Grundfos UP 15-50 A0/BC Circulating Pump for Beretta Kompakt 24 CSI - Ref. R10024975
RefurbishedBerettaPumpsGrundfos

Grundfos UP 15-50 A0/BC Circulating Pump for Beretta Kompakt 24 CSI - Ref. R10024975

Stock · 5 units

Grundfos UP 15-50 A0/BC circulator pump (P/N 59945504) for Beretta Kompakt 24 CSI boiler. It circulates water for the heating circuit and domestic hot water. Manufacturer and code identified from the part label. Plate data: 230V~ 50Hz, 0.39A, 90W, capacitor 2µF, IP44, insulation class H, maximum pressure 3 bar, production code PC:0102BC.

VAT included

Compatibility

Beretta boilers compatible with reference R10024975

Circulating pump with reference R10024975. A proven compatibility: Kompakt 24 CSI Grundfos UP 15-50 AO/BC.

Proven compatibility

Boiler modelFamilyVerification
Beretta Kompakt 24 CSI Grundfos UP 15-50 AO/BCBerettaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. R10024975 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference R10024975. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the circulator pump R10024975 resolves.

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The radiators do not heat up even though the boiler is on.

    Cause: If the pump is not working, the hot water does not circulate through the system.

    Check if the pump vibrates or makes noise when calling for heat; if it doesn't move, check the power supply to the connector.

  • 02

    The pump makes noises or feels vibrations when touched.

    Cause: This could be due to air in the rotor or wear of the bearing after prolonged use.

    Bleed the heating circuit first: often, the noise decreases when the air is removed.

  • 03

    There is water accumulated at the base of the pump, near the shaft.

    Cause: The seal that seals the shaft deteriorates over time and can allow water to pass through.

    Dry the area, turn on the heating, and observe if the humidity reappears on the shaft after a while of operation.

  • 04

    The pump does not start after stopping the boiler in summer.

    Cause: The rotor can get stuck if it hasn't been used for a long time, especially if the water is hard.

    Before replacing it, try to manually unlock the shaft with a flat screwdriver on the front screw, as indicated by the manufacturer.

Fault codes for Beretta that this part resolves.

CodeFaultDiagnosis and solution
71PRIMARY SENSOR (T)If the circulating pump is blocked or faulty, there is no flow in the primary; the flow temperature rises quickly, and the boiler detects an overtemperature at the flow sensor (71). Check the power supply to the pump, the start/rotation of the rotor, and ensure there is actual circulation (valves open, no air).

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Beretta R10024975 circulation pump.

Catalogue reference
R10024975
Brand
Beretta
Type of part
Pumps
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
1-2 business days
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Manufacturer
Grundfos
Component code
UP 15-50 A0/BC (P/N 59945504)
Voltage
230V~
Frequency
50Hz
Condenser
2 µF
Degree of protection
IP 44
Insulation class
Class H
Maximum pressure
3 bar
Nominal current
0.39 A
Power
90 W
Production code
PC:0102BC
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the circulator pump R10024975

Is Grundfos the original manufacturer of the pump for the Beretta Kompakt 24 CSI?
Yes, the label identifies the manufacturer as Grundfos, model UP 15-50 A0/BC.
What is the maximum pressure supported by the Grundfos UP 15-50 A0/BC pump of the Kompakt 24 CSI?
3 bar, according to the data plate.
What is the Grundfos product code for the pump of the Beretta Kompakt 24 CSI?
P/N 59945504, production code PC:0102BC.
What is the power consumption of the Beretta Kompakt 24 CSI pump?
90 W, 0.39 A at 230V~ 50Hz, according to the label.
What capacitor does the Grundfos UP 15-50 A0/BC pump use?
2 µF, according to the label.

Spare parts related to Beretta Beretta

Delivery 1–2 daysworking days, mainland Spain
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Grundfos UP 15-50 A0/BC Circulating Pump for Beretta Kompakt 24 CSI - Ref. R10024975