Pressure Sensor Saunier Duval Isofast F 30 E H MOD - Code 0020016532

Pressure Sensor Saunier Duval Isofast F 30 E H MOD - Code 0020016532

When you open the tap or start the heating, the pressure sensor Saunier Duval Isofast F 30 E H MOD - Code 0020016532 is responsible for measuring the water circuit pressure and sending the information to the control board. If this sensor fails, you may notice incorrect readings and lockouts due to a false lack of pressure, which can lead to malfunctioning of the boiler. It is compatible with models such as F 25 E, C 25 E, F 30 E, C 24 E1, F 24 E1, and F 35 E, among others. A technician must confirm through diagnosis whether it needs to be replaced when these symptoms occur or a fault of the water pressure detector (F9) is detected.

Type of part
Pressure sensors
Catalogue reference
S5720500
Warranty
1 year
VAT included Stock · 6 units
Compatibility

Saunier Duval boilers compatible with reference S5720500

Pressure sensor with reference S5720500. Six confirmed compatibilities: F 25 E and C 25 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval F 25 EThemaClassicContrasted
Saunier Duval C 25 EThemaClassicContrasted
Saunier Duval F 30 EThemaClassicContrasted
Saunier Duval C 24 E1ThemaClassicContrasted
Saunier Duval F 24 E1ThemaClassicContrasted
Saunier Duval F 35 EIsofastContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720500 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720500. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the pressure switch S5720500

The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler shows a pressure warning when trying to ignite, even though the circuit is properly charged.

    Cause: The sensor sends a reading outside the safe range to start.

    Check with the boiler's pressure gauge that the pressure is between 1 and 1.5 bar when cold before replacing the part.

  • 02

    The boiler works for a while and then stops by itself showing a pressure fault.

    Cause: A fluctuating signal from the sensor causes the control unit to interpret a pressure drop that does not exist.

    Check the wiring and the connector of the sensor for any intermittent loose contact.

  • 03

    You have re-pressurized the circuit and the boiler displays the same warning upon starting.

    Cause: The sensor keeps sending the same incorrect data, no matter what you do with the filling valve.

    Compare the reading on the display with the mechanical manometer after properly bleeding the circuit.

  • 04

    The pressure fault code always appears at the same point in the ignition cycle.

    Cause: The PCB requires a valid pressure reading at that specific step to continue the startup.

    Note the exact moment the fault appears to rule out an air bleeding issue.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
F9Water pressure sensor fault.The pressure transducer S5720500 delivers an absent/out-of-range signal or does not reach the PCB, the electronics interpret an abnormal pressure and lock with F9; verify by measuring the sensor signal and the harness/wiring and comparing with an external manometer.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for Saunier Duval pressure sensor S5720500

Catalogue reference
S5720500
Uniclima internal SKU
CPIF30EHMOD
Brand
Saunier Duval
Type of part
Pressure sensors
Units in stock
6 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Code printed on the part
0020016532
Batch production
120104 B
Frequently Asked Questions

Frequently asked questions about the pressure sensor S5720500

What is the code and batch number for the pressure sensor of the Saunier Duval Isofast F 30 E H MOD?
The code 0020016532, with batch 120104 B, read in this same unit.
For which models is this pressure sensor compatible?
It is compatible with the models from the 'ThemaClassic' range: F 25 E, C 25 E, F 30 E, C 24 E1, F 24 E1 and with the model from the 'Isofast' range: F 35 E.
What fault indicates that this pressure switch needs to be replaced?
That the boiler shows a pressure fault or does not start due to a pressure reading failure.
What is the reference for this pressure sensor?
CPIF30EHMOD is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
What fault code is documented for this pressure sensor?
The documented fault code is F9.
How many models are compatible with this pressure switch?
There are a total of 6 models confirmed as compatible.

Spare parts related to Saunier Duval ThemaClassic

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Pressure Sensor Saunier Duval Isofast F 30 E H MOD - Code 0020016532