Viessmann Vitodens 200 WB2A PCB Ref. 7825241

Viessmann Vitodens 200 WB2A PCB Ref. 7825241

Stock · 1 unit

When you turn on the tap or start the heating, the Viessmann Vitodens 200 WB2A PCB controls the ignition, the modulation of the burner, and the pump of your boiler. If this part fails, the boiler may not start, become locked, or operate erratically, showing faults such as F0, E4, b5, or b4. This board is compatible with models from the Vitodens 200-W and Vitodens 300-W ranges, among others. It should be replaced when you experience these operational issues.

VAT included

Compatibility

Viessmann boilers compatible with reference 7825241

PCB with reference 7825241. Six confirmed compatibilities: Vitodens 200-W WB2A 26 kW and Vitodens 300-W WB3A 26 kW.

Proven compatibility

Boiler modelFamilyVerification
Viessmann Vitodens 200-W WB2A 26 kWVitodens 200-W (WB2A)Contrasted
Viessmann Vitodens 300-W WB3A 26 kWVitodens 300-W (WB3A)Contrasted
Viessmann Vitodens 300-W WB3A 35 kWVitodens 300-W (WB3A)Contrasted
Viessmann Vitodens 300-W WB3A 49 kWVitodens 300-W (WB3A)Contrasted
Viessmann Vitodens 300-W WB3A 66 kWVitodens 300-W (WB3A)Contrasted
Viessmann Vitodens 300-W WB3B 35 kWVitodens 300-W (WB3B)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 7825241 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 7825241. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 7825241 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not turn on: there is no light on the display and nothing can be heard, it seems unplugged.

    Cause: The PCB distributes power to the electronics, and if its input fails, no current reaches anything.

    Before replacing it, check the fuse on the PCB and make sure there is voltage at the input connector.

  • 02

    The display shows different fault codes or the same warning appears and disappears.

    Cause: The PCB interprets the signals from the sensors, and if it fails, it generates errors that are not real.

    Note the exact codes and the order in which they appear: a dirty sensor or a loose connector can give the same symptom without it being the PCB.

  • 03

    You change the temperature on the control and the boiler does not respond, it keeps operating as it wants.

    Cause: The remote control communicates with the boiler through the PCB, and if the bus port fails, control is lost.

    Try to operate the boiler using its own buttons before ruling out the PCB: if it still doesn't respond, the fault may be the PCB.

  • 04

    The boiler starts, runs for a while, and then shuts down on its own for no apparent reason, then tries again.

    Cause: A relay on the PCB that fails can intermittently cut off the power to the ignition.

    First, rule out a drop in water pressure or a fault in the air pressure switch, which can cause the same shutdown without it being the PCB.

Fault codes Viessmann that this part solves

CodeFaultDiagnosis and solution
F0Internal fault; burner locked.Internal fault of the boiler control unit (PCB). Check 230/24 V, wiring, and sensors; if everything is correct and the code persists, the PCB is faulty and must be replaced.
E4Burner blocked; fault in the 24 V power supply.Fault in the 24 V supply/monitoring circuit on the control board. Measure the 24 VDC output and peripherals; if the voltage is correct and the alarm persists, the PCB is defective and must be replaced.
b5Control mode according to delivery; internal fault.Internal fault in the regulation electronics (PCB). Confirm that there are no programming/Vitotrol errors and reset; if it reappears, replace the control board.
b4Regulates as if the outside temperature were 0 °C; internal fault.A/D converter fault or measurement on the control board causing incorrect external reading. Check the external sensor and resistances at terminals; if they are correct and the fault code persists, the PCB is damaged and must be replaced.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Viessmann 7825241 PCB.

Catalogue reference
7825241
Brand
Viessmann
Type of part
PCBs (control boards)
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Frequently Asked Questions

Frequently asked questions about the PCB 7825241

Is this PCB suitable for the Viessmann Vitodens 300 WB3A, or only for the 200 WB2A?
It is suitable for both: it is indicated as compatible with Vitodens 200 WB2A, 300 WB3A, 300 WB3B, and 333 WS3A.
Is this PCB suitable for the Vitodens 333 WS3A?
Yes, it is on the list of compatible boilers along with the Vitodens 200 WB2A, 300 WB3A, and 300 WB3B.