Grundfos Circulating Pump Beretta Ciao 24 Ref. 59945513
Refurbished Beretta Pumps Grundfos

Grundfos Circulating Pump Beretta Ciao 24 Ref. 59945513

Grundfos UP 15-50 AO B/BC circulator pump, compatible with Beretta Ciao 24 boilers and other models in the Beretta range. It circulates the heating water through the primary circuit. The replacement requires first confirming the fault of the part through technical diagnosis, even when the circulator does not start, makes noise, does not provide pressure, or the boiler loses water circulation. Manufacturer reference P/N 59945513, power supply 230V at 50Hz, maximum pressure 3 bar.

Type of part
Pumps
Catalogue reference
20002906
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Beretta boilers compatible with reference 20002906

Circulating pump with reference 20002906. Two confirmed compatibilities: Ciao 24 CAI and Ciao 24 CSI.

Proven compatibility

Boiler modelFamilyVerification
Beretta Ciao 24 CAICiao 24Contrasted
Beretta Ciao 24 CSICiao 24Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 20002906 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 20002906. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulator pump 20002906

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler ignites, but the radiators are cold or take a long time to heat up.

    Cause: The water is not circulating properly because the pump rotor is not spinning.

    Touch the pump to see if it vibrates or is hot: if you don't notice any movement, try to unlock it with the front screw before replacing it.

  • 02

    The pump makes a buzzing sound but does not start.

    Cause: The rotor is stuck, probably due to limescale or rust accumulated after a period of disuse.

    With the boiler turned off, use a flat screwdriver on the front screw to try to turn the shaft and release it.

  • 03

    There is rattling or vibration in the area of the pump when the heating is turned on.

    Cause: It could be due to air in the circuit or because the rotor is rubbing unevenly.

    Bleed the radiators and the pump bleeder before considering it a spare part issue.

  • 04

    There is moisture or dripping at the base of the pump.

    Cause: The shaft seal is worn out and no longer seals the water properly.

    Dry the area and check in cold if the dripping returns after a while of use, to ensure that it is coming from the shaft and not from a nearby fitting.

Beretta fault codes that require diagnosis

CodeFaultTechnical checks
A02The boiler shuts down due to overheating.If the circulation pump is blocked or not working, the water does not circulate properly and heats up too quickly, activating the safety system. Check that the pump is receiving power and that the shaft rotates freely. If the supply water is much hotter than the return water, it is likely that the pump is not circulating properly.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Beretta circulator pump 20002906

Catalogue reference
20002906
Uniclima internal SKU
BCBCIAO24
Brand
Beretta
Type of part
Pumps
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Grundfos
Model
UP 15-50 AO B/BC
Manufacturer code
P/N 59945513
Nominal voltage
230V~
Frequency
50Hz
Condenser
2.5 µF
Protection rating
IP 44
Insulation class
Class H / TF 95
Maximum pressure
3 bar
Nominal current
0.42 A
Power (P1)
95 W
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the circulator pump 20002906

Is the circulation pump of the Beretta Ciao 24 original Beretta or is it manufactured by another company?
The circulator is manufactured by Grundfos, model UP 15-50 AO B/BC; Beretta installs it in these boilers.
Which models are compatible with the Grundfos Beretta Ciao 24 Ref. 59945513 circulation pump?
It is compatible with the Ciao 24 CAI and Ciao 24 CSI models.
What is the maximum pressure supported by the Grundfos pump of the Beretta Ciao 24?
It supports up to 3 bar, according to the PCB.
When should the circulation pump of the Beretta Ciao 24 be replaced?
The technical diagnosis must confirm that it is necessary to replace it, even when the circulator does not start, makes noise, does not provide pressure, or the boiler loses water circulation.
What fault code is documented for this circulation pump?
The documented fault code is A02.
What is the reference for the circulation pump compatible with the Beretta Ciao 24?
BCBCIAO24 is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.

Spare parts related to Beretta Ciao 24

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Grundfos Circulating Pump Beretta Ciao 24 Ref. 59945513