Saunier Duval Flowmeter Flow Detector ThemaClassic F 24 E Ref. S5720200

Saunier Duval Flowmeter Flow Detector ThemaClassic F 24 E Ref. S5720200

Stock · 6 units

The Saunier Duval flow meter Detector Flujo ThemaClassic F 24 E is a device that detects the flow of water when a tap is opened, allowing the boiler to ignite for the production of domestic hot water (DHW). When this part fails, you will notice that hot water does not come out even with the tap open. It is installed in several boiler models, including ThemaClassic C24E, ThemaClassic C25E, and Thema Nox F25, among others. Replacing this part is necessary when you experience issues obtaining hot water.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    You turn on the tap and the boiler doesn't react at all, it continues as if no one is asking for water.

    Cause: The flow detector is not sending the signal to the control board, so the domestic hot water system does not start.

    Check that the flow at the tap is normal and that there is no aerator or filter blocked before replacing it.

  • 02

    The hot water fluctuates in temperature on its own, without touching anything.

    Cause: A detector with a dirty or worn paddle gives irregular flow readings.

    Check if the fault always occurs after a water cut or only with prolonged use of the tap.

  • 03

    With the tap almost closed it doesn't heat, but fully open it does.

    Cause: A minimum flow rate is required for the detector to close the contact and request ignition.

    Try opening the tap to the maximum; if it turns on, check the mains pressure before the detector.

  • 04

    Do you notice a faint noise or rattling in the hot water pipe when you turn on the faucet?

    Cause: A loose or worn internal moving part can vibrate as water flows through.

    Check if the noise disappears by lowering the inlet pressure before attributing it to the sensor.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
6 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

For which models is the Saunier Duval flow meter Detector Flujo ThemaClassic F 24 E Ref. S5720200 compatible?
It is compatible with 33 models from the ThemaClassic, Themafast, Thematek, Isofast, Isomax, Isotwin, Opalia, Thema Nox, Thema Condens, and Semia ranges.
What is the reference for the flow meter?
The reference of the flow meter is DFTF24E.
What number is marked on the part?
Only a number in relief specific to the plastic mold, without any technical data or readable manufacturer reference.
Is this flow meter suitable for Themafast boilers?
Yes, it is compatible with the Themafast C24E, Themafast C25E, Themafast C28E, Themafast Condens F24E, and Themafast Condens F25 models.
What fault codes does this product have?
There are no documented fault codes.
Can I use this flow meter in a boiler from the Opalia range?
Yes, it is compatible with the Opalia C16E, Opalia F11E, Opalia F14E, and Opalia F17E models.

Spare parts related to Saunier Duval Themafast

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Flowmeter Flow Detector ThemaClassic F 24 E Ref. S5720200