Grundfos UPMO 15-60 Circulating Pump Compatible for Neobits, Novanox, Platinum Max, Vega Plus, and Victoria 24/24F - Ref. BDR7732750
Circulating pump for boiler, manufactured by Grundfos, model UPMO 15-60 Compatta, marketed under the BDR Thermea group brand (internal code BDR7732750). It is used in Neobits, Novanox, Platinum Max, Vega Plus, and Victoria 24/24 and 24/24F boilers. It is responsible for moving the water in the heating circuit; it is replaced when it does not start, makes noise, leaks, or when the boiler loses pressure or circulation.
VAT included
Consult via WhatsAppBaxi boilers compatible with reference 7801354
Circulating pump with reference 7801354. Four confirmed compatibilities: VICTORIA 24/24 and VICTORIA 24/24 F.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi VICTORIA 24/24 | Victoria | Contrasted |
| Baxi VICTORIA 24/24 F | Victoria | Contrasted |
| Baxi NEOBIT S 24/24 | Neobit | Contrasted |
| Baxi NEOBIT S 24/24 F | Neobit | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 7801354 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 7801354. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the circulation pump 7801354 resolves.
The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pump does not start or does not rotate when requesting heating.
Cause: If the motor does not respond, the water does not circulate even though the boiler is on.
Make sure the shaft rotates freely by manually unlocking it before replacing the pump.
- 02
There is noticeable noise or strong vibration in the pump during operation.
Cause: A worn bearing or trapped air in the pump body causes noise even though it continues to move water.
Bleed the air from the heating circuit before declaring the pump faulty.
- 03
There is a water leak around the body of the pump.
Cause: The internal mechanical seal wears out over time and allows water to pass through the shaft.
Locate whether the leak is coming directly from the pump body and not from a nearby connection or joint before replacing it.
- 04
The radiators are not heating properly even though the boiler is working.
Cause: If the pump does not move enough water, the heat generated does not get distributed throughout the system.
Check that the pump is not set to a speed that is too low or is completely stopped before replacing it.
- 05
The boiler shows a low pressure fault or lack of circulation.
Cause: The control board interprets the lack of water movement as a circulation fault and locks the boiler.
Check the circuit pressure and that the pump is running before attributing the fault to the pump itself.
Fault codes Baxi that this part resolves
| Code | Fault | Diagnosis and solution |
|---|---|---|
| E25 | Activation of the safety device due to probable pump blockage. | The seizing or failure of the pump prevents circulation and the primary circuit overheats quickly; check the 230 V supply to the pump and unblock/inspect the shaft from the front cap and the filter/return. |
| E26 | Activation of the safety device due to probable pump blockage. | With the pump blocked, the flow exceeds the setpoint due to lack of flow (overtemperature); check that the pump rotates freely and receives voltage, bleed air, and inspect for obstructions in the circuit/filter. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Baxi 7801354 circulation pump.
- Catalogue reference
- 7801354
- Brand
- Baxi
- Type of part
- Pumps
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Manufacturer
- Grundfos
- Model
- UPMO 15-60 Compatta
- Internal code (label)
- BDR7732750
- Batch/serial number (possible)
- 09010 / 2234017744