Flow meter Saunier Duval Isofast F28E Ref. S5720200

Flow meter Saunier Duval Isofast F28E Ref. S5720200

Stock · 5 units

The Saunier Duval Isofast F28E flow meter, Ref. S5720200, is a flow detector that senses the flow of water when a tap is opened and activates the ignition to produce domestic hot water. When it fails, the user will notice that no hot water comes out, even though the tap is open. This flow meter is compatible with several models, such as Isofast C28E, Isofast C35E, and others from the Isofast range, among others. It should be replaced when symptoms of lack of hot water occur when the tap is opened.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite when the hot water tap is turned on, even though there is normal pressure and flow in the system.

    Cause: The flow meter does not send the flow signal to the control board, so it does not give the order to turn on the burner in DHW mode.

    First, check that the cold water inlet filter is clean: if it is clogged with limescale, the actual flow reaching the sensor decreases, even if it seems normal at the tap.

  • 02

    A flow fault warning or error code appears on the display.

    Cause: The PCB interprets the lack of signal from the sensor as the absence of water, even though the circuit has sufficient pressure.

    Check the pressure gauge of the boiler before replacing the part: if the pressure is below 1 bar, increase the pressure and repeat the domestic hot water test.

  • 03

    It does not recognize that there is demand when you open the tap: the burner does not start even with the water running.

    Cause: The internal mechanism of the flow meter (turbine or micro switch) does not close the circuit that alerts the PCB about the flow of water.

    Dismantle the flow meter and turn the turbine by hand: if it is stuck due to scale or does not turn freely, confirm that the fault is there.

  • 04

    The hot water comes out intermittently, it cuts off by itself and comes back without touching the faucet.

    Cause: A flow meter with the turbine partially blocked gives an intermittent signal instead of a continuous one, and the boiler turns the burner on and off following that irregular signal.

    Note if the cut coincides with pressure drops in the network, for example when another faucet in the house is open at the same time; if so, check the installation before declaring the part faulty.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Reference
S5720200
Batch code (PCB)
22B
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

What reference is engraved on this part?
S5720200, along with the batch code 22B, engraved on the flow meter's PCB.
Is this flow meter suitable for a Saunier Duval ThemaClassic boiler?
Yes, this flow meter is compatible with the ThemaClassic models C24E, C25E, F24E, and F25E.
When should this flow meter be replaced in a Saunier Duval boiler?
When the boiler does not detect water demand and does not ignite, or shows a flow fault.
How many models are compatible with the Saunier Duval Isofast F28E flow meter Ref. S5720200?
This flow meter is compatible with a total of 33 boiler models.
What range of boilers includes the Isofast F28E model?
The Isofast F28E model belongs to the Isofast range, which also includes Isofast C28E, Isofast C35E, Isofast Condens F30E, and Isofast Condens F35E.
What is the reference of the flow meter that I should look for my boiler?
The reference you need to look for is CCICF30E1.