Flow Detector Saunier Duval Themaclassic F 25 E - Ref. S5720200
The Saunier Duval Themaclassic F 25 E flow detector - Ref. S5720200 detects the flow of water when a tap is opened and activates the ignition to produce domestic hot water. If it fails, you will notice that no hot water comes out even when the tap is open. This component is compatible with several boilers from the ThemaClassic range, such as the ThemaClassic C24E and F25E, among others. It is recommended to replace it when you experience a lack of hot water when opening the taps.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S5720200
Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval ThemaClassic C24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic C25E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F25E | ThemaClassic | Contrasted |
| Saunier Duval Themafast C24E | Themafast | Contrasted |
| Saunier Duval Themafast C25E | Themafast | Contrasted |
| Saunier Duval Themafast C28E | Themafast | Contrasted |
| Saunier Duval Themafast Condens F24E | Themafast | Contrasted |
| Saunier Duval Themafast Condens F25 | Themafast | Contrasted |
| Saunier Duval Thematek C24E | Thematek | Contrasted |
| Saunier Duval Thematek F24E | Thematek | Contrasted |
| Saunier Duval Thematek S C24E | Thematek | Contrasted |
| Saunier Duval Thematek S F24E | Thematek | Contrasted |
| Saunier Duval Isofast C28E | Isofast | Contrasted |
| Saunier Duval Isofast C35E | Isofast | Contrasted |
| Saunier Duval Isofast F28E | Isofast | Contrasted |
| Saunier Duval Isofast Condens F30E | Isofast | Contrasted |
| Saunier Duval Isofast Condens F35E | Isofast | Contrasted |
| Saunier Duval Isomax C28E | Isomax | Contrasted |
| Saunier Duval Isomax F28E | Isomax | Contrasted |
| Saunier Duval Isomax Condens F35E | Isomax | Contrasted |
| Saunier Duval Isotwin C24EA | Isotwin | Contrasted |
| Saunier Duval Isotwin C28EA | Isotwin | Contrasted |
| Saunier Duval Isotwin F24E | Isotwin | Contrasted |
| Saunier Duval Isotwin F28EA | Isotwin | Contrasted |
| Saunier Duval Opalia C16E | Opalia | Contrasted |
| Saunier Duval Opalia F11E | Opalia | Contrasted |
| Saunier Duval Opalia F14E | Opalia | Contrasted |
| Saunier Duval Opalia F17E | Opalia | Contrasted |
| Saunier Duval Thema NOx F25 | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Thema Condens F24E | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Thema Condens F25 | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Semia F24 | Semia | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5720200 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the flow meter S5720200 resolves.
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
You open the hot water tap and nothing happens: no ignition attempt or burner noise.
Cause: The detector is not sending a flow signal, so the boiler does not start.
Check that the water flow is reaching correctly by testing another faucet or checking the mains pressure before replacing the sensor.
- 02
The domestic hot water cuts off by itself a few seconds after opening the tap, even if you keep the tap open.
Cause: The detector loses the signal if the flow decreases slightly, and the boiler interprets that there is no longer a demand.
Test with the tap fully open: if it doesn't cut off with high flow, the fault is in the sensitivity of the detector.
- 03
The hot water comes in bursts, as if the boiler is turning the burner on and off several times in a row.
Cause: The internal contact of the detector is not stable and sends intermittent pulses to the boiler.
Check that the pre-filter before the detector is clean: dirt can cause intermittent ignitions.
- 04
The display shows a flow or water shortage error, even though the tap is open and with normal pressure.
Cause: The boiler does not receive confirmation of water flow from the detector, acting as if there is no flow.
Before changing it, bleed the domestic hot water circuit well: trapped air prevents the sensor from recognizing the actual flow.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S5720200 flow meter
- Catalogue reference
- S5720200
- Brand
- Saunier Duval
- Type of part
- Flow Detectors
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Thematek S F24E Manual (PDF)Document © Saunier Duval, provided as a technical reference.