Saunier Duval Isofast F 35 E flow meter Ref. S5720200

Saunier Duval Isofast F 35 E flow meter Ref. S5720200

The Saunier Duval Isofast F 35 E flow meter Ref. S5720200 detects the flow of water when a tap is opened and activates the ignition to generate domestic hot water. When it fails, no hot water comes out even when the tap is open. This part is compatible with boilers from the Isofast range, such as the Isofast C28E, Isofast C35E, and Isofast F28E, among others. A technician must confirm through diagnosis whether it is necessary to replace the flow meter when these symptoms of lack of hot water occur.

Type of part
Flow detectors
Catalogue reference
S5720200
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Saunier Duval boilers compatible with reference S5720200

Flow meter with reference S5720200. 33 confirmed compatibilities: ThemaClassic C24E and ThemaClassic C25E.

Verified compatibility

Boiler modelFamilyVerification
Saunier Duval ThemaClassic C24EThemaClassicVerified
Saunier Duval ThemaClassic C25EThemaClassicVerified
Saunier Duval ThemaClassic F24EThemaClassicVerified
Saunier Duval ThemaClassic F25EThemaClassicVerified
Saunier Duval Themafast C24EThemafastVerified
Saunier Duval Themafast C25EThemafastVerified
Saunier Duval Themafast C28EThemafastVerified
Saunier Duval Themafast Condens F24EThemafastVerified
Saunier Duval Themafast Condens F25ThemafastVerified
Saunier Duval Thematek C24EThematekVerified
Saunier Duval Thematek F24EThematekVerified
Saunier Duval Thematek S C24EThematekVerified
Saunier Duval Thematek S F24EThematekVerified
Saunier Duval Isofast C28EIsofastVerified
Saunier Duval Isofast C35EIsofastVerified
Saunier Duval Isofast F28EIsofastVerified
Saunier Duval Isofast Condens F30EIsofastVerified
Saunier Duval Isofast Condens F35EIsofastVerified
Saunier Duval Isomax C28EIsomaxVerified
Saunier Duval Isomax F28EIsomaxVerified
Saunier Duval Isomax Condens F35EIsomaxVerified
Saunier Duval Isotwin C24EAIsotwinVerified
Saunier Duval Isotwin C28EAIsotwinVerified
Saunier Duval Isotwin F24EIsotwinVerified
Saunier Duval Isotwin F28EAIsotwinVerified
Saunier Duval Opalia C16EOpaliaVerified
Saunier Duval Opalia F11EOpaliaVerified
Saunier Duval Opalia F14EOpaliaVerified
Saunier Duval Opalia F17EOpaliaVerified
Saunier Duval Thema NOx F25Thema Nox / Thema CondensVerified
Saunier Duval Thema Condens F24EThema Nox / Thema CondensVerified
Saunier Duval Thema Condens F25Thema Nox / Thema CondensVerified
Saunier Duval Semia F24SemiaVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. S5720200 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference S5720200. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the flow meter S5720200

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    With the hot water tap fully open, the flow is weak only when requesting hot water, not with cold water.

    Cause: There is limescale buildup inside the body of the sensor that narrows the water flow.

    Compare the pressure in a cold water tap with that of hot water; if it only decreases in hot water, the restriction is in the sensor.

  • 02

    Every time you turn on the tap, the burner takes several more seconds to ignite.

    Cause: The detector requires more flow than normal to close the contact, which indicates that the turbine is worn out.

    Open the tap suddenly and at high flow; if the delay is significantly reduced, the part is losing sensitivity.

  • 03

    The boiler does not enter domestic hot water mode even with the tap fully open, although it works well in heating mode.

    Cause: Without a flow signal from the detector, the control unit does not know that there is a demand for domestic hot water and does not activate the burner.

    Test more than one tap in the house; if none of them activates the domestic hot water mode, first isolate whether it is the sensor or the control board.

  • 04

    From time to time, the boiler starts heating water on its own, without anyone having opened a tap.

    Cause: The detector may get stuck indicating water flow even when there is none, due to wear or dirt in the turbine.

    Close all the hot water shut-off valves and check if it still starts; first rule out a leak in the installation.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval S5720200 flow meter

Catalogue reference
S5720200
Uniclima internal SKU
CSDIF35E
Brand
Saunier Duval
Type of part
Flow detectors
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently asked questions

Frequently asked questions about the flow meter S5720200

Is this Saunier Duval Isofast F 35 E flow meter (Ref. CSDIF35E) compatible with the ThemaClassic F24E?
Yes, the ThemaClassic F24E is on the list of compatible boilers.
Can I use the Saunier Duval Isofast F 35 E flow meter in an Opalia F17E?
Yes, the Opalia F17E is one of the compatible models.
Does the Saunier Duval Isofast F 35 E flow meter work for the Isomax range?
Yes, the models from the Isomax range such as Isomax F28E and Isomax Condens F35E are compatible.
How many models are compatible with the Saunier Duval Isofast F 35 E flow meter?
The flow meter is compatible with a total of 33 models.
Are there documented fault codes for the Saunier Duval Isofast F 35 E flow meter?
No, there are no documented fault codes for this product.