Flow detector for the domestic hot water circuit. According to two external sources, reference S5720200 corresponds to a Saunier Duval flow sensor/DHW, although it is not printed on this unit. The part is marked with the embossed numbers 000010135190000 / 21009202501010 and the code 300 on the green board of the sensor. It is replaced when flow detection fails.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    There is no hot water when turning on the tap, although the heating is working fine.

    Cause: The flow detector activates the hot water mode independently of the heating circuit, so its fault only affects the hot water from the tap.

    Check if the problem occurs in all the taps in the house and not just one, to rule out that it is an issue with the installation and not with the boiler.

  • 02

    The burner does not start when you request hot water; it remains on standby.

    Cause: Without the flow signal, the control board understands that there is no real consumption and does not allow ignition in that mode.

    Before changing the part, open the tap to the maximum for a few seconds: if it ignites with high flow, the sensor may be dirty instead of broken.

  • 03

    The water comes out lukewarm or with temperature fluctuations, it does not stabilize at hot.

    Cause: An unstable flow reading due to dirt or wear causes the PCB to modulate the burner erratically following that signal.

    Check the cold water inlet filter of the boiler: if it accumulates limescale, it reduces the actual flow reaching the sensor and causes this effect.

  • 04

    The fault started right after construction work or a water outage in the area.

    Cause: A supply cut often carries sand or lime into the system, and that first settles in the flow detector as it is a narrow piece with moving parts.

    If the fault coincides with construction work, a water cut, or pipe cleaning, disassemble the detector and check for any visible debris before declaring it faulty.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow Detectors
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Embossed marking of the plastic plug
000010135190000 / 21009202501010
Code on the sensor PCB (green PCB)
300
Reference S5720200 (Saunier Duval flow sensor/DHW)
S5720200 is a genuine Saunier Duval reference for a flow/domestic hot water sensor, according to 2 external sources; it does not appear printed on this unit.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is this flow detector Ref. S5720200 suitable for boilers from the Saunier Duval Isotwin series?
Yes, the Isotwin series is on the list of compatible boilers for this part.
When should this flow detector be replaced in a Saunier Duval boiler from the Thema series?
When the flow detection in the domestic hot water circuit fails.
Is this sensor also suitable for the Saunier Duval Opalia series?
Yes, the Opalia series is on the list of compatible boilers for this part.