Flow Detector Saunier Duval Isofast F 28 E1 Ref. S5720200

Flow Detector Saunier Duval Isofast F 28 E1 Ref. S5720200

Stock · 4 units

The Saunier Duval Isofast F 28 E1 flow detector Ref. S5720200 is a flow switch that detects the flow of water when a tap is opened and activates the ignition for the production of domestic hot water. If it fails, you will notice that hot water does not come out even when the tap is open. This component is compatible with boilers from the ThemaClassic, Themafast, Thematek, Isofast, Isomax, Isotwin, Opalia, Thema Nox / Thema Condens, and Semia ranges, among others. It is recommended to replace it when you experience issues with hot water supply.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    When opening the hot water tap, the boiler does not ignite the burner.

    Cause: The detector does not send the water flow signal that the PCB needs to start.

    Check that the flow at the tap is normal, so as not to confuse a network pressure issue with the detector.

  • 02

    There is no water flow signal on the PCB even though the tap has been open for a while.

    Cause: The internal sensor does not detect water movement, either due to mechanical blockage or a fault in the detector itself.

    Check that the 4-pin connector is properly seated and free of corrosion before considering the detector faulty.

  • 03

    The detector does not send a signal to the PCB, and the boiler does not provide domestic hot water.

    Cause: Without the signal from the sensor, the PCB does not distinguish a real demand for domestic hot water and does not command the ignition.

    Try opening the tap with high and low flow: if it only turns on with high flow, there may be dirt in the mechanism rather than an electrical fault.

  • 04

    The boiler takes too long to provide hot water or delivers lukewarm water.

    Cause: If the flow is around the minimum triggering point of the detector, the signal arrives late or intermittently, and the burner modulates poorly.

    Measure the actual flow rate of the tap with a container and stopwatch to confirm that it exceeds the minimum required by the boiler.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Pressure range
0/4.5 bar
Pin configuration
1: 0V / 2: +Vcc / 3: NC / 4: OUT
Insulation class
CLASS III
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is this flow detector Ref. S5720200 suitable for an Isofast F 28 E1?
Yes, it is also compatible with Condens F 30 E, Isofast F 28 E, F 30 E, F 35 E, Isomax F 28 E, Opalia F 14 E, and Themaclassic F 24 E.
What pressure range does this flow detector of the Isofast F 28 E1 support?
From 0 to 4.5 bar.
How many pins does the connector of this flow detector have?
4 pins: 0V, +Vcc, NC and OUT.
What is the function of this flow detector in the Isofast F 28 E1?
Detect the flow of water and send the signal to the boiler's PCB.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Flow Detector Saunier Duval Isofast F 28 E1 Ref. S5720200