Saunier Duval Flow Meter Flow Detector Themafast F 24 E Ref. S5720200
If no hot water comes out when you turn on the tap, you may need the Saunier Duval Flow Meter Flow Detector Themafast F 24 E Ref. S5720200. This flow detector is responsible for detecting the flow of water and activating the ignition for the production of domestic hot water. When it fails, the user experiences a lack of hot water, even when the tap is open. It is compatible with several boilers, including Themafast C24E, Themafast C25E, and Thema Nox F25, among others. It is recommended to replace it when this symptom occurs to restore the hot water supply.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S5720200
Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval ThemaClassic C24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic C25E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F25E | ThemaClassic | Contrasted |
| Saunier Duval Themafast C24E | Themafast | Contrasted |
| Saunier Duval Themafast C25E | Themafast | Contrasted |
| Saunier Duval Themafast C28E | Themafast | Contrasted |
| Saunier Duval Themafast Condens F24E | Themafast | Contrasted |
| Saunier Duval Themafast Condens F25 | Themafast | Contrasted |
| Saunier Duval Thematek C24E | Thematek | Contrasted |
| Saunier Duval Thematek F24E | Thematek | Contrasted |
| Saunier Duval Thematek S C24E | Thematek | Contrasted |
| Saunier Duval Thematek S F24E | Thematek | Contrasted |
| Saunier Duval Isofast C28E | Isofast | Contrasted |
| Saunier Duval Isofast C35E | Isofast | Contrasted |
| Saunier Duval Isofast F28E | Isofast | Contrasted |
| Saunier Duval Isofast Condens F30E | Isofast | Contrasted |
| Saunier Duval Isofast Condens F35E | Isofast | Contrasted |
| Saunier Duval Isomax C28E | Isomax | Contrasted |
| Saunier Duval Isomax F28E | Isomax | Contrasted |
| Saunier Duval Isomax Condens F35E | Isomax | Contrasted |
| Saunier Duval Isotwin C24EA | Isotwin | Contrasted |
| Saunier Duval Isotwin C28EA | Isotwin | Contrasted |
| Saunier Duval Isotwin F24E | Isotwin | Contrasted |
| Saunier Duval Isotwin F28EA | Isotwin | Contrasted |
| Saunier Duval Opalia C16E | Opalia | Contrasted |
| Saunier Duval Opalia F11E | Opalia | Contrasted |
| Saunier Duval Opalia F14E | Opalia | Contrasted |
| Saunier Duval Opalia F17E | Opalia | Contrasted |
| Saunier Duval Thema NOx F25 | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Thema Condens F24E | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Thema Condens F25 | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Semia F24 | Semia | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5720200 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the flow meter S5720200 resolves.
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
When opening the hot water tap, the boiler takes time to ignite or does not ignite.
Cause: The flow detector does not detect the flow of water and the boiler does not start in DHW mode.
Open the tap to the maximum and check if it ignites this way: if it works with a higher flow rate, suspect the detector before the boiler.
- 02
The hot water cuts off while you are showering, with the boiler turning on and off.
Cause: If the detector intermittently loses and regains the flow signal, the boiler shuts off the burner.
Check if the mixing tap is close to the minimum flow limit before declaring the detector faulty.
- 03
It is necessary to open the tap a lot for hot water to come out; with low flow, it does not heat.
Cause: The detector's turbine may be dirty or scaled and may require a higher flow rate to activate.
Check if the cold water flow from the tap is also weaker, indicating limescale in the system.
- 04
The boiler works well for heating but has a fault only with the domestic hot water.
Cause: The flow detector only operates in the domestic hot water circuit; a fault here does not affect the heating.
Confirm that the fault only occurs when requesting hot water and not during heating before purchasing the spare part.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S5720200 flow meter
- Catalogue reference
- S5720200
- Brand
- Saunier Duval
- Type of part
- Flow detectors
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days