Saunier Duval Isofast C 35 EA flow meter Ref. S5720200

Saunier Duval Isofast C 35 EA flow meter Ref. S5720200

Stock · 7 units

Isofast is the range of boilers where the flow meter Saunier Duval Isofast C 35 EA Ref. S5720200 is installed. This flow detector has the function of detecting the flow of water when a tap is opened, thus activating the ignition to produce domestic hot water. When it fails, the user will notice that hot water does not come out despite having the tap open. It is used in models such as Isofast C28E, Isofast F28E, and others in the same range. It is recommended to replace it when these symptoms occur.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler heats well for heating, but the hot water takes a long time to arrive or does not come out hot.

    Cause: The flow meter does not detect the passage of water, so the boiler does not switch to domestic hot water mode even though the burner is available.

    Open the tap to maximum flow for a few seconds and see if the boiler reacts; a very low flow for another reason can also prevent the start-up.

  • 02

    The hot water comes out in intervals, heating up and cooling down for no apparent reason while the tap is open.

    Cause: The internal contact of the sensor is intermittently lost, and the control board interprets demand cuts that do not exist.

    Check the flow meter connector: if it is loose or corroded, it may give erratic readings before replacing the part.

  • 03

    The display shows a warning or fault code related to the flow rate or the domestic hot water sensor.

    Cause: The control unit has detected an out-of-range signal from the flow meter and blocks the production of hot water for safety reasons.

    Note the exact code and consult the boiler manual: some flow warnings refer to the general water pressure, not to the sensor.

  • 04

    The heating works well, but the hot water does not start in any faucet in the house.

    Cause: If the fault affects all consumption points, the problem lies with the flow meter and not with the plumbing installation.

    Check at more than one tap before deciding: if only one is failing, the problem is not the flow meter.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Code engraved on the part
0001035190000
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is this flow meter suitable for the Themafast C 24 E?
Yes, it is on the list of compatible boilers for this part.
Is this flow meter suitable for the Semia F 25?
Yes, it is on the list of compatible boilers for this part.
When should the flow meter of the Isofast C 35 EA be replaced?
When the boiler does not detect water flow and does not produce domestic hot water, or shows a fault with the flow sensor.
Is it the same part as the flow meter of the Isofast C 35 E1?
Both share the same commercial reference S5720200, although each corresponds to a different model of Isofast boiler.

Spare parts related to Saunier Duval Themafast

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Isofast C 35 EA flow meter Ref. S5720200