Saunier Duval Themafast F 25 E Flow Meter - Cod. 00001035190000

Saunier Duval Themafast F 25 E Flow Meter - Cod. 00001035190000

Stock · 5 units

In Saunier Duval Themafast boilers, the flow meter 00001035190000 (S5720200) acts as a flow detector that recognizes the passage of water when a tap is opened, thus activating the ignition for the production of domestic hot water (DHW). If this part fails, you will notice that hot water does not come out even when the tap is open. This flow meter is compatible with models such as Themafast C24E, C25E, among others. It is advisable to replace it if you experience a lack of hot water when opening the tap.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The hot water tap delivers cold or lukewarm water even though the boiler has pressure and gas.

    Cause: The flow meter does not send the demand signal for hot water to the control board, even though the water is circulating through the pipe.

    Check that the cold water shut-off valve is fully open and that there is no improperly adjusted thermostatic mixer before checking the flow meter.

  • 02

    The boiler only ignites the domestic hot water burner if the tap is fully opened.

    Cause: The turbine of the flow meter requires more flow than usual to rotate because it is partially obstructed by scale or particles.

    Remove the inlet filter, if present, and check for scale or accumulated debris before considering replacement.

  • 03

    The flow of hot water fluctuates even when the tap is held steady.

    Cause: The water flow through the flow meter is not uniform, usually due to dirt in the turbine, and the control board modulates the flame based on that irregular signal.

    Check if the problem occurs in all the taps in the house or just in one; if it is only in one, the source is not in the flow meter.

  • 04

    The boiler does not detect the demand when there is low flow, for example, with the tap slightly open.

    Cause: It is typical of this type of sensors: if the flow drops below the minimum detection level, they do not send a signal even if there is a real flow.

    Open the tap a little more to check if the boiler ignites at a certain flow rate; that indicates a sensitivity issue, not a total fault.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Silkscreened code (line 1)
00001035190000
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is this flow meter compatible with the Saunier Duval Themafast F25E?
Yes, the Themafast F25E is on the list of compatible boilers in this document.
Does this flow meter also work for the Isomax F35E?
Yes, the Isomax F35E appears in the list of compatible models for this part.
What typical fault leads to checking the flow meter of the Themafast F25E?
That the boiler does not provide domestic hot water despite having the correct pressure, as this component detects the water flow to activate the DHW mode.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model