Maya 24 FF Circulating Pump - CMSL15/5-1 - Ref. 1302255
Refurbished Chaffoteaux Pumps Wilo

Maya 24 FF Circulating Pump - CMSL15/5-1 - Ref. 1302255

The Maya 24 FF - CMSL15/5-1 - Ref. 1302255 circulator pump from Wilo is a component responsible for moving water through the heating circuit of your boiler. If it malfunctions, you will notice cold radiators, strange noises, or even overheating due to a lack of water circulation. This model is compatible with boilers such as MX2, MX2 24 FF, and B60 30 BFFI, among others. A technician should confirm through diagnosis whether it needs to be replaced when you start experiencing these symptoms to avoid further damage to the heating system.

Type of part
Pumps
Catalogue reference
61301964
Warranty
1 year
VAT included Stock · 5 units
Compatibility

Chaffoteaux boilers compatible with reference 61301964

Circulating pump with reference 61301964. Four confirmed compatibilities: MX2 and MX2 24 FF.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux MX2MX2Contrasted
Chaffoteaux MX2 24 FFMX2Contrasted
Chaffoteaux Compy MX2 24 FFMX2Contrasted
Chaffoteaux B60 30 BFFIB60Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 61301964 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 61301964. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulator pump 61301964

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is working but the water is not circulating: radiators are cold or the boiler locks out due to overheating.

    Cause: If the impeller is blocked or spins loosely, the water does not move and the boiler may lock out due to excessive internal temperature.

    Check if the shaft rotates freely with the front screw (if it has one) before replacing the entire pump.

  • 02

    A buzzing or vibrating sound is heard in the pump when starting the heating.

    Cause: It could be air in the circuit, low pressure, or scale in the impeller, not necessarily the motor.

    Check the circuit pressure and bleed the system before purchasing the part.

  • 03

    The pump does not start, it remains silent when requesting heating.

    Cause: Burnt motor or seized shaft after a long period of inactivity, typical if the boiler has been unused for months for heating.

    Try to manually release the shaft and check that power is reaching the terminals before discarding it.

  • 04

    Water is dripping from the pump shaft area.

    Cause: The mechanical seal wears out and starts to leak from there.

    Confirm that the dripping originates from the body of the pump and not from a nearby fitting or bleed valve before requesting the spare part.

Chaffoteaux fault codes that require diagnosis

CodeFaultTechnical checks
60-70-80Lack of water circulationThe circulating pump/air separator (stuck, seized, with air or without power) prevents the primary flow and triggers this code; check 230 V at the pump, bleed the circuit, and release/confirm shaft rotation from the front cap.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Chaffoteaux circulator pump 61301964

Catalogue reference
61301964
Uniclima internal SKU
BCCM24FF
Brand
Chaffoteaux
Type of part
Pumps
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

model
CMSL15/5-1
manufacturer reference
1302255
capacitor
2.6 µF - 400V DB
voltage
230V~ 50Hz
protection grade / nominal pressure
IP44 - PN6
thermal class
Class F / TF95
speed
2200 min-1
current
0.38 A
power
86 W
batch code
4513085 (42/04)
Frequently Asked Questions

Frequently asked questions about the circulator pump 61301964

What is the reference for the pump of the Maya 24 FF?
CMSL15/5-1 is the model and 1302255 is the manufacturer's reference, according to the PCB.
Is this pump suitable for my boiler Maya 24 FF?
Yes, Maya 24 FF is on the list of compatible boilers.
What capacitor does the CMSL15/5-1 pump of the Maya 24 FF use?
2.6 µF - 400V DB, according to the PCB.
What is the consumption of the pump of the MX2 24 FF boiler?
86 W, according to the PCB, since the MX2 24 FF uses the same pump CMSL15/5-1 as the Maya 24 FF.
Why does the CMSL15/5-1 pump of the Maya 24 FF need to be replaced?
Because it doesn't start, makes noise, or loses flow.
What is the reference for this circulator pump?
BCCM24FF is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.

Spare parts related to Chaffoteaux MX2

Entrega calculada por destino Delivery time shown at checkout
1-year warranty reviewed and tested
14-day return uninstalled parts
Technical support we verify your model
Maya 24 FF Circulating Pump - CMSL15/5-1 - Ref. 1302255