Cointra Supra SP 27 EI Circulating Pump - Grundfos UP 15-60 A0 - Ref. 59926512
RefurbishedCointraPumpsGrundfos

Cointra Supra SP 27 EI Circulating Pump - Grundfos UP 15-60 A0 - Ref. 59926512

Stock · 3 units

Grundfos UP 15-60 A0 circulator pump (P/N 59926512), originally installed in Cointra Supra SP21EI, SP24I, and SP27EI boilers. It moves the water in the heating circuit. It operates at 230V-50Hz, with a maximum pressure of 3 bar and insulation class H. It is replaced when it does not start, makes noise, or the boiler stops heating due to lack of circulation.

VAT included

Compatibility

Compatible Cointra boilers

Circulating pump. Three confirmed compatibilities: SP21EI and SP24I.

Proven compatibility

Boiler modelFamilyVerification
Cointra SP21EISUPRAContrasted
Cointra SP24ISUPRAContrasted
Cointra SP27EISUPRAContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulation pump resolves

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The radiators are not heating or take a long time to do so even though the burner is working.

    Cause: The pump does not move the water with sufficient flow, preventing heat from circulating through the system.

    Bleed the radiators and make sure the shut-off valves are open before changing the pump; air in the circuit can cause the same problem.

  • 02

    A buzzing, whistling, or vibrating sound is heard in the pump.

    Cause: The noise may be caused by trapped air in the impeller or by a worn bearing.

    Bleed the air from the circuit using the pump's bleed valve before assuming that the noise is mechanical.

  • 03

    The pump does not start, it is stopped and there is no vibration or heat.

    Cause: It is common for the shaft to seize up due to sediment or lack of use after the summer.

    With the boiler turned off, try to turn the shaft by hand with a flat screwdriver through the front slot; if it is stuck, it can be unlocked without the need to replace the pump.

  • 04

    Is there water or moisture in the area of the pump?

    Cause: The mechanical seal of the shaft loses tightness over time and starts to leak water.

    Dry the area and check in a few hours if the moisture reappears at the joint of the pump, to rule out that it comes from another nearby joint.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Cointra circulator pump data sheet

Brand
Cointra
Type of part
Pumps
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Type/model
UP 15-60 A0
P/N (product number Grundfos)
59926512
Production code (PC)
0642BX
Voltage
230V ~ 50Hz
Condenser
2.5 µF
Protection rating
IP 44
Thermal class of the liquid
TF 95
Motor insulation class
Class H
Maximum working pressure
Max. 3 bar
Nominal current
0.39 A
Power P1
90 W
Efficiency
Low Energy
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the circulation pump

Is this circulation pump the one originally installed in the Cointra Supra SP27EI?
Yes, it is the Grundfos UP 15-60 A0 (P/N 59926512) pump that Cointra installs as standard in the Supra SP27EI, as well as in the SP21EI and SP24I.
What code should I check on the label to get the right Grundfos pump?
The P/N 59926512, printed on the label of the Grundfos UP 15-60 A0 pump.
What is the voltage and maximum pressure that the pump of the Cointra Supra SP27EI operates at?
At 230V-50Hz, with a maximum pressure of 3 bar and insulation class H.
When should the circulation pump of the Supra SP27EI be replaced?
When it doesn't start, it makes noise or the boiler stops heating due to lack of water circulation.
Is this Grundfos UP 15-60 A0 pump energy-efficient?
Yes, the label marks it as "Low Energy."

Spare parts related to Cointra SUPRA

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Cointra Supra SP 27 EI Circulating Pump - Grundfos UP 15-60 A0 - Ref. 59926512