Saunier Duval Flow Meter Flow Detector Themafast F 24 E Ref. S5720200

Saunier Duval Flow Meter Flow Detector Themafast F 24 E Ref. S5720200

If no hot water comes out when you turn on the tap, a technical diagnosis must confirm whether you need the Saunier Duval Flow Meter Detector Themafast F 24 E Ref. S5720200. This flow detector is responsible for detecting the flow of water and activating the ignition for the production of domestic hot water. When it fails, the user experiences a lack of hot water, even when the tap is open. It is compatible with several boilers, including Themafast C24E, Themafast C25E, and Thema Nox F25, among others. A technician must confirm through diagnosis whether it needs to be replaced when this symptom occurs to restore the hot water supply.

Type of part
Flow detectors
Catalogue reference
S5720200
Warranty
1 year
VAT included Stock · 6 units
Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Verified compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicVerified
Saunier Duval ThemaClassic C25EThemaClassicVerified
Saunier Duval ThemaClassic F24EThemaClassicVerified
Saunier Duval ThemaClassic F25EThemaClassicVerified
Saunier Duval Themafast C24EThemafastVerified
Saunier Duval Themafast C25EThemafastVerified
Saunier Duval Themafast C28EThemafastVerified
Saunier Duval Themafast Condens F24EThemafastVerified
Saunier Duval Themafast Condens F25ThemafastVerified
Saunier Duval Thematek C24EThematekVerified
Saunier Duval Thematek F24EThematekVerified
Saunier Duval Thematek S C24EThematekVerified
Saunier Duval Thematek S F24EThematekVerified
Saunier Duval Isofast C28EIsofastVerified
Saunier Duval Isofast C35EIsofastVerified
Saunier Duval Isofast F28EIsofastVerified
Saunier Duval Isofast Condens F30EIsofastVerified
Saunier Duval Isofast Condens F35EIsofastVerified
Saunier Duval Isomax C28EIsomaxVerified
Saunier Duval Isomax F28EIsomaxVerified
Saunier Duval Isomax Condens F35EIsomaxVerified
Saunier Duval Isotwin C24EAIsotwinVerified
Saunier Duval Isotwin C28EAIsotwinVerified
Saunier Duval Isotwin F24EIsotwinVerified
Saunier Duval Isotwin F28EAIsotwinVerified
Saunier Duval Opalia C16EOpaliaVerified
Saunier Duval Opalia F11EOpaliaVerified
Saunier Duval Opalia F14EOpaliaVerified
Saunier Duval Opalia F17EOpaliaVerified
Saunier Duval Thema NOx F25Thema Nox / Thema CondensVerified
Saunier Duval Thema Condens F24EThema Nox / Thema CondensVerified
Saunier Duval Thema Condens F25Thema Nox / Thema CondensVerified
Saunier Duval Semia F24SemiaVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the flow meter S5720200

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    When opening the hot water tap, the boiler takes time to ignite or does not ignite.

    Cause: The flow detector does not detect the flow of water and the boiler does not start in DHW mode.

    Open the tap to the maximum and check if it ignites this way: if it works with a higher flow rate, suspect the detector before the boiler.

  • 02

    The hot water cuts off while you are showering, with the boiler turning on and off.

    Cause: If the detector intermittently loses and regains the flow signal, the boiler shuts off the burner.

    Check if the mixing tap is close to the minimum flow limit before declaring the detector faulty.

  • 03

    It is necessary to open the tap a lot for hot water to come out; with low flow, it does not heat.

    Cause: The detector's turbine may be dirty or scaled and may require a higher flow rate to activate.

    Check if the cold water flow from the tap is also weaker, indicating limescale in the system.

  • 04

    The boiler works well for heating but has a fault only with the domestic hot water.

    Cause: The flow detector only operates in the domestic hot water circuit; a fault here does not affect the heating.

    Confirm that the fault only occurs when requesting hot water and not during heating before purchasing the spare part.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Uniclima internal SKU
DFSDTF24E
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
6 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently asked questions

Frequently asked questions about the flow meter S5720200

Is this flow detector compatible with the Saunier Duval Themafast F24E?
Yes, the Saunier Duval flow meter Detector Flujo Themafast F 24 E Ref. S5720200 is compatible with the Themafast F24E, which is listed among the compatible boilers.
What other boilers are compatible with this flow meter?
This flow meter is compatible with a total of 33 models, including the ThemaClassic, Themafast, Thematek, Isofast, Isomax, Isotwin, Opalia, Thema Nox / Thema Condens, and Semia ranges.
What is the reference for this flow meter?
DFSDTF24E is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
Are there documented fault codes for this product?
No, there are no documented fault codes for the Saunier Duval flow meter Themafast F 24 E.
Is this flow meter suitable for the Opalia range?
Yes, the flow meter is compatible with several models from the Opalia range, such as Opalia C16E, Opalia F11E, Opalia F14E, and Opalia F17E.
Can I use this flow meter in a boiler from the Isofast range?
Yes, the flow meter is compatible with models from the Isofast range, including Isofast C28E, Isofast C35E, Isofast F28E, Isofast Condens F30E, and Isofast Condens F35E.

Spare parts related to Saunier Duval Themafast

Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Saunier Duval Flow Meter Flow Detector Themafast F 24 E Ref. S5720200