Water Pressure Sensor Saunier Duval Isomax F 28 E Ref. S5720500
Water pressure sensor for Saunier Duval boilers. The label only contains the internal code PSN0001 A, marked CE and 'Made in France'; there is no manufacturer's name printed. It is compatible with a wide range of Saunier Duval (Isomax, Thema, Ultimate, Isofast, among others). It is replaced if the boiler does not read the water circuit pressure correctly.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S5720500
Pressure sensor with reference S5720500. Six confirmed compatibilities: F 25 E and C 25 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval F 25 E | ThemaClassic | Contrasted |
| Saunier Duval C 25 E | ThemaClassic | Contrasted |
| Saunier Duval F 30 E | ThemaClassic | Contrasted |
| Saunier Duval C 24 E1 | ThemaClassic | Contrasted |
| Saunier Duval F 24 E1 | ThemaClassic | Contrasted |
| Saunier Duval F 35 E | Isofast | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5720500 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5720500. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure sensor S5720500 resolves.
The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler shows a water pressure fault even though the circuit has the correct pressure.
Cause: The sensor sends an incorrect reading of the actual pressure in the circuit.
Measure the pressure with the boiler's manometer or an external one before changing the sensor.
- 02
The pressure indicator is unresponsive, it remains stuck or shows zero.
Cause: The sensor has stopped generating the signal corresponding to the water pressure.
Bleed or fill the circuit and observe if the indicator reacts; if it does not change, the signal is not reaching the PCB.
- 03
The pressure reading on the display shows values that change for no apparent reason.
Cause: A fault in the sensor or its connection causes an unstable signal that the PCB interprets as pressure variations.
Check the connector of the sensor for any rust or poor contact before replacing the part.
- 04
The boiler locks out when trying to ignite, without allowing any more time.
Cause: Without a valid pressure signal, the control board does not allow ignition for safety reasons.
Check that there is water in the circuit and that the filling valves are open before suspecting the sensor.
Fault codes from Saunier Duval that this spare part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| F9 | Water pressure sensor fault. | The pressure transducer S5720500 delivers an absent/out-of-range signal or does not reach the PCB, the electronics interpret an abnormal pressure and lock with F9; verify by measuring the sensor signal and the harness/wiring and comparing with an external manometer. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for Saunier Duval pressure sensor S5720500
- Catalogue reference
- S5720500
- Brand
- Saunier Duval
- Type of part
- Pressure sensors
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Printed code
- PSN0001 A
- Marked
- CE
- Place of manufacture
- Made in France
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval F 25 E Manual (PDF)Document © Saunier Duval, provided as a technical reference.