Air Pressure Switch VCM 242/1 E - Cod. 605.99390

Air Pressure Switch VCM 242/1 E - Cod. 605.99390

Stock · 32 units

Air pressure switch (also called differential or flue pressure switch), a component that compares the pressure generated by the fan with a set value and allows or blocks the burner ignition based on the result. It is replaced when the boiler does not ignite, locks with the fan running, or shows a draft fault error. Factory setting: 135/120 Pa.

VAT included

Compatibility

Vaillant boilers compatible with reference 050557

Pressure switch with reference 050557. Six confirmed compatibilities: VCM 182 E and VCM 182/1 E.

Proven compatibility

Boiler modelFamilyVerification
Vaillant VCM 182 EVCM TurboblockContrasted
Vaillant VCM 182/1 EVCM TurboblockContrasted
Vaillant VCM 242 EVCM TurboblockContrasted
Vaillant VCM 242/1 EVCM TurboblockContrasted
Vaillant VCM 282 EVCM TurboblockContrasted
Vaillant VCM 282/1 EVCM TurboblockContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 050557 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 050557. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 050557 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler locks up with the fan running at full speed and without igniting the flame.

    Cause: The differential pressure switch does not receive sufficient depression even though the extractor is operating at its maximum capacity.

    Check that the air intake grille and the flue outlet are not obstructed by dirt or, in winter, by ice.

  • 02

    The flue fault appears right after cleaning or inspecting the boiler.

    Cause: When handling the flue pipe, it is easy for the silicone tube of the pressure switch to become dislodged or pinched.

    Visually check the path of the silicone tube of the pressure switch after any intervention in the duct.

  • 03

    The boiler works well almost always, but it fails just after a power cut or when turning it back on.

    Cause: A pressure switch at the limit of its travel may not stabilize in time on the first attempt after reconnecting the power.

    Note whether the fault occurs always on the first ignition of the day or after power supply interruptions.

  • 04

    The extractor sounds different than usual just before the boiler locks out.

    Cause: A fan that loses revolutions does not generate the pressure differential that the pressure switch needs to operate correctly.

    Listen to see if the extractor sounds more strained or weaker than usual before ruling out the pressure switch.

Fault codes from Vaillant that this part resolves.

CodeFaultDiagnosis and solution
F.33Pressure switch faultThe air pressure switch does not switch (does not close/open when the fan starts/stops) due to obstruction in the pressure intake/hose or a defective pressure switch; check continuity by applying pressure and inspect hoses, pitot intake, and air-smoke draft.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Vaillant 050557 pressure switch datasheet

Catalogue reference
050557
Brand
Vaillant
Type of part
Pressure switches
Units in stock
32 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Component code
605.99390
Switching pressure (open/close)
135/120 Pa
Contact current/voltage
0.2(0.1)/30~
Additional code
00FDHJ
Batch code / short reference
JV 050546 / J16
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch 050557

Is this air pressure switch suitable for the VCM 242/1 E boiler?
Yes, the VCM 242/1 E air pressure switch (reference PTVCM242) is compatible with the VCM 242/1 E model.
What fault indicates that the air pressure switch of the VCM 242/1 E needs to be replaced?
It should be replaced when the boiler does not ignite, gets blocked with the fan running, or shows the fault code F.33.
What pressure does the air pressure switch of the VCM 242/1 E switch?
Switches at 135/120 Pa for opening/closing, according to the product label.
How many models are compatible with the VCM 242/1 E air pressure switch?
This pressure switch is compatible with a total of 6 models from the VCM Turboblock range.
What other models are compatible with the VCM 242/1 E air pressure switch?
The compatible models are: VCM 182 E, VCM 182/1 E, VCM 242 E, VCM 242/1 E, VCM 282 E, and VCM 282/1 E.

Spare parts related to Vaillant VCM Turboblock

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Air Pressure Switch VCM 242/1 E - Cod. 605.99390