Beretta Exclusive MIX 26 Circulating Pump Ref. 596937
Refurbished Beretta Pumps

Beretta Exclusive MIX 26 Circulating Pump Ref. 596937

When you open the tap or turn on the heating, the Beretta Exclusive MIX 26 Circulating Pump is responsible for directing and distributing water between the boiler circuits. If this part fails, you will notice leaks, loss of pressure, or issues with hot water production. It is installed in Beretta boilers from the Ciao, City, Exclusive, and Mynute ranges, among others. A technician must confirm through diagnosis whether it needs to be replaced when you experience the mentioned symptoms to avoid further problems.

Type of part
Pumps
Catalogue reference
596937
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Beretta boilers compatible with reference 596937

Circulating pump with reference 596937. Four verified compatibilities: Ciao and City.

Proven compatibility

Boiler modelFamilyVerification
Beretta CiaoBerettaContrasted
Beretta CityBerettaContrasted
Beretta ExclusiveBerettaContrasted
Beretta MynuteBerettaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference 596937 is the part for your boiler.

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 596937. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulation pump 596937

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The radiators are not heating properly or take a long time to heat up even though the boiler is on.

    Cause: if the impeller of the pump does not rotate properly, the water does not circulate through the heating circuit

    bleed the air from the radiators and check the pressure on the manometer before considering the pump as faulty

  • 02

    A buzzing or strange noise is heard in the pump area when starting the heating.

    Cause: the rotor may be partially stuck due to scale or air trapped inside the pump

    With the boiler turned off, try to manually turn the central screw of the pump's bleed valve, if it is accessible.

  • 03

    A ring of water or droplets appears around the pump.

    Cause: the shaft seal wears out over time, especially if the pump has been idle for a long time

    Dry the area and check in both cold and hot conditions if the leak is continuous or only appears when the water heats up and expands.

  • 04

    The pump does not start after the summer break.

    Cause: the rotor gets stuck due to sediment when it hasn't moved for months

    try to unclog the shaft with a screwdriver on the front screw, if the model allows it, before replacing it

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Technical sheet: Beretta 596937 circulator pump

Catalogue reference
596937
Uniclima internal SKU
HBEMIX26
Brand
Beretta
Type of part
Pumps
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions: 596937 circulator pump

Is this circulation pump suitable for a Beretta Exclusive boiler?
Yes, it is on the list of compatible boilers, along with Beretta Ciao, City, and Mynute.
When should the circulation pump of a Beretta Ciao boiler be replaced?
The technical diagnosis must confirm that it is necessary to replace it, even when it does not start, makes noise, or leaks water.
What is mounted next to this pump in the photos of the Beretta Exclusive?
The condenser cover and the terminal box, photographed from the side.
Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Beretta Exclusive MIX 26 Circulating Pump Ref. 596937