Saunier Duval Isofast F35 E Flow Detector, Ref. S5720200

Saunier Duval Isofast F35 E Flow Detector, Ref. S5720200

Stock · 1 unit

In the Isofast range boilers, the Saunier Duval Isofast F35 E Flow Detector, Ref. S5720200, is a flow switch that detects the flow of water when a tap is opened and commands the ignition to produce domestic hot water. If it fails, you will notice that no hot water comes out even when the tap is open. This part is compatible with several models, including the Isofast C28E, Isofast C35E, Isofast F28E, among others. It should be replaced when you experience a lack of hot water when opening the taps.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not start the burner to provide hot water or heating, as if it does not detect that water is flowing.

    Cause: If there is no water flow signal, the control board does not activate the burner for safety reasons.

    Check the pressure of the installation and make sure there is no clogged pre-filter.

  • 02

    The hot water comes in and out, with brief and repeated interruptions while the tap remains open.

    Cause: A faulty flow switch can give intermittent readings, causing the burner to turn off and on for no apparent reason.

    Bleed the circuit and check that the pressure does not fluctuate before replacing the part.

  • 03

    A warning from the boiler appears related to the lack of water or flow, even though the system is full.

    Cause: The detector may indicate 'no flow' even though water is circulating properly through the system.

    Check that the pump is working and that no valve is partially closed before considering the part to be exhausted.

  • 04

    The problem only occurs with the domestic hot water, not with the heating.

    Cause: If the sensor is in the domestic hot water line, a fault will only be noticed in that service.

    Compare the behavior with heating and with domestic hot water separately before deciding to replace the part.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow Detectors
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Embossed number (fin)
116170
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is the flow detector Saunier Duval Isofast F35 E, Ref. S5720200, compatible with my boiler Saunier Duval Isofast F35 E?
Yes, the flow detector is compatible with the Isofast F35 E boiler, as it is on the list of confirmed models.
What other models are compatible with this flow detector?
The flow detector is compatible with a total of 33 models, including Isofast C28E, Isofast C35E, Isomax F28E, and ThemaClassic C24E, among others.
What is the reference for this flow detector?
The reference for the flow detector is DFIF35E1.
Are there any fault codes associated with this product?
No, there are no documented fault codes for this flow detector.
Can I use this flow detector in boilers from other brands?
No, this flow detector is specifically designed for the Saunier Duval models listed in the compatibility table.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Isofast F35 E Flow Detector, Ref. S5720200