Grundfos Circulating Pump Cointra Edyco ED-21 EI P/N 59935511
Three-speed circulating pump manufactured by Grundfos for Cointra boilers (Edyco ED-21, Europa SPI 21, Supra SP 21, Supra SPC 21 EI), marketed under the Cointra brand. It circulates the heating circuit water between the boiler and the radiators. It should be replaced when it doesn't rotate, makes noise, leaks from the shaft, or the flow is insufficient at any of the three speeds.
VAT included
Consult via WhatsAppCointra boilers compatible with reference 9158441
Circulating pump with reference 9158441. Eight confirmed compatibilities: EDYCO ED 21 EI and EDYCO ED 21 I.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Cointra EDYCO ED 21 EI | Cointra Edyco ED 21 | Contrasted |
| Cointra EDYCO ED 21 I | Cointra Edyco ED 21 | Contrasted |
| Cointra SUPRA SP 21 EI | Cointra Supra / Supra Compact 21 | Contrasted |
| Cointra SUPRA SP 21 I | Cointra Supra / Supra Compact 21 | Contrasted |
| Cointra SUPRA SPC 21 EI (Supra Compact 21 EI) | Cointra Supra / Supra Compact 21 | Contrasted |
| Cointra EUROPA SPI 21 EI | Cointra Europa SPI 21 | Contrasted |
| Cointra EUROPA SPI 21 I | Cointra Europa SPI 21 | Contrasted |
| Cointra CTS 24/60 EI | Cointra CTS 24/60 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 9158441 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 9158441. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulator pump 9158441 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler turns on but the water doesn't reach the radiators properly.
Cause: The pump does not rotate or rotates very slowly and cannot move the water.
Change the speed on the selector before considering replacing the pump; sometimes only one position fails.
- 02
The flow is weak at a specific speed but not at the others.
Cause: There may be accumulated scale in the impeller that causes it to rub more at certain revolutions than at others.
Measure the flow rate at the three speeds before deciding that the pump is faulty.
- 03
Noise or vibration transmitted to the nearby pipe.
Cause: There may be air in the pump body or the bearing is worn out.
Bleed the air through the front screw and try to turn it on again before replacing it.
- 04
Water is leaking from the pump shaft.
Cause: The mechanical seal has worn out and no longer seals properly.
Dry the area and check if the dripping reappears right at the shaft, not at a nearby flange.
Fault codes for Cointra that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| LED 2 Off; LED 3 Slow Flashing (EDYCO 21 I / EDYCO 21 EI) | Lack of water in the heating circuit or blocked pump. | If the circulating pump is blocked or not delivering flow, the hydraulic pressure switch does not close and the control board indicates this alarm; check by supplying power to the pump (≈230 V) on demand and verifying rotation/consumption and closure of the pressure switch. |
| 5 (SUPRA SP 1.21/21/24/27 and SUPRA SPC 21 EI) | Indicates lack of water or blocked pump. | A blocked pump or one without flow causes a lack of circulation, and the equipment displays signal 5; check the voltage on the pump, mechanical rotation, and ensure the circuit has pressure and is bled. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Cointra circulator pump 9158441
- Catalogue reference
- 9158441
- Brand
- Cointra
- Type of part
- Pumps
- Units in stock
- 4 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Actual manufacturer
- Grundfos (manufactured for Cointra)
- Printed brand name
- Cointra
- Model (Type)
- UPS15-50 CACAO
- Product code (P/N)
- 59935511
- Production Code (PC)
- 0315
- Voltage
- 230V~
- Frequency
- 50 Hz
- Condenser
- 2 µF
- IP protection rating
- IP 44
- Thermal protection
- TF 95
- Insulation class
- Class H
- Maximum pressure
- 3 bar
- Speed 1 (current/power)
- 0.18 A / 40 W
- Speed 2 (current/power)
- 0.28 A / 60 W
- Speed 3 (current/power)
- 0.38 A / 85 W
- Place of manufacture
- DK (Denmark)
- The part has the Cointra brand printed on the plate, but the Grundfos logo is also present: it is manufactured by Grundfos for Cointra. It is not a Cointra-manufactured part.
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Cointra Edyco ED 21 I Manual (PDF)Document © Cointra, provided as a technical reference.