Flow meter Saunier Duval Isofast C-F 24-35E - Ref. S5720200

Flow meter Saunier Duval Isofast C-F 24-35E - Ref. S5720200

Stock · 5 units

When you open the tap of your Saunier Duval Isofast C-F 24-35E boiler, the flow meter detects the passage of water and activates the ignition to heat the domestic hot water. If this part fails, you will notice that no hot water comes out even when the tap is open. This flow meter is compatible with several models, including those from the ThemaClassic, Themafast, Thematek, Isofast, Isomax, Isotwin, and Opalia ranges, among others. It is recommended to replace it when you experience a lack of hot water at the tap.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    No hot water comes out when the tap is opened, no matter how long you wait.

    Cause: The flow meter does not close the flow detection contact, and the boiler never receives the command to start the burner.

    Check that there is normal pressure and flow in the cold water before touching the flow meter: without incoming flow, it won't detect anything either.

  • 02

    The burner does not ignite when requesting hot water, although the boiler works fine for heating.

    Cause: The flow meter only intervenes in the production of hot water, so the fault is limited to that circuit.

    Check that the fault occurs at all the taps in the house before considering the part as faulty.

  • 03

    The hot water comes out in bursts, rising and falling in temperature without touching the tap.

    Cause: An intermittent flow detection causes the boiler to turn the burner on and off in short modulations.

    Bleed the air from the domestic hot water circuit and check the inlet filter before replacing the part.

  • 04

    The domestic hot water has suddenly stopped working, without any prior warning or visible error.

    Cause: If the flow meter gets stuck without ever closing the contact, the boiler simply does not see the demand for hot water.

    Measure the continuity of the wiring of the flow meter with a multimeter before replacing it, in case the fault is due to a connection issue and not the part itself.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow Detectors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Silkscreened code line 1
000010351900000
Screen-printed code line 2 (unit variable)
0290502001010
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is this flow meter suitable for a Saunier Duval Isofast C 24 E?
Yes, the Isofast C 24 E is on the list of compatible boilers for this part.
What codes are engraved on this flow meter?
On the plate, two lines appear: 000010351900000 and 0290502001010.
Is this flow meter also suitable for a Saunier Duval Themacondens F 30?
Yes, the Themacondens F 30 is on the list of compatible boilers along with Isofast, Isomax, Isotwin, Opalia, Semia, Thema, and Themaclassic.
When should the flow meter of the Isofast C 24 E be replaced?
When the start of domestic hot water (DHW) fails, since this part detects the flow of water to activate it.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model