
Vaillant PCB 712164 · 735141/02 · For VMI 282-7 R2
Aplicación a la variante exacta pendiente de confirmar. Por confirmar: Es la placa electrónica de la caldera Vaillant, va detrás del frontal. Esa la sospecha cuando la caldera se bloquea del todo, no muestra ninguna luz en el panel o falla al encender de forma aleatoria.
- Type of part
- Vaillant
- Status
- Refurbished
- Catalogue reference
- 712164
- Warranty
- 1 year
Boilers Vaillant compatible with reference 712164
Vaillant con referencia 712164. 0 compatibilidades contrastadas. Hay otros 4 modelos que todavía estamos comprobando.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Vaillant VMI ES 32/362-7 | Vaillant | Unconfirmed |
|---|---|---|
| Vaillant VMI 282-7 R3 | Vaillant | Unconfirmed |
| Vaillant VMI ES 32/362-7 R3 | Vaillant | Unconfirmed |
| Vaillant VMI 282-7 R2 | Vaillant | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if reference 712164 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- To be confirmed: Con la caldera sin tensión, abre el frontal: la PCB va detrás de él.
- Look for 712164 on your PCB and the label 735141/02 on an integrated circuit; also compare 734498, ELMOS 41101C, and 339A 4190A.
- Look at the transformer (EI 30-X6/7048/012) and the circuit markings (TM-AB, TC-AB, TL-AB/77). The chips alone are not enough to identify it.
- No la confundas con la 0020034604, otra placa Vaillant que Sin confirmar: al 712164.
- coinciden, llámanos al 911 17 77 77 con el modelo de tu caldera.
Symptoms that require diagnosis in the Vaillant 712164
Common symptoms and faults
- 01
The boiler completely locks up or does not show any light on the front panel.
Cause: To be confirmed: que vende el 712164 lo cita como señal de placa dañada. Un técnico debe medir antes la alimentación de la placa.
- 02
Random ignition faults.
Cause: La misma los relaciona con la PCB.
- 03
Does not respond to the thermostat, erratic fault codes or relay clicks.
Cause: Se registra como señal de la placa; los códigos de tu caldera están en su manual.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Vaillant 712164
- Catalogue reference
- 712164
- Uniclima internal SKU
- PLC164
- Brand
- Vaillant
- Type of part
- Vaillant
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Barcode on label
- 04 00712164 008 001693 4
- Visible code on bag
- 712164
- Label on an integrated circuit
- 735141/02
- Marked from another integrated circuit
- 734498; ELMOS 41101C; 339A 4190A
- Silkscreens/connectors
- X20, X8, R350, R352-R353, D501, D503
- Marked terminals
- 21 V; 230 V
- Transformer — marked type
- EI 30-X6/7048/012
- Transformer — marked primary
- 230 V; 50-60 Hz; terminals 2-4
- Marked secondary transformer
- 150 V - read; terminals 6-10
- Transformer — additional markings
- 733 674; ta 70/B
- PCB marking
- TM-AB; TC-AB; TL-AB/77
- Datos adicionales — Ubicación
- Detrás del frontal de la caldera
- Identification — Barcode on label
- 04 00712164 008 001693 4
- Identification — Code visible on bag
- 712164
- Identification — Label on an integrated circuit
- 735141/02
- Identification — Marking of another integrated circuit
- 734498; ELMOS 41101C; 339A 4190A
- Identification — PCB Marking
- TM-AB; TC-AB; TL-AB/77
- Technical sheet: Screen prints/connectors
- X20, X8, R350, R352-R353, D501, D503
- Technical sheet: Marked terminals
- 21 V; 230 V
- Transformer — marked type
- EI 30-X6/7048/012
- Transformador — primary marked
- 230 V; 50-60 Hz; terminals 2-4
- Transformer — marked secondary
- 150 V - read; terminals 6-10
- Technical sheet: Transformer — additional markings
- 733 674; ta 70/B
- Pending applications to verify
- VMI 282-7 R2 — compatibilidad citada; pendiente de confirmar por variante.
- To be confirmed: Estos síntomas salen de la ficha, no de una tabla oficial de Vaillant.
- La lista oficial de códigos de Vaillant da la PCB como causa posible de F27, F28, F61 y F62. Es una lista general, no específica de la VMI 282-7 R2 ni de esta placa: Sin confirmar: un código de error concreto a esta placa.
- Por confirmar: Vaillant VMI ES 32/362-7: y (712164)
- Por confirmar: Vaillant VMI 282-7 R3: (712164)
- Por confirmar: Vaillant VMI ES 32/362-7 R3: (712164)
- No confundir: 0020034604 — Placa Vaillant que el despiece del VMI 282-7 R2 llama «Soporte circuito impreso» — Es otro código: sin confirmación adicional abierta lo une al 712164 ni dice que sea equivalente
- No confundir: 735077 V084 — Marcado que junto al 712164 en su módulo VMI ES 32/362-7 — No figura en esta pieza, que lleva 735141/02; no explica la relación
- muestran versiones distintas del 712164 (una «v2», otra con 735077 V084): compara todos los marcados, no solo el 712164.
- dan el 712164 como placa Vaillant; solo la primera nombra la VMI 282-7 R2. Sin despiece oficial. y el despiece de la VMI 282-7 R2 dan 0020034604 para esa caldera; manda lo registrado.
- Aplicaciones registradas pendientes de confirmar por modelo, variante o programación: Vaillant VMI 282-7 R2.
