Domestic Hot Water Flow Sensor Saunier Duval Isomax F 28 E

Domestic Hot Water Flow Sensor Saunier Duval Isomax F 28 E

Stock · 5 units

The ACS Flow Sensor Saunier Duval Isomax F 28 E is a device that detects the flow of water when a tap is opened, thereby activating the ignition for the production of domestic hot water. When this part fails, you will notice that hot water does not come out even when the tap is open. It is compatible with several boilers from the Isomax range, as well as from the ThemaClassic, Themafast, Thematek, Isofast, Isotwin, and Opalia ranges, among others. It should be replaced when there are issues with the supply of hot water.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite the burner when the hot water tap is opened, in any part of the house.

    Cause: The flow sensor is not sending the water flow signal to the boiler.

    Check for a general cold water cut-off before replacing the sensor: without cold water input, the domestic hot water system won't start either.

  • 02

    The hot water comes out in bursts, stops, and then comes out again for no apparent reason.

    Cause: The sensor gives unstable readings due to deposits, and the boiler turns the burner on and off following that erratic signal.

    Bleed the domestic hot water circuit properly before concluding that the sensor is faulty: air in the pipe produces the same effect.

  • 03

    The boiler only fails with the domestic hot water; the heating works perfectly.

    Cause: The flow sensor only operates in the DHW circuit, so a fault here does not affect the heating.

    Confirm that the fault occurs in all taps and not just in the one farthest from the boiler.

  • 04

    The flow of hot water has decreased even though the overall pressure of the system is correct.

    Cause: Lime deposits on the sensor can give a partial reading that prevents the boiler from modulating at maximum power.

    Check the cold water inlet filter before the sensor: if it is dirty, it produces the same symptom without the part being faulty.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Type of component and connections
Domestic hot water flow sensor, thermistor type (NTC), male thread 18 mm + female 28 mm
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Does this domestic hot water flow sensor work for my Saunier Duval Isomax F 28 E?
Yes, it is on the list of compatible boilers for this part.
Is this flow sensor compatible with a Saunier Duval Opalia F 14 E?
Yes, the Opalia F 14 E is on the list of compatible boilers along with several models of Isomax, Isofast, Isotwin, and Themaclassic.
What happens if the flow sensor of the Isomax F 28 E fails?
The boiler's ignition does not activate when the domestic hot water tap is opened because it does not detect the flow of water.