Flow meter Saunier Duval Themafast Condens F 30 E - Ref. S5720200

Flow meter Saunier Duval Themafast Condens F 30 E - Ref. S5720200

Stock · 1 unit

If no hot water comes out when the tap is opened, the problem may lie with the flow meter Saunier Duval Themafast Condens F 30 E - Ref. S5720200. This part detects the flow of water and activates the water heater to provide domestic hot water. When it fails, the boiler does not initiate the heating process, preventing the flow of hot water. It is compatible with various models such as Themafast C24E, Themafast C25E, and Thema Nox F25, among others. It is recommended to replace it when noticing the absence of hot water despite the tap being open.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    There is no hot water or it takes a long time to heat up.

    Cause: If the flow detector takes time to signal or gives a weak signal, the boiler delays the burner ignition in DHW mode.

    Time how long it takes to heat the water and compare it with the usual; a delay of several seconds indicates insufficient flow in the sensor.

  • 02

    The boiler does not ignite the burner when a hot water tap is opened and remains in standby.

    Cause: Without the water flow signal, the PCB does not receive the command to start in DHW mode even though the other components are ready.

    Before changing the part, check that there is no aerator or faucet filter obstructed that reduces the flow at the faucet.

  • 03

    The production of hot water is interrupted and resumes on its own, with the boiler turning on and off repeatedly.

    Cause: An intermittent flow signal causes the control board to interpret that the demand comes and goes, and it turns the burner on and off accordingly.

    Note if the cuts coincide with the use of another faucet in the house; if so, check the overall pressure first before replacing the part.

  • 04

    The fault is more frequent in winter, with cold water, than in summer.

    Cause: With colder and harder water, the scale precipitates earlier inside the sensor, and this clogs the turbine or the detection mechanism sooner.

    If you notice that it worsens in the cold months, check the condition of the turbine before replacing the entire part: sometimes it is enough to clean it if it is not completely seized.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Embossed marking on the body
000010135190000 / 35108203901010
Batch code on PCB
394
Saunier Duval reference
S5720200
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is this flow meter compatible with the Saunier Duval Isotwin F 24 E?
Yes, it is on the list of compatible boilers for this part.
What function does this flow meter serve in the Opalia F 17 E?
Measure the flow of domestic hot water to activate the burner.
Is this flow meter suitable for the Isofast F 35 E?
Yes, it is on the list of compatible boilers for this part.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model