Flow Meter / Flow Detector Saunier Duval Ref. S5720200 (Themaplus/Xtrafast series)
Flow detector for the domestic hot water circuit. According to two external sources, reference S5720200 corresponds to a Saunier Duval flow sensor/DHW, although it is not printed on this unit. The part is embossed with the marking 000010135190000 / 1471005001210, where the second block is compatible with a batch or date, not a catalog reference. It is replaced when flow detection fails.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S5720200
Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval ThemaClassic C24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic C25E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F25E | ThemaClassic | Contrasted |
| Saunier Duval Themafast C24E | Themafast | Contrasted |
| Saunier Duval Themafast C25E | Themafast | Contrasted |
| Saunier Duval Themafast C28E | Themafast | Contrasted |
| Saunier Duval Themafast Condens F24E | Themafast | Contrasted |
| Saunier Duval Themafast Condens F25 | Themafast | Contrasted |
| Saunier Duval Thematek C24E | Thematek | Contrasted |
| Saunier Duval Thematek F24E | Thematek | Contrasted |
| Saunier Duval Thematek S C24E | Thematek | Contrasted |
| Saunier Duval Thematek S F24E | Thematek | Contrasted |
| Saunier Duval Isofast C28E | Isofast | Contrasted |
| Saunier Duval Isofast C35E | Isofast | Contrasted |
| Saunier Duval Isofast F28E | Isofast | Contrasted |
| Saunier Duval Isofast Condens F30E | Isofast | Contrasted |
| Saunier Duval Isofast Condens F35E | Isofast | Contrasted |
| Saunier Duval Isomax C28E | Isomax | Contrasted |
| Saunier Duval Isomax F28E | Isomax | Contrasted |
| Saunier Duval Isomax Condens F35E | Isomax | Contrasted |
| Saunier Duval Isotwin C24EA | Isotwin | Contrasted |
| Saunier Duval Isotwin C28EA | Isotwin | Contrasted |
| Saunier Duval Isotwin F24E | Isotwin | Contrasted |
| Saunier Duval Isotwin F28EA | Isotwin | Contrasted |
| Saunier Duval Opalia C16E | Opalia | Contrasted |
| Saunier Duval Opalia F11E | Opalia | Contrasted |
| Saunier Duval Opalia F14E | Opalia | Contrasted |
| Saunier Duval Opalia F17E | Opalia | Contrasted |
| Saunier Duval Thema NOx F25 | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Thema Condens F24E | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Thema Condens F25 | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Semia F24 | Semia | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5720200 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the flow meter S5720200 resolves.
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
You turn on the hot water tap and it doesn't get hot, although the heating works without any issues.
Cause: The flow meter does not detect the flow of water and the PCB does not send the signal to turn on the burner in DHW mode.
Open the tap to maximum flow for a few seconds: if it heats up this way, the problem may be insufficient flow and not the part.
- 02
The burner does not start when you request domestic hot water, although it does ignite for heating.
Cause: Without the flow signal, the control board understands that there is no real demand for domestic hot water and does not start the cycle.
Check the cold water inlet filter before the flow meter: if it is clogged with limescale, it reduces the flow and gives the same symptom.
- 03
The hot water comes out intermittently, it cuts off and comes back without you having touched the tap.
Cause: The sensor turbine intermittently gets stuck due to scale or debris, causing the flow signal to fluctuate.
With the boiler accessible, check if the turbine shaft rotates freely when water passes through; if it gets stuck, clean it before replacing the part.
- 04
The display shows a warning related to the flow rate or the flow sensor.
Cause: The electronics compare the expected signal with the one received from the sensor and, if they do not match, it triggers that specific fault code.
Note the exact code and check the manual: some "lack of flow" warnings can also occur due to air in the circuit, not just because of the sensor.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S5720200 flow meter
- Catalogue reference
- S5720200
- Brand
- Saunier Duval
- Type of part
- Flow Detectors
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Embossed marking of the plastic plug
- 000010135190000 / 1471005001210
- Nature of the second block of digits
- Compatible with batch/date marking, not with catalog reference, according to label reading.
- Reference S5720200 (Saunier Duval flow sensor/DHW)
- S5720200 is a genuine Saunier Duval reference for a flow/domestic hot water sensor, according to 2 external sources; it does not appear printed on this unit.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Thematek S F24E Manual (PDF)Document © Saunier Duval, provided as a technical reference.