Wilo RS15/5-3 O Circulating Pump · 4511685 for Fagor FE-24 EN and CE-24 EN
It circulates hot water through the radiators. It is suspected if the radiators remain cold with the boiler on, if there are noises or vibrations, or if the rotor gets stuck after long summer shutdowns.
- Type of part
- Pumps
- Status
- Refurbished
- Catalogue reference
- 4511685
- Warranty
- 1 year
Wilo boilers compatible with reference 4511685
Circulating pump with reference 4511685. Two confirmed compatibilities: Fagor FE-24 EN and Fagor CE-24 EN. There are three other models that we are still verifying.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Wilo Fagor FE-24 EN | Wilo | Contrasted |
| Wilo Fagor CE-24 EN | Wilo | Contrasted |
Models pending verification
These models are associated with this reference, but we have not finished verifying them yet, so we do not consider them compatibleIf your boiler is one of them, send us a photo of the part you are going to replace and we will verify it before you purchase.
| Wilo Fagor Super Compact FE 24 E | Wilo | Unconfirmed |
|---|---|---|
| Wilo Fagor Contract Mini CE 24 E | Wilo | Unconfirmed |
| Wilo Fagor Eco Mini FEB 24 AR | Wilo | Unconfirmed |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 4511685 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Look at the motor label: it should say Wilo RS15/5-3 or the code 4511685 (in our unit, 4513777 is also listed).
- Compare the voltage and speeds: 230 V · 50 Hz, three speeds (1600 / 2000 / 2200 min⁻¹) and capacitor of 2.6 µF · 400 VDB.
- Don't confuse it with other Wilo models from the RS series, such as the RS 15/6: they have a different designation.
- Check on the PCB of your boiler that it is a Fagor FE-24 EN or CE-24 EN. If it is a FE 24 E without N, compare the designation of your pump first.
- If they match, call us at 911 17 77 77 with your boiler model and we will reserve it for you.
Symptoms that require diagnosis in the circulator pump 4511685
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Cold radiators with the boiler on
Cause: it is associated with the pump RS15/5-3 in the FE24E technical sheet.
- 02
Strange noises or vibrations while operating
Cause: it includes it among the faults in its technical sheet.
- 03
Stuck rotor after long summer shutdowns
Cause: it includes it among the faults in its technical sheet; check the diagnostic note.
- 04
Small water leaks in the pump body
Cause: it includes it among the faults in its technical sheet.
- 05
Boiler lockout due to lack of circulation
Cause: it includes it among the faults in its technical sheet, as a general lock due to lack of circulation in the circuit.
- 06
The boiler locks with fault code F03: the circuit pressure drops below 0.6 bar or rises above 2.8 bar.
Cause: Circuit pressure out of range: low water, air in the circuit, or excess pressure.
Check the pressure on the display (it should be above 1 bar). If it happens again, have a technician check it.
- 07
F4 appears: the boiler locks due to overheating and the water circulates poorly.
Cause: Lack of water circulation due to air, low pressure, or a weak pump.
Bleed the air from the radiators and check the pressure. If the warning returns, have a technician check the pump.
- 08
The boiler locks and displays F3/F03: heating pressure out of range.
Cause: Lack of water, excess pressure, leak, or faulty pressure sensor.
Check the cold pressure with the manometer and adjust it according to the manual. If it returns, have a technician check it.
- 09
The boiler stops due to overheating (F4 or F7).
Cause: Poor circulation, air in the system, worn-out pump, or faulty sensor.
Check the bleed and the pressure. If it repeats, have a technician check it.
- 10
When turned on, the pump operates in cycles and the heating does not heat.
Cause: Insufficient water flow in the circuit: air, low pressure, or pump without flow.
Bleed the radiators and fill the circuit to 1 bar. If it continues, have a technician check it.
Wilo fault codes that require diagnosis
| Code | Fault | Technical checks |
|---|---|---|
| F4 | Safety thermostat cut-off due to overheating. | Check the pressure, bleed it, and ensure that the pump is circulating the water. If the pump is not circulating properly, point to the pump. Have a technician check it. |
| F3 / F03 | Heating circuit pressure out of range: the boiler locks out. | Check the cold pressure with the manometer and adjust it according to the manual. If it happens again, have a technician check it. |
| F23 | Circulation anomaly, parameters or sensors. | Bleed, check the pressure, and request a diagnosis if it returns. It may indicate a pump with low power. |
| F3 | Heating circuit pressure out of range, or lack of water flow when turning on the boiler. | Check the pump if the pressure is correct and water is not circulating. Check the pressure and bleed the radiators. If the issue persists, have a technician check it. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Technical sheet: Wilo 4511685
- Catalogue reference
- 4511685
- Uniclima internal SKU
- BOM011
- Brand
- Wilo
- Type of part
- Pumps
- Units in stock
- 0 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Power supply
- 230 V; 50 Hz
- Marked capacitor
- 2.6 uF; 400 VDB
- P1 speeds I/II/III
- 42/60/84 W
- Current I/II/III
- 0.18/0.27/0.37 A
- Speed I/II/III
- 1600/2000/2200 min-1
- Protection
- PN6; IP44; Class F; TF95
- Inventory — Type of spare part
- Pumps
- Inventory — Condenser
- 2.6 μF; 400 VDB
- Inventory — Application indicated in inventory
- FE-24 EN CE-24 EN
- Additional data — Function
- The heating water circulates.
- Additional information — Power supply
- 230 V
- Additional data — Speeds
- 3 · 1600 / 2000 / 2200 min⁻¹ ·
- Additional data — Pressure and protection
- PN6 · IP44 ·
- Identification — Marked designation
- RS15/5-3 or
- Identification — Marked code
- 4511685
- Identification — Marked code
- 4513777
- Technical sheet: Power supply
- 230 V; 50 Hz
- Technical sheet: Marked capacitor
- 2.6 uF; 400 VDB
- P1 speeds I/II/III
- 42/60/84 W
- Technical sheet: Current I/II/III
- 0.18/0.27/0.37 A
- Speed I/II/III
- 1600/2000/2200 min-1
- Technical sheet: Protection
- PN6; IP44; Class F; TF95
- Inventory data — Type of spare part
- Pumps
- Inventory data — Condenser
- 2.6 μF; 400 VDB
- Inventory data — Application indicated in inventory
- FE-24 EN
- Inventory data — Application indicated in inventory
- CE-24 EN
- Pending applications to verify
- Statements from (documentation 23/10/2026; revision 24/10/2026), pending confirmation by the manufacturer. Check reference, revision, and serial number before use: FAGOR SUPER COMPACT FE 24 E · FAGOR CONTRACT MINI CE 24 E · FAGOR ECO MINI FEB 24 AR This offer is limited to the motor; it does not certify the compatibility of the hydraulic assembly.
- sometimes the shaft can be turned by hand after removing the central plug if it has become stuck.
- To confirm: Fagor Super Compact FE 24 E — with 4511685 and with RS15/5-3
- To confirm: Fagor Contract Mini CE 24 E — 1 origin: (4511685)
- To confirm: Fagor Eco Mini FEB 24 AR — 1 origin: (4511685)
- Do not confuse: RS 15/6 — Wilo Pump RS 15/6 SLO, which a spare parts list shows for the FE 24 E — Another designation of the RS series: it is not the RS15/5-3 or
- Without confirmation: AS0015925 with 4511685: always compare the full designation and the label code.
- To confirm: Code 4511685 linked to the Wilo RS15/5-3 pump. No official breakdown. Discrepancy in the FE 24 E: one list shows the RS 15/6 SLO and the RS15/5-3. Confirms FE-24 EN and CE-24 EN.