Vaillant PCB 00712027 · V064D · For VMW 24/282/5 R2
Aplicación a la variante exacta pendiente de confirmar. Por confirmar: Placa de control de la caldera («Circuito Principal de Control» ): recibe las órdenes del termostato y gobierna el funcionamiento. Se sospecha de ella si la caldera no enciende ni responde al termostato, da códigos de error erráticos o se reinicia.
- Type of part
- Vaillant
- Status
- Refurbished
- internal SKU
- PLC186
- Warranty
- 1 year
Compatible Vaillant boilers
Vaillant. 0 compatibilidades contrastadas. Hay otros 9 modelos que todavía estamos comprobando.
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Vaillant VMW 24/282-5 R1 | Vaillant | Unconfirmed |
|---|---|---|
| Vaillant VMW 242/2-5 | Vaillant | Unconfirmed |
| Vaillant VMW 282/2-5 | Vaillant | Unconfirmed |
| Vaillant VMI 282-7 R3 | Vaillant | Unconfirmed |
| Vaillant VMI 280-7 | Vaillant | Unconfirmed |
| Vaillant VMI 320-7 | Vaillant | Unconfirmed |
| Vaillant VMW 282/2-5 R1 | Vaillant | Unconfirmed |
| Vaillant Turbomax Plus 824E / 828E | Vaillant | Unconfirmed |
| Vaillant VMW 24/282/5 R2 | Vaillant | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Locate the PCB behind the front panel, in the control box, and look for the code 00712027 printed on the circuit or on a sticker on the side.
- Also compare the other markings on the PCB: 734766, V064D, TL-AD/66, PM-03 and group 712024/25/28.
- Unconfirmed: 00712027 con 130806 ni con 0020034604. Compara el código de tu placa antes de pedir.
- Check the rating plate to see that the model is VMW 24/282/5 (R2). The spare parts list for the VMW 242/2-5 R4 provides another plate: 0020028413.
- coinciden, llámanos al 911 17 77 77 con el modelo de tu caldera y te la reservamos.
Symptoms that require diagnosis in the Vaillant.
Common symptoms and faults
- 01
The boiler does not ignite or does not respond to the thermostat.
Cause: Lo cita. Comprueba antes que llega tensión correcta a su entrada.
- 02
Erratic fault codes that do not correspond to the actual fault.
Cause: Por confirmar: Lo atribuye a esta PCB.
- 03
Spontaneous resets during normal operation.
Cause: También lo atribuye esa.
- 04
Stuck relays or burnt traces on the PCB.
Cause: Por confirmar: Daño visible; como señal de cambio.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Vaillant
- Uniclima internal SKU
- PLC186
- Brand
- Vaillant
- Type of part
- Vaillant
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Terminal marking
- 21V / 230V
- Inventory — Subcomponent transformer
- 230 V; 50–60 Hz; 3.5 VA
- Inventory — Marked assembly group
- 712024/25/28
- Inventory — Integrated circuit subcomponent
- ELMOS; marked V6C 1180A ELMOS; marked 19C 1148A and 273H98
- Inventory — Application indicated in inventory
- VMW 24/282/5 R2
- Identification — Marked code
- 00712027
- Identification — Marked code
- 734766
- Identification — Marked code
- V064D
- Identification — Marked code
- TM-AD / TC-AD / TL-AD/66 / PM-03
- Marked terminals
- 21V / 230V
- Inventory data — Subcomponent transformer
- 230 V; 50–60 Hz; 3.5 VA
- Inventory data — Marked assembly group
- 712024/25/28
- Inventory data — Integrated circuit subcomponent
- ELMOS; marked V6C 1180A
- Inventory data — Integrated circuit subcomponent
- ELMOS; marked 19C 1148A and 273H98
- Inventory data — Application indicated in inventory
- VMW 24/282/5 R2
- Pending applications to verify
- VMW 24/282/5 R2 — compatibilidad anotada; pendiente de confirmar por variante.
- To be confirmed: Estos síntomas los describe para esta placa; no son una tabla oficial de Vaillant.
- To be confirmed: Con corriente, pantalla apagada y nada que actúe, dice que la placa suele estar averiada.
- Por confirmar: Vaillant VMW 24/282-5 R1 — 1 origen: (00712027),
- Por confirmar: Vaillant VMW 242/2-5: (00712027) y (734766)
- Por confirmar: Vaillant VMW 282/2-5 — 1 origen: (734766)
- Por confirmar: Vaillant VMI 282-7 R3 — 1 origen: (734766)
- Por confirmar: Vaillant VMI 280-7 — 1 origen: (00712027)
- Por confirmar: Vaillant VMI 320-7 — 1 origen: ( de la VMI 280-7)
- Por confirmar: Vaillant VMW 282/2-5 R1 — 1 origen: ( de la VMI 280-7)
- To confirm: Vaillant Turbomax Plus 824E / 828E — 1 source: British portal, only for 734766 (its PCB 130806)
- Not compatible or excluded from origin: Vaillant VMW 242/2-5 R4 — Its spare parts list shows a different PCB: 0020028413
- No confundir: 130806 / 0020034604 — Placas ligadas por: un portal británico da 734766 para su placa 130806 (Turbomax Plus 824E/828E) y 0020034604 con 130805 y 130806 — Ninguna cita 00712027 ni la VMW 24/282/5. Compara todos los marcados antes de pedir.
- No confundir: 0020028413 — Tarjeta de mando de la VMW 242/2-5 R4 en su lista de recambios; italiana la da para varios modelos R4 — Es otra revisión y sin confirmación adicional la une con 00712027.
- To be confirmed: da 00712027 para la VMW 24/282-5 R1; registrada: para la R2. etiqueta su placa de la VMW 24/282-5 con 712024/25/28 y 712026/27/29/30/31, sin citar 00712027.
- To be confirmed: da 00712027 para la VMW 24/282-5 R1; sin lista oficial. Un portal británico da 734766 como PCB de la 130806, y de lo da para VMW 242/2-5 y 282/2-5.
- Aplicaciones registradas pendientes de confirmar por modelo, variante o programación: Vaillant VMW 24/282/5 R2.