Fagor FE 24 EMA N Circulating Pump Grundfos UP15-50 A0 /FG Ref. N47G005M0
The N47G005M0 is a Grundfos UP15-50 A0 /FG circulator pump that circulates water through the heating circuit of the boiler. It is confirmed for the Fagor FE 24 EMA N, FE 24 EC-1 N, and FEE 24 MA N boilers, as well as other Fagor FE and FEE models on the compatibility list. It operates at 230 V · 50 Hz and 90 W. It is sold refurbished, tested, and with a 1-year warranty.
- Type of part
- Pumps
- Status
- Refurbished
- internal SKU
- BOM009
- Warranty
- 1 year
Compatible Fagor boilers
Circulating pump. Ten verified compatibilities: FE 24 EMA N and FE 24 EMA-1 N.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fagor FE 24 EMA N | Fagor | Contrasted |
| Fagor FE 24 EMA-1 N | Fagor | Contrasted |
| Fagor FE 24 EMA-1 B | Fagor | Contrasted |
| Fagor FE 24 EC-1 N | Fagor | Contrasted |
| Fagor FE 24 EC-1 B | Fagor | Contrasted |
| Fagor FEE 24 MA N | Fagor | Contrasted |
| Fagor FEE 24 MA-1 N | Fagor | Contrasted |
| Fagor FEE 24 MA-1 B | Fagor | Contrasted |
| Fagor FEE 26 MA-1 N | Fagor | Contrasted |
| Fagor FEE 26 MA-1 B | Fagor | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- With the boiler disconnected from the power supply, locate the circular label on your current pump motor, which has a plug in the center.
- Read the complete marking and compare it with that of this unit: Type UP15-50 A0 /FG, P/N 59505451, PC 0509FG and, under the Fagor logo, N47G005M0. The entire designation must match.
- Check the electrical data on the label: 230 V ~ 50 Hz, 2 µF, 0.39 A, 90 W, IP 42, class H, and max. 3 bar.
- Compare the hydraulic body, cable, and electrical connector of your pump with the photos. If they are different, please consult us before ordering it.
- Check that your boiler model is on the list of compatible ones. If it is not listed or the designation does not match exactly, call us at 911 17 77 77 with your boiler model and a photo of the label.
Symptoms that require diagnosis in the circulation pump
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pump does not start.
Cause: Possible shaft blockage, which can be checked by turning it by hand.
A technician can check if the shaft turns manually: with the power off and the circuit isolated on both sides of the pump, remove the indicator plug from the center of the label. In the FEE 24 MA, also check that the boiler is not disconnected from the power supply: the anti-seizing safety of the pump only operates with the boiler connected.
- 02
Damaged motor or pump after running without water
Cause: Prolonged operation without water circulation or without the minimum inlet pressure.
Before starting the pump, check that the circuit is full, bled of air, and under pressure.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Fagor circulator pump
- Uniclima internal SKU
- BOM009
- Brand
- Fagor
- Type of part
- Pumps
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Reference
- N47G005M0
- Grundfos designation
- UP15-50 A0 /FG
- Marked P/N
- 59505451
- Marked PCB
- 0509FG
- Manufacturer of the pump
- Grundfos, labeled with the reference Fagor
- Voltage and frequency
- 230 V ~ · 50 Hz
- Power (P1)
- 90 W
- Maximum current (Imax)
- 0.39 A
- Condenser
- 2 µF
- Protection
- IP 42
- Class (label)
- H
- TF (label)
- 95
- Maximum pressure
- 3 bar
- Presentation
- Hydraulic body and motor, with cable and electrical connector
- Status
- Refurbished and tested, with a 1-year warranty.
- Do not confuse with UP 15-50 AO F6: Different Grundfos designation (AO F6, not A0 /FG). Do not consider it equivalent: always compare the full marking on the label.
- Do not confuse with UPS 15-50: Grundfos series with another designation (UPS instead of UP). Compare the full designation.
- Do not confuse with 59505451 and 0509FG: P/N and PC marked on the Grundfos label of the pump. The Fagor reference is N47G005M0.
- Do not confuse with 912011218 and similar codes: Nine-digit codes of the Fagor boiler models from the compatibility list. They are not pump codes.
- Please consult us before purchasing if your boiler is: A. O. Smith JLG24-EB (912470034)