Domestic Hot Water Flow Sensor Saunier Duval Isomax F 28 E2

Domestic Hot Water Flow Sensor Saunier Duval Isomax F 28 E2

Stock · 5 units

Detects the flow of water when a tap is opened and commands the ignition to produce domestic hot water (DHW). If it fails, you will notice that hot water does not come out even though the tap is open. This flow sensor is compatible with various Saunier Duval boilers, including models such as Isomax C28E, Isomax F28E, and others from the Isomax range, among others. Replacement is recommended when these symptoms occur to restore DHW production.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    When opening the hot water tap, the boiler does not start: it does not attempt to ignite the burner.

    Cause: The NTC thermistor does not detect the flow of water, so the PCB never receives the demand signal for domestic hot water.

    Open the tap fully and check that water is actually flowing before declaring the sensor faulty.

  • 02

    Hot water comes out for a while and then suddenly cools down, even though the tap remains open.

    Cause: The accumulated scale on the thermistor distorts its reading, and the control unit interprets that water has stopped flowing.

    If the area has hard water, check for visible limescale on the 28 mm thread before replacing the sensor.

  • 03

    The heating works well, but the hot water from the tap never starts.

    Cause: This part only operates in the domestic hot water circuit, so a fault here does not affect heating and vice versa.

    Check that the fault occurs in all the taps in the house and not just in one, to rule out an installation issue.

  • 04

    The flow of hot water seems weaker than normal even though the pressure of the boiler is fine.

    Cause: An intermediate reading of the thermistor due to dirt can cause the control board to limit the ignition instead of allowing it to fully ignite.

    Measure the actual flow rate with a bucket and a stopwatch at the tap to rule out that the problem is in the installation.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Type of component and connections
Domestic hot water flow sensor, thermistor type (NTC), male thread 18 mm + female 28 mm
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is the ACS flow sensor Saunier Duval CIF28E2 compatible with my Isomax F 28 E2 boiler?
Yes, the ACS flow sensor Saunier Duval CIF28E2 is compatible with the Isomax F 28 E2 boiler.
What is the function of the flow sensor in the Isomax F 28 E2 boiler?
Detects the flow of water and activates the ignition of the boiler to produce domestic hot water (DHW).
Does this flow sensor also work for the ThemaClassic range boilers?
Yes, the ACS flow sensor Saunier Duval CIF28E2 is compatible with several models from the ThemaClassic range.
How many boiler models are compatible with the ACS flow sensor Saunier Duval CIF28E2?
The sensor is compatible with a total of 33 boiler models.
Are there documented fault codes for the ACS flow sensor Saunier Duval CIF28E2?
No, there are no documented fault codes for this product.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Domestic Hot Water Flow Sensor Saunier Duval Isomax F 28 E2