Saunier Duval Isofast F 30 E Flow Detector - Ref. S5720200
When you open the hot water tap, the Saunier Duval Isofast F 30 E Flow Detector - Ref. S5720200 activates to detect the flow of water and allow the ignition of the domestic hot water production system. If this part fails, you will notice that no hot water comes out even with the tap open. It is compatible with boilers from the ThemaClassic, Themafast, Thematek, Isofast, Isomax, Isotwin, and Opalia ranges, among others. It should be replaced when you experience a lack of hot water when opening the tap.
VAT included
Consult via WhatsAppSaunier Duval boilers compatible with reference S5720200
Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Saunier Duval ThemaClassic C24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic C25E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F24E | ThemaClassic | Contrasted |
| Saunier Duval ThemaClassic F25E | ThemaClassic | Contrasted |
| Saunier Duval Themafast C24E | Themafast | Contrasted |
| Saunier Duval Themafast C25E | Themafast | Contrasted |
| Saunier Duval Themafast C28E | Themafast | Contrasted |
| Saunier Duval Themafast Condens F24E | Themafast | Contrasted |
| Saunier Duval Themafast Condens F25 | Themafast | Contrasted |
| Saunier Duval Thematek C24E | Thematek | Contrasted |
| Saunier Duval Thematek F24E | Thematek | Contrasted |
| Saunier Duval Thematek S C24E | Thematek | Contrasted |
| Saunier Duval Thematek S F24E | Thematek | Contrasted |
| Saunier Duval Isofast C28E | Isofast | Contrasted |
| Saunier Duval Isofast C35E | Isofast | Contrasted |
| Saunier Duval Isofast F28E | Isofast | Contrasted |
| Saunier Duval Isofast Condens F30E | Isofast | Contrasted |
| Saunier Duval Isofast Condens F35E | Isofast | Contrasted |
| Saunier Duval Isomax C28E | Isomax | Contrasted |
| Saunier Duval Isomax F28E | Isomax | Contrasted |
| Saunier Duval Isomax Condens F35E | Isomax | Contrasted |
| Saunier Duval Isotwin C24EA | Isotwin | Contrasted |
| Saunier Duval Isotwin C28EA | Isotwin | Contrasted |
| Saunier Duval Isotwin F24E | Isotwin | Contrasted |
| Saunier Duval Isotwin F28EA | Isotwin | Contrasted |
| Saunier Duval Opalia C16E | Opalia | Contrasted |
| Saunier Duval Opalia F11E | Opalia | Contrasted |
| Saunier Duval Opalia F14E | Opalia | Contrasted |
| Saunier Duval Opalia F17E | Opalia | Contrasted |
| Saunier Duval Thema NOx F25 | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Thema Condens F24E | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Thema Condens F25 | Thema Nox / Thema Condens | Contrasted |
| Saunier Duval Semia F24 | Semia | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. S5720200 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the flow meter S5720200 resolves.
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
You turn on the hot water tap and the boiler does not ignite, even though the gas and electricity are fine.
Cause: The flow detector does not send the flow signal to the control board, so it does not give the ignition command.
Check that the water flow is sufficient, turn on the tap fully, and make sure that the domestic hot water inlet filter is clean before declaring the detector faulty.
- 02
The boiler ignites for hot water but turns off by itself when the tap is slightly reduced.
Cause: The diaphragm or membrane of the detector loses sensitivity with low flow rates and stops sending the signal steadily.
Open the tap to the maximum and observe if the cut takes longer to appear; if so, the problem lies in the sensitivity of the detector, not in the network pressure.
- 03
The water comes out hot and cold intermittently, without you having touched the faucet.
Cause: The detector contact bounces with circuit vibrations, causing the boiler to turn the burner on and off in a loop.
Check for any limescale or dirt in the pre-filter before the sensor: the same symptom of irregular shutdown can be caused by a dirty filter.
- 04
The display shows a warning related to the water flow, even though the tap is fully open.
Cause: The control board does not receive the pulse from the sensor even though the water circulates normally through the circuit.
Bleed the DHW circuit before changing the part: trapped air also prevents the detector's paddle from rotating.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Saunier Duval S5720200 flow meter
- Catalogue reference
- S5720200
- Brand
- Saunier Duval
- Type of part
- Flow detectors
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
- The number '116170' molded on the tab is clearly readable, but it is not a spare part reference: the same number appears on parts with a different SKU from this same batch, indicating that it is a mold or manufacturing cavity mark, not a part code.