Grundfos Circulating Pump for Beretta Ciao 24 CSI Ref. R10021792
Refurbished Beretta Pumps Grundfos

Grundfos Circulating Pump for Beretta Ciao 24 CSI Ref. R10021792

Grundfos circulator pump (model Type UPS 15-...130, according to label) installed in Beretta Ciao and Kompakt/Super Kompakt boilers. It moves the water in the heating circuit. The replacement requires first confirming the fault of the part through technical diagnosis, even when it does not start, makes noise, leaks, or does not provide sufficient pressure in the circuit.

Type of part
Pumps
Catalogue reference
R10021792
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Beretta boilers compatible with reference R10021792

Circulating pump with reference R10021792. Five confirmed compatibilities: Ciao 24 CAI and Ciao 24 CSI.

Proven compatibility

Boiler modelFamilyVerification
Beretta Ciao 24 CAIBerettaContrasted
Beretta Ciao 24 CSIBerettaContrasted
Beretta Kompakt 22 CAIBerettaContrasted
Beretta Super Kompakt 24 CAIBerettaContrasted
Beretta Super Kompakt 24 CSIBerettaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part R10021792 is the one for your boiler.

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference R10021792. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulator pump R10021792

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pump does not start or does not rotate when requesting heating.

    Cause: The impeller may be stuck due to limescale, especially if the pump has been inactive for a long time.

    With the boiler cold, try to unlock the shaft by turning it by hand using the front screw before replacing the pump.

  • 02

    There is noise or vibration during operation, louder than usual.

    Cause: Air in the circuit or low water pressure can cause cavitation in the pump, which generates that characteristic noise.

    Bleed the radiators and check the pressure on the manometer before considering that the pump is faulty.

  • 03

    Water is dripping from the body or from the shaft of the pump.

    Cause: The shaft seal is losing tightness due to wear and allows water to escape gradually.

    Dry the area and observe exactly where the water is coming from before replacing the pump, to rule out a nearby gasket.

  • 04

    The heating heats little or unevenly, as if there is a lack of pressure in the circuit.

    Cause: If the pump does not move the adequate flow, the hot water does not circulate with enough force through all the radiators.

    Check the pressure of the system on the manometer and make sure there are no closed radiators before attributing it to the pump.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Beretta R10021792 circulation pump.

Catalogue reference
R10021792
Uniclima internal SKU
BCCBUPS-15/50
Brand
Beretta
Type of part
Pumps
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

manufacturer
Grundfos
Partial model
Type UPS 15-...130
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the circulator pump R10021792

Who actually manufactures the pump for my Beretta Ciao 24 CSI?
Grundfos, according to the readable logo on the part label.
Does this Grundfos pump work for a Beretta Super Kompakt 24 CAI?
Yes, the Super Kompakt 24 CAI is on the list of boilers compatible with this pump.
How do I know if the pump of my Beretta Kompakt 22 CAI is faulty?
If it doesn't start, makes noise, leaks water, or the heating doesn't work well, it is usually this component.
Is this pump also suitable for a Beretta Ciao 24 CAI?
Yes, the Ciao 24 CAI is among the boilers compatible with this pump.

Spare parts related to Beretta Beretta

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Grundfos Circulating Pump for Beretta Ciao 24 CSI Ref. R10021792