Wilo circulator pump model ZRS15/4-1 Ku, identified by its own label. It moves the water in the circuit of Saunier Duval boilers from the Isomax and Isotwin ranges. The replacement requires first confirming the fault of the part through technical diagnosis, even when the boiler is not heating properly, the pump is making noise or vibrating, it does not start, or it is leaking water from the shaft seal. Wilo article code: 4518125.

Type of part
Pumps
Catalogue reference
05738300
Warranty
1 year
VAT includedStock · 2 units
Compatibility

Saunier Duval boilers compatible with reference 05738300

Circulating pump with reference 05738300. Six confirmed compatibilities: Isomax C 28 E and Isomax F 28 E.

Proven compatibility

Boiler modelFamilyVerification
Saunier Duval Isomax C 28 EIsomaxContrasted
Saunier Duval Isomax F 28 EIsomaxContrasted
Saunier Duval Isomax C 28 E2IsomaxContrasted
Saunier Duval Isotwin C 24 EIsotwinContrasted
Saunier Duval Isotwin F 24 EIsotwinContrasted
Saunier Duval Isotwin F 28 E2IsotwinContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 05738300 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 05738300. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the circulator pump 05738300

The circulation pump circulates the water in the heating circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler takes a long time to provide hot water or does not heat the radiators properly.

    Cause: If the pump does not move the necessary flow, the heat generated is not distributed as quickly as it should be through the circuit.

    Bleed the highest radiator in the system before considering replacing the pump.

  • 02

    There is noticeable noise, buzzing, or vibration in the area of the pump when the boiler is operating.

    Cause: A worn bearing or trapped air causes the rotor to not spin smoothly and transmits that noise to the casing.

    Check the circuit pressure on the manometer; low pressure promotes air in the pump and can be mistaken for a fault in the rotor.

  • 03

    The pump does not start even though the boiler is requesting heat and the rest ignites normally.

    Cause: The shaft may be seized due to scale or the motor winding may have failed, so it does not rotate despite receiving a start command.

    With the boiler turned off and unplugged, try to turn the shaft by hand through the front slot of the motor; if it doesn't budge, confirm the blockage before replacing it.

  • 04

    There is a drip or water leak right below the pump, at the joint with the body.

    Cause: The mechanical seal of the shaft loses tightness due to wear and allows a slow and constant leak.

    Dry the area and check after a few hours of operation if the dripping reappears right there and not from a nearby fitting or bleed valve.

Fault codes Saunier Duval that require diagnosis

CodeFaultTechnical checks
11Pump blocked.If the sanitary pump 05738300 seizes or fails electrically during the DHW recharge, the electronics detect circulator blockage and trigger "11". Verification: force DHW demand, check 230 V and current in the pump, and release/inspect the shaft from the front cap.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Saunier Duval 05738300 circulation pump.

Catalogue reference
05738300
Uniclima internal SKU
BCIF24E
Brand
Saunier Duval
Type of part
Pumps
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Manufacturer
Wilo
Model
ZRS15/4-1 Ku
Item code
4518125
Voltage
~230V 50Hz
Condenser
2 µF - 400VDB
Current
0.31 A
Absorbed power
71 W
Speed
2100 min-1
Degree of protection
IP44
Thermal class
Class F - TF85
Frequently Asked Questions

Frequently asked questions about the circulator pump 05738300

Is this Wilo ZRS15/4-1 Ku pump compatible with the Saunier Duval Isotwin F24E?
Yes, it is on the list of compatible boilers along with Isomax C28E, Isomax F28E, Isomax F28E2, Isotwin C24E, Isotwin COND F30E, and Isotwin F28E2, among others.
What manufacturer is the pump of the Isotwin F24E?
Wilo, indicated on the part's own label.
What is the article code for this Wilo pump for the Isomax C28E?
Model Wilo ZRS15/4-1 Ku, article code 4518125.
Why is the pump of the Isotwin/Isomax replaced?
It should be checked when the boiler is not heating properly, the pump makes noise or vibrates, it does not start, or it leaks water from the shaft seal. Replacement requires a technical diagnosis.

Spare parts related to Saunier Duval Isomax

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Saunier Duval Isotwin F24E Circulating Pump Wilo Ref. 05738300