Saunier Duval Flow Meter Flow Detector ThemaClassic F 25 E Ref. S5720200

Saunier Duval Flow Meter Flow Detector ThemaClassic F 25 E Ref. S5720200

Stock · 7 units

The Saunier Duval flow meter Detector Flujo ThemaClassic F 25 E Ref. S5720200 detects the flow of water when a tap is opened and activates the ignition to produce domestic hot water. When it fails, no hot water comes out even if the tap is open, which can be very inconvenient. This part is compatible with boilers from the ThemaClassic range, such as the ThemaClassic C24E and F25E, among others. It is advisable to replace the flow meter if you experience issues with the hot water supply.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    Dripping or moisture notes in the area of the flow sensor.

    Cause: The flow detector is made of plastic and can break due to pressure or impact.

    Dry the area, wait a few hours, and check if the moisture reappears on the sensor.

  • 02

    When turning on the hot water tap, the boiler does not ignite and remains cold.

    Cause: If the detector does not activate the flow, the boiler does not receive the signal to turn on.

    Before changing the sensor, make sure there is normal flow and that the inlet filter is not blocked.

  • 03

    The boiler does not prioritize domestic hot water while the heating is running.

    Cause: A flow detector that does not measure the domestic hot water consumption correctly prevents the boiler from managing the priority.

    Check in the boiler menu that the domestic hot water priority function is activated.

  • 04

    A warning appears on the screen related to the domestic hot water circuit when the tap is opened.

    Cause: The boiler detects erratic signals from the sensor as a fault in the domestic hot water circuit.

    Note the code that appears and compare it with the manual before considering that the detector is faulty.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Before purchasing
  • On the casing, a mold mark (116170) is embossed; it is a manufacturing mark of the plastic, not a manufacturer reference or a technical data: do not use it to request the part.
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is this flow detector compatible with the Saunier Duval ThemaClassic F25E?
Yes, the Saunier Duval DFTF25E flow detector is compatible with the ThemaClassic F25E boiler, which is listed among the confirmed models.
Can I use this flow meter in a Saunier Duval ThemaClassic C24E?
Yes, the Saunier Duval DFTF25E flow meter is compatible with the ThemaClassic C24E, as well as with other models in the same range.
Does this product work for the Themafast range?
Yes, the flow detector DFTF25E is compatible with several models from the Themafast range, including Themafast C24E and Themafast C25E.
How many models are compatible with the Saunier Duval DFTF25E flow meter?
The Saunier Duval DFTF25E flow meter is compatible with a total of 33 models from different ranges.
Are there documented fault codes for this flow meter?
No, there are no documented fault codes for the Saunier Duval DFTF25E flow meter.
Is this flow detector suitable for the Opalia range?
Yes, the flow detector DFTF25E is compatible with several models from the Opalia range, such as Opalia C16E and Opalia F11E.

Spare parts related to Saunier Duval Themafast

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Flow Meter Flow Detector ThemaClassic F 25 E Ref. S5720200