Flow meter Isofast F 28 E

Flow meter Isofast F 28 E

Stock · 5 units

Isofast F 28 E is a flow meter that detects the flow of water when a tap is opened and activates the ignition of the boiler to produce domestic hot water. When this part fails, you will notice that hot water does not come out even with the tap open. It is installed in boilers from the Isofast range, such as Isofast C28E, Isofast C35E, and Isofast F28E, among others. It is advisable to replace it when you experience these hot water supply issues.

VAT included

Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicContrasted
Saunier Duval ThemaClassic C25EThemaClassicContrasted
Saunier Duval ThemaClassic F24EThemaClassicContrasted
Saunier Duval ThemaClassic F25EThemaClassicContrasted
Saunier Duval Themafast C24EThemafastContrasted
Saunier Duval Themafast C25EThemafastContrasted
Saunier Duval Themafast C28EThemafastContrasted
Saunier Duval Themafast Condens F24EThemafastContrasted
Saunier Duval Themafast Condens F25ThemafastContrasted
Saunier Duval Thematek C24EThematekContrasted
Saunier Duval Thematek F24EThematekContrasted
Saunier Duval Thematek S C24EThematekContrasted
Saunier Duval Thematek S F24EThematekContrasted
Saunier Duval Isofast C28EIsofastContrasted
Saunier Duval Isofast C35EIsofastContrasted
Saunier Duval Isofast F28EIsofastContrasted
Saunier Duval Isofast Condens F30EIsofastContrasted
Saunier Duval Isofast Condens F35EIsofastContrasted
Saunier Duval Isomax C28EIsomaxContrasted
Saunier Duval Isomax F28EIsomaxContrasted
Saunier Duval Isomax Condens F35EIsomaxContrasted
Saunier Duval Isotwin C24EAIsotwinContrasted
Saunier Duval Isotwin C28EAIsotwinContrasted
Saunier Duval Isotwin F24EIsotwinContrasted
Saunier Duval Isotwin F28EAIsotwinContrasted
Saunier Duval Opalia C16EOpaliaContrasted
Saunier Duval Opalia F11EOpaliaContrasted
Saunier Duval Opalia F14EOpaliaContrasted
Saunier Duval Opalia F17EOpaliaContrasted
Saunier Duval Thema NOx F25Thema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F24EThema Nox / Thema CondensContrasted
Saunier Duval Thema Condens F25Thema Nox / Thema CondensContrasted
Saunier Duval Semia F24SemiaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter S5720200 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The heating works normally, but the domestic hot water is not heating up.

    Cause: The flow meter does not detect the flow of water and the boiler does not activate the DHW mode even though the burner is ready.

    Check the overall water installation pressure: if it is low, the sensor may not activate even if it is in good condition.

  • 02

    When opening a hot water tap, the boiler does not respond, as if it does not detect that it has been opened.

    Cause: The flow meter does not send the necessary signal, so the control unit does not know that there is a demand for domestic hot water.

    Test with another faucet in the house: if it starts working in one of them, the fault may be in that faucet or its piping, not in the flow meter.

  • 03

    An error warning related to flow or lack of water appears on the display of the boiler.

    Cause: The control unit interprets the lack of signal from the sensor as a flow fault and blocks the domestic hot water for safety.

    Before changing the part, make sure that the inlet shut-off valve is fully open: if it is partially closed, it may give the same warning.

  • 04

    The flow of hot water comes out intermittently or irregularly, rising and falling without reason.

    Cause: A partial blockage in the sensor due to scale causes unstable flow readings, which makes the boiler turn on and off.

    If the house has hard water, first check for visible limescale in the inlet filter before replacing the flow meter.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Brand
Saunier Duval
Type of part
Flow Detectors
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Type of component
Domestic hot water flow sensor, thermistor type (NTC), male thread 18 mm + female 28 mm
Flank code (line 1)
000010351900000
Flank code (line 2, reading not entirely reliable)
10912130701310
Batch code, line 1 (second reading)
0001035190000
Batch code prefix confirmed, line 2
10912137
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter S5720200

What type of component is the flow meter of the Isofast F 28 E?
It is a domestic hot water flow sensor of thermistor type (NTC), with a male thread of 18 mm and a female thread of 28 mm.
What code is on the tab of the flow meter of the Isofast F 28 E?
The code is 000010351900000, which can be clearly read on the label.
Is the flow meter CSDIF28E compatible with the Thema Condens F 24 E?
Yes, the Thema Condens F 24 E is on the list of compatible boilers.
How many models are compatible with the Isofast F 28 E flow meter?
A total of 33 models are compatible with this flow meter.
Which ranges of boilers are compatible with the Isofast F 28 E flow meter?
The compatible ranges include ThemaClassic, Themafast, Thematek, Isofast, Isomax, Isotwin, Opalia, Thema Nox / Thema Condens, and Semia.
Does this flow meter have documented fault codes?
No, there are no documented fault codes for this product.

Spare parts related to Saunier Duval Themafast

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model