Flow detector (flow switch) for the domestic hot water circuit. It alerts the boiler's electronics when there is a demand for hot water, so that the burner can be activated. It is replaced if there is no DHW despite having gas and pressure, or if the supply is intermittent. Compatible with the Thema (incl. Themafast), Isofast, Isomax, Isotwin, Isosplit, Condens, Opalia, and Semia ranges.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not provide domestic hot water even though there is gas and the pressure is correct.

    Cause: The flow detector does not detect the passage of water, so the PCB does not receive the command to turn on the burner.

    Measure the pressure of the installation on the manometer; if the pressure is low, the problem may not be with the detector.

  • 02

    The burner does not ignite when a tap is opened, but the heating works fine.

    Cause: This component only affects the domestic hot water circuit, so its fault does not impact the heating, which makes it easier to identify the problem.

    Check that the fault occurs in all the taps in the house and not just in one.

  • 03

    The hot water comes out intermittently, appearing and disappearing for no apparent reason.

    Cause: An unstable flow causes the PCB to modify the operation of the burner erratically, turning it on and off.

    Check if the cold water inlet filter is clean; a partial blockage can cause this issue.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Relief code, line 1 (tab)
0000103519000
Relief code, line 2 (tab)
1471320401410
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

Is the flow meter Saunier Duval Ref. S5720200 compatible with the Isofast Condens boiler?
Yes, it is compatible with the Isofast range, which includes Isofast Condens.
What problems can the Saunier Duval flow detector Ref. S5720200 solve in a Thema boiler?
Can you resolve the lack of domestic hot water despite having gas and pressure, or an intermittent supply of DHW?
Is this flow meter the same one used in other boilers from the Condens range?
The first recorded number may match that of another unit, indicating a common mold marking, not a unique identifying code.
How many models are compatible with the flow meter Saunier Duval Ref. S5720200?
This flow meter is compatible with a total of 33 models.
What is the reference for the Saunier Duval flow meter?
The reference of the flow meter is DFCTNF30B2.
Are there documented fault codes for this product?
No, there are no documented fault codes for this flow meter.