Grundfos Circulating Pump Chaffoteaux MC 2 24 FF P/N 59915402
Grundfos UP 15-50 A0 circulating pump mounted in Chaffoteaux boilers (MC 2 24 FF, Aludra Delta, Balixia, Calydra, Compy MX2, Elexia Comfort, Maya, Mira, MX2, Niagara Delta). It circulates the water in the heating circuit between the boiler and the radiators. It is replaced when it does not start, makes noise, leaks from the shaft, or the boiler does not heat with the burner on.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 61301964
Circulating pump with reference 61301964. Four confirmed compatibilities: MX2 and MX2 24 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux MX2 | MX2 | Contrasted |
| Chaffoteaux MX2 24 FF | MX2 | Contrasted |
| Chaffoteaux Compy MX2 24 FF | MX2 | Contrasted |
| Chaffoteaux B60 30 BFFI | B60 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 61301964 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 61301964. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulation pump 61301964 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler turns on and the burner works, but the radiators do not heat up.
Cause: The pump is not moving the water in the circuit even though the heat exchanger is heating.
Make sure the shaft rotates freely by turning it by hand through the front slot of the motor before replacing it.
- 02
A constant buzzing or vibrating sound is heard in the pump.
Cause: The impeller is spinning with friction, or there is air in the circuit and the motor has to work harder to overcome that resistance.
Bleed the air from the circuit using the nearest bleed valve and check if the noise decreases before replacing it.
- 03
A leak or water ring appears under the body of the pump.
Cause: The mechanical seal of the shaft has lost its tightness and is allowing water to pass through slowly.
Dry the area, turn on the heating, and locate whether the leak comes from the shaft or from a gasket of the casing before purchasing it.
- 04
The pump does not start when the heating is turned on.
Cause: The winding is not receiving current or the rotor is blocked and cannot start.
With the boiler turned off and cold, try turning the shaft by hand through the front slot to rule out that it is stuck.
Fault codes Chaffoteaux that this part resolves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 60-70-80 | Lack of water circulation | The circulating pump (stuck, seized, with air or without power) prevents the primary flow and triggers this code; check 230 V at the pump, bleed the circuit, and release/confirm shaft rotation from the front cap. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Chaffoteaux circulator pump 61301964
- Catalogue reference
- 61301964
- Brand
- Chaffoteaux
- Type of part
- Pumps
- Units in stock
- 5 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- Grundfos
- Model (Type)
- UP 15-50 A0
- Product code (P/N)
- 59915402
- Production Code (PC)
- 0149CY
- Voltage
- 230V~
- Frequency
- 50 Hz
- Condenser
- 2 µF
- Nominal current
- 0.39 A
- Power P1
- 90 W
- IP protection rating
- IP 42
- Thermal protection
- TF 95
- Insulation class
- Class H
- Maximum pressure
- 6 bar
- Serial number
- 1301796