Flow meter Saunier Duval Isofast Condens F 35 E Ref. S5720200

Flow meter Saunier Duval Isofast Condens F 35 E Ref. S5720200

VAT includedStock · 7 units

When you open the hot water tap, the Saunier Duval Isofast Condens F 35 E flow meter (Ref. S5720200) activates to detect the water flow and allow the boiler to ignite. This part is responsible for ensuring that hot water flows to the tap. If it fails, you will notice that no hot water comes out, even though the tap is open. It is installed in boilers from the Isofast range, among others, such as Isofast C28E, Isofast C35E, and Isofast Condens F30E. It is advisable to replace it if you experience these hot water supply issues.

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler heats the radiators well, but the domestic hot water does not reach or is lukewarm.

    Cause: The sensor does not send the flow signal to the control board, and it does not command the ignition in DHW mode.

    Check that the cold water inlet filter is not clogged with limescale; insufficient flow due to this reason can mimic the fault of the sensor.

  • 02

    The hot water appears and disappears while the tap remains open, without anyone turning it off.

    Cause: An unstable reading from the flow meter causes the boiler to repeatedly turn the burner on and off.

    Open the tap to the maximum: if the cut only occurs at low flow, it may be a network pressure issue, not a sensor problem.

  • 03

    The display shows a fault warning for the flow meter or flow sensor.

    Cause: The electronics detect a signal outside the expected values and block the domestic hot water system to protect the boiler.

    Reset the boiler and try again: if the warning reappears when opening the tap, check the sensor in more detail before ordering it.

  • 04

    The domestic hot water fault appears equally in different taps throughout the house.

    Cause: If the fault is general and not specific to a faucet, it indicates that the problem lies in the flow meter and not in the faucet or the installation.

    Discard a faulty thermostatic or mixing tap by testing with a conventional tap.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Code engraved on the part
0001035190000
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is the flow meter Saunier Duval Isofast Condens F 35 E Ref. S5720200 compatible with the boiler Isofast Condens F 35 E?
Yes, the flow meter is compatible with the Isofast Condens F 35 E, which is part of the list of compatible boilers.
What boiler models are compatible with the Saunier Duval Isofast Condens F 35 E flow meter?
The flow meter is compatible with a total of 33 models, including the ThemaClassic, Themafast, Thematek, Isofast, Isomax, Isotwin, Opalia, Thema Nox / Thema Condens, and Semia ranges.
When should I replace the flow meter of my boiler?
You must replace the flow meter when the boiler does not detect water flow and does not produce domestic hot water (DHW), or if it shows a fault of the flow sensor.
Does the Saunier Duval Isofast Condens F 35 E flow meter work for the Isofast F 28 E?
Yes, the flow meter is compatible with the Isofast F 28 E, as well as with other models in the Isofast range.
What is the reference for the Saunier Duval Isofast Condens F 35 E flow meter?
CSDICF35E is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
Are there documented fault codes for the Saunier Duval Isofast Condens F 35 E flow meter?
No, there are no documented fault codes for this product.