Saunier Duval Pressure Sensor Ref. 0020016532

Saunier Duval Pressure Sensor Ref. 0020016532

Measure the pressure of the water circuit and send the information to the control board. If the pressure sensor of your Saunier Duval boiler fails, you may notice incorrect readings and lockouts due to a false lack of pressure, which may trigger the fault code F9. This sensor is compatible with several models from the ThemaClassic range, such as the F 25 E, C 25 E, F 30 E, C 24 E1, and F 24 E1, as well as the F 35 E model from the Isofast range. A technician must confirm through diagnosis whether it needs to be replaced when you experience pressure issues or lockouts in the operation of the boiler.

Type of part
Pressure sensors
Catalogue reference
S5720500
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Saunier Duval boilers compatible with reference S5720500

Pressure sensor with reference S5720500. Six confirmed compatibilities: F 25 E and C 25 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval F 30 EThemaClassicContrasted
Saunier Duval C 24 E1ThemaClassicContrasted
Saunier Duval F 24 E1ThemaClassicContrasted
Saunier Duval F 35 EIsofastContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720500 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720500. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the pressure switch S5720500

The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start and the display shows that there is a lack of pressure, even though the circuit is full.

    Cause: The sensor sends a false low pressure reading and the PCB cuts off the ignition for safety.

    Measure the pressure with a needle manometer; if it does not match the digital reading, the problem is the sensor.

  • 02

    The pressure displayed on the boiler fluctuates on its own without touching the filling tap.

    Cause: A sensor with a damaged membrane or internal circuit generates an unstable signal to the PCB.

    Observe the value on the screen for a few minutes with the boiler off; if it fluctuates without reason, it is not a filling issue.

  • 03

    The boiler intermittently locks out: sometimes it starts and sometimes it doesn't.

    Cause: A sensor with an internal contact fault gives inconsistent signals depending on the moment.

    Try to start the boiler several times in a row and note whether the fault is constant or intermittent; this helps to distinguish the fault of the sensor from an installation problem.

  • 04

    The pressure fault warning persists even after bleeding the air and refilling the circuit.

    Cause: If the PCB does not receive a coherent signal from the sensor, it will continue to block even if the actual pressure is correct.

    Check the condition of the electrical connector of the sensor (oxidation, moisture, bent pins) before considering it faulty.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F9Water pressure sensor fault.The pressure transducer S5720500 delivers an absent/out-of-range signal or does not reach the PCB, the electronics interpret an abnormal pressure and lock with F9; verify by measuring the sensor signal and the harness/wiring and comparing with an external manometer.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for Saunier Duval pressure sensor S5720500

Catalogue reference
S5720500
Uniclima internal SKU
CPCICF30E1
Brand
Saunier Duval
Type of part
Pressure sensors
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Part code (label)
0020016532
Batch brand
lot: 150920 A
Frequently Asked Questions

Frequently asked questions about the pressure sensor S5720500

Is this pressure sensor Saunier Duval Ref. 0020016532 compatible with my boiler?
Yes, this pressure switch is compatible with the models from the 'ThemaClassic' range F 25 E, C 25 E, F 30 E, C 24 E1, F 24 E1 and 'Isofast' F 35 E.
What fault can be resolved by replacing the pressure switch?
It should be checked when the boiler shows incorrect pressure readings or gets blocked for this reason, as the sensor measures the pressure of the water circuit. Replacement requires a technical diagnosis.
How many models are compatible with this pressure switch?
This pressure switch is compatible with a total of 6 boiler models.
What fault code is associated with this pressure sensor?
The documented fault code for this product is F9.
What is the reference for this pressure sensor?
CPCICF30E1 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.

Spare parts related to Saunier Duval ThemaClassic

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Saunier Duval Pressure Sensor Ref. 0020016532