Flow Detector Saunier Duval Isofast F 28 E1 Ref. S5720200
The Saunier Duval Isofast F 28 E1 flow detector Ref. S5720200 is a flow switch that detects the flow of water when a tap is opened and activates the ignition for the production of domestic hot water. If it fails, you will notice that hot water does not come out even when the tap is open. This component is compatible with boilers from the ThemaClassic, Themafast, Thematek, Isofast, Isomax, Isotwin, Opalia, Thema Nox / Thema Condens, and Semia ranges, among others. It is recommended to replace it when you experience issues with hot water supply.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S5720200
Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval ThemaClassic C24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic C25E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F25E | ThemaClassic | Contrasted |
| Saunier Duval Themafast C24E | Themafast | Contrasted |
| Saunier Duval Themafast C25E | Themafast | Contrasted |
| Saunier Duval Themafast C28E | Themafast | Contrasted |
| Saunier Duval Themafast Condens F24E | Themafast | Contrasted |
| Saunier Duval Themafast Condens F25 | Themafast | Contrasted |
| Saunier Duval Thematek C24E | Thematek | Contrasted |
| Saunier Duval Thematek F24E | Thematek | Contrasted |
| Saunier Duval Thematek S C24E | Thematek | Contrasted |
| Saunier Duval Thematek S F24E | Thematek | Contrasted |
| Saunier Duval Isofast C28E | Isofast | Contrasted |
| Saunier Duval Isofast C35E | Isofast | Contrasted |
| Saunier Duval Isofast F28E | Isofast | Contrasted |
| Saunier Duval Isofast Condens F30E | Isofast | Contrasted |
| Saunier Duval Isofast Condens F35E | Isofast | Contrasted |
| Saunier Duval Isomax C28E | Isomax | Contrasted |
| Saunier Duval Isomax F28E | Isomax | Contrasted |
| Saunier Duval Isomax Condens F35E | Isomax | Contrasted |
| Saunier Duval Isotwin C24EA | Isotwin | Contrasted |
| Saunier Duval Isotwin C28EA | Isotwin | Contrasted |
| Saunier Duval Isotwin F24E | Isotwin | Contrasted |
| Saunier Duval Isotwin F28EA | Isotwin | Contrasted |
| Saunier Duval Opalia C16E | Opalia | Contrasted |
| Saunier Duval Opalia F11E | Opalia | Contrasted |
| Saunier Duval Opalia F14E | Opalia | Contrasted |
| Saunier Duval Opalia F17E | Opalia | Contrasted |
| Saunier Duval Thema NOx F25 | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Thema Condens F24E | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Thema Condens F25 | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Semia F24 | Semia | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5720200 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the flow meter S5720200 resolves.
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
When opening the hot water tap, the boiler does not ignite the burner.
Cause: The detector does not send the water flow signal that the PCB needs to start.
Check that the flow at the tap is normal, so as not to confuse a network pressure issue with the detector.
- 02
There is no water flow signal on the PCB even though the tap has been open for a while.
Cause: The internal sensor does not detect water movement, either due to mechanical blockage or a fault in the detector itself.
Check that the 4-pin connector is properly seated and free of corrosion before considering the detector faulty.
- 03
The detector does not send a signal to the PCB, and the boiler does not provide domestic hot water.
Cause: Without the signal from the sensor, the PCB does not distinguish a real demand for domestic hot water and does not command the ignition.
Try opening the tap with high and low flow: if it only turns on with high flow, there may be dirt in the mechanism rather than an electrical fault.
- 04
The boiler takes too long to provide hot water or delivers lukewarm water.
Cause: If the flow is around the minimum triggering point of the detector, the signal arrives late or intermittently, and the burner modulates poorly.
Measure the actual flow rate of the tap with a container and stopwatch to confirm that it exceeds the minimum required by the boiler.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S5720200 flow meter
- Catalogue reference
- S5720200
- Brand
- Saunier Duval
- Type of part
- Flow detectors
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Pressure range
- 0/4.5 bar
- Pin configuration
- 1: 0V / 2: +Vcc / 3: NC / 4: OUT
- Insulation class
- CLASS III
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Saunier Duval Thematek S F24E Manual (PDF)Document © Saunier Duval, provided as a technical reference.