Flow Detector Boiler Saunier Duval Isofast C 28 E - Ref. S5720200

Flow Detector Boiler Saunier Duval Isofast C 28 E - Ref. S5720200

Stock · 5 units

The Saunier Duval Isofast C 28 E boiler uses the flow detector S5720200, also known as flow switch. This part is responsible for detecting the flow of water when a tap is opened, thus activating the ignition for the production of domestic hot water (DHW). If the detector fails, you will notice that no hot water comes out, even with the tap open. It is compatible with models from the ThemaClassic, Themafast, Thematek, Isofast, Isomax, Isotwin, Opalia, and Thema Nox / Thema Condens ranges, among others. It is recommended to replace it when these symptoms occur.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    When opening the hot water tap, the boiler takes several seconds to ignite the flame.

    Cause: The flow detector does not send the signal on time because its paddle or turbine does not rotate properly.

    Open the tap to the maximum and check if the delay shortens; if so, it may just be insufficient flow in the installation.

  • 02

    The boiler does not ignite for hot water, although it works fine for heating.

    Cause: The flow detector does not detect the passage of water and the control board does not give the command to turn on the burner for domestic hot water.

    Check the cold water inlet filter, as if it is blocked, it reduces the flow below the minimum detection level.

  • 03

    The water comes out cold for a moment at first and then hot, as if it takes time to react.

    Cause: A flow detector with a jammed or dirty turbine responds slowly to the start of consumption.

    Close and open the tap several times in a row and observe if the delay is constant or if it only happens the first time.

  • 04

    The boiler turns on and off by itself several times while there is a hot water tap open.

    Cause: A flow detector that gives an intermittent signal causes the control unit to interpret that the consumption is interrupted and starts again.

    Check that the flow rate at that faucet is stable and does not depend on other simultaneous consumption in the house before replacing the part.

  • 05

    The display shows a fault code related to the flow of domestic hot water.

    Cause: The control board detects that the signal from the flow sensor does not match the expected parameters to allow the domestic hot water to flow.

    Note the exact code displayed by the boiler and compare it with the manual before deciding that it is the flow detector.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow Detectors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is the Saunier Duval Isofast C 28 E flow detector – Ref. S5720200 compatible with my Isofast C 28 E boiler?
Yes, the flow detector is compatible with the Isofast C 28 E boiler.
Does this flow detector work for the Isotwin C 24 E boiler?
Yes, the flow detector is compatible with the Isotwin C 24 E boiler.
How many boiler models are compatible with this flow detector?
The flow detector is compatible with a total of 33 boiler models.
What is the reference for this flow detector?
The reference for the flow detector is IFIC28EA.
Are there documented fault codes for this product?
No, there are no documented fault codes for this product.
Can I use this flow detector in a ThemaClassic boiler?
Yes, the flow detector is compatible with models from the ThemaClassic range, such as ThemaClassic C24E and ThemaClassic F25E.