Saunier Duval Isofast F24-35E Flow Meter - Ref. S5720200

Saunier Duval Isofast F24-35E Flow Meter - Ref. S5720200

Stock · 5 units

Isofast is the range of boilers where the Saunier Duval Isofast F24-35E flow meter is installed. This part acts as a flow detector that senses the passage of water when a tap is opened, allowing ignition for the production of domestic hot water. If it fails, you will notice that no hot water comes out even when the tap is open. This flow meter is compatible with several models, including Isofast C28E, Isofast C35E, Isofast F28E, among others. It should be replaced when you stop receiving hot water when opening the taps.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler ignites well for heating, but it does not provide domestic hot water.

    Cause: The flow meter is responsible for detecting the demand for domestic hot water; if it does not send a signal, the boiler does not switch to hot water mode.

    Check that the fault only occurs with domestic hot water and not with heating, to rule out a general problem with the PCB.

  • 02

    A small bump or vibration is felt in the pipe when the tap is opened, before hot water comes out.

    Cause: The turbine of the flow meter may have abnormal friction due to limescale deposits, which delays the signal to the control unit.

    If the water in the area is hard, check for visible limescale in the inlet filter before replacing the part.

  • 03

    The domestic hot water stops coming out after a few seconds and then comes back on its own.

    Cause: The flow meter intermittently loses the flow signal, usually due to a turbine that gets stuck and then frees itself.

    Close and open the tap several times in a row; if the fault changes according to the speed of opening, the problem is with the flow meter and not with the gas valve.

  • 04

    There is no hot water coming out of any tap in the house, although the cold water works well in all of them.

    Cause: Without a signal from the flow meter, the boiler does not ignite the burner for domestic hot water at any tap.

    Before changing the flow meter, check the display for any fault code that indicates another source of the fault.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Silkscreened code line 1
00001035190000
Screen-printed code line 2 (unit variable)
1102023901310
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is this flow meter suitable for a Saunier Duval Isofast F35E?
Yes, the part is compatible with the Isofast F35E, as well as with the F28E, the Opalia F14E, the Themaclassic F24E, the Themafast F24E, the Thematek F24E, and the Condens F30E.
What fault does this flow meter resolve in the Saunier Duval Opalia F14E?
It detects the flow of water to activate the production of domestic hot water; it is replaced when the boiler does not start the DHW.
What codes are engraved on the flow meter of the Thematek F24E?