval Thema NOx F25B/2 — 1 origin
- To confirm: Saunier Duval Thema NOx F25 B GN/BP — 1 origin: («THEMANOXF25BGNB»)
- To confirm: Saunier Duval Themafast NOx F30 B/1 — 1 origin
- To confirm: Saunier Duval Thema NOx F30 —: («Thema Nox F30»). and they write «F 30NOx»
- To confirm: Saunier Duval Eura 3 30 SE Low NOx — 1 origin
- To confirm: Saunier Duval Micra 3 24 SE Low NOx — 1 origin
- To confirm: Saunier Duval Micraplus NOx 25:
- Saunier Duval Themaclassic 2: («Tmaclassic 2»)
- Not compatible or excluded: Saunier Duval Thema NOx F24 — it gives another PCB: 288.00.0008.
- Do not confuse: 0010028086 — Vaillant PCB with 0020135165 — Another brand: ours is Saunier Duval PM-02.
- Do not confuse: S1047000 — Themaclassic / Isotwin C24 / Themafast / Isofast circuit — It goes in the parts list of the Themafast F 30 E H-MOD: another family.
- Do not confuse: 288.00.0008 — PCB for Thema NOx F24 and Supermicra Ecoplus — not the one for F25 or F30.
- Both PCBs have V-Group printed on them. They mention 0020141438, 0020124926, and 002014950 along with 0020184123, and 10200, without explaining them: we do not consider them equivalent. Call "Boiler module" to 288.66.0005.
- At least connect 0020183525 or 0020184123 with the Thema/Themafast NOx PCB; 0020106661. Confirmation registered: the F25 B1 and the F30/B-2; the other boilers. Minor discrepancies: 0020135165 (Vaillant PCB) and 288.66.0005 ("Boiler module").
- Pending registered applications to confirm by model, variant, or programming: Saunier Duval Thema NOx F25 B1 (Themanox F25 B1).