Pressure Sensor Saunier Duval ThemaClassic F 25 E Ref. S5720500

Pressure Sensor Saunier Duval ThemaClassic F 25 E Ref. S5720500

Stock · 5 units

When you open the tap or turn on the heating, the pressure sensor Saunier Duval ThemaClassic F 25 E measures the water pressure in the circuit and sends the information to the control board. If this part fails, you may notice incorrect readings and, in some cases, lockouts due to a false lack of pressure, which could manifest with the fault code F9. This sensor is compatible with several boilers in the ThemaClassic range, such as the F 25 E, C 25 E, and F 30 E, among others. It is recommended to replace it when you start experiencing these operational issues.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720500

Pressure sensor with reference S5720500. Six confirmed compatibilities: F 25 E and C 25 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval F 30 EThemaClassicContrasted
Saunier Duval C 24 E1ThemaClassicContrasted
Saunier Duval F 24 E1ThemaClassicContrasted
Saunier Duval F 35 EIsofastContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720500 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720500. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure sensor S5720500 resolves.

The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler intermittently locks out with a pressure fault warning, sometimes yes and sometimes no, without a clear pattern.

    Cause: The sensor gives unstable readings and the control unit shuts down operation when the signal goes out of the expected range.

    Note whether the fault occurs always when starting cold or also when hot; this helps to distinguish the sensor from another cause.

  • 02

    The pressure displayed on the screen does not match the reading on the boiler's analog manometer.

    Cause: The sensor element loses calibration and incorrectly translates the actual hydraulic pressure into an electrical signal.

    Take note of the difference between both readings over several days before deciding on the change.

  • 03

    When filling with water and increasing the pressure, the boiler takes time to reflect it on the screen or the change is barely noticeable.

    Cause: The sensor responds slowly or weakly to changes in the circuit pressure.

    Check the connector and the cable of the sensor; a poor connection can also delay or distort the reading.

  • 04

    Moisture or small droplets are observed around the thread where the sensor is installed.

    Cause: Over time, the part loses its tightness and allows water from the circuit to escape from that point.

    Dry the area well and check after a few minutes of operation if the humidity reappears right there.

Fault codes from Saunier Duval that this spare part resolves.

CodeFaultDiagnosis and solution
F9Water pressure sensor fault.The pressure transducer S5720500 delivers an absent/out-of-range signal or does not reach the PCB, the electronics interpret an abnormal pressure and lock with F9; verify by measuring the sensor signal and the harness/wiring and comparing with an external manometer.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for Saunier Duval pressure sensor S5720500

Catalogue reference
S5720500
Brand
Saunier Duval
Type of part
Pressure sensors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Printed code
PSN0001 A
Batch code/date
46/00
Place of manufacture
Made in France
Marked
CE
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure sensor S5720500

Does this pressure switch work for the Saunier Duval Isofast F 35 E?
Yes, it is on the list of compatible boilers, along with Isomax F 28 E and the Thema, ThemaClassic, and ThemaPlus F 25 E ranges indicated.
Is it also suitable for the Saunier Duval Thema C 24 E?
Yes, Thema C 24 E is among the compatible models for this part.
Where is this part of the Saunier Duval ThemaClassic manufactured?
In France, according to the 'Made in France' label and the CE marking on the label.
What fault requires changing this sensor in a Saunier Duval Thema F 25 E?
It is replaced when the boiler detects a pressure reading fault associated with this component.
How can I distinguish this part from the sensor of the Renova Teknic F 23 E, which shares the same reference S5720500?
According to the recorded code: this one has PSN0001 A, while the Renova Teknic one has PSN0001 B.

Spare parts related to Saunier Duval ThemaClassic

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model