Vaillant Safety Valve Ref. 190717
Safety valve set to 3 bar, with a 1/2 inch connection and TÜV certification SV·18-1089·H·50 marked on the body. In compatible Vaillant boilers, it limits the water circuit pressure and discharges if the set pressure is exceeded. It is replaced when it continuously drips, does not close after bleeding, or does not activate at 3 bar.
VAT included
Consult via WhatsAppVaillant boilers compatible with reference 190717
Safety valve with reference 190717. 21 verified compatibilities: VC 240 and VC 240/1.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Vaillant VC 240 | VC / Thermocompact | Contrasted |
| Vaillant VC 240/1 | VC / Thermocompact | Contrasted |
| Vaillant VC 242 E | VC / Thermocompact | Contrasted |
| Vaillant VC 242/1 E | VC / Thermocompact | Contrasted |
| Vaillant VCW (series) | VCW / Thermocompact | Contrasted |
| Vaillant VCM 180 | VCM / Turboblock | Contrasted |
| Vaillant VCM 180/1 | VCM / Turboblock | Contrasted |
| Vaillant VCM 182 E | VCM / Turboblock | Contrasted |
| Vaillant VCM 182/1 E | VCM / Turboblock | Contrasted |
| Vaillant VCM 240 | VCM / Turboblock | Contrasted |
| Vaillant VCM 240/1 | VCM / Turboblock | Contrasted |
| Vaillant VCM 242 E | VCM / Turboblock | Contrasted |
| Vaillant VCM 242/1 E | VCM / Turboblock | Contrasted |
| Vaillant VCM 255/2 E | VCM / Turboblock | Contrasted |
| Vaillant VCM 260 | VCM / Turboblock | Contrasted |
| Vaillant VCM 260/1 | VCM / Turboblock | Contrasted |
| Vaillant VCM 282 E | VCM / Turboblock | Contrasted |
| Vaillant VCM 282/1 E | VCM / Turboblock | Contrasted |
| Vaillant VM (series) | VM / VMW | Contrasted |
| Vaillant VMW (series) | VM / VMW | Contrasted |
| Vaillant T3 (series) | T3 | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 190717 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 190717. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the safety valve 190717 resolves
The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
It is leaking or continuously bleeding water without the boiler exerting pressure.
Cause: The seat does not seal and allows water to escape even with the circuit below the 3 bar setting.
Check the pre-charge pressure of the expansion vessel when cold before replacing the gas valve: a vessel without air causes the circuit to easily increase in pressure.
- 02
Water drains every time the boiler heats up, just when it reaches 3 bar.
Cause: It is its safety function, but if it trips frequently, it indicates that the circuit is operating very close to the set limit.
Measure the pressure when cold and hot with the boiler's manometer; if it rises from 1 to more than 3 bar when heating, check the expansion vessel before replacing the gas valve.
- 03
After firing, it does not seal again and continues to leak water.
Cause: The seat remains with a particle trapped after the discharge and the closure is not airtight.
Pull the bleed lever a couple more times to try to remove the dirt from the seat before declaring it faulty.
- 04
The circuit gradually loses pressure and needs to be topped up every few days.
Cause: An internal leak in the valve allows water to escape without any visible dripping.
Check for recent moisture in the discharge pipe or on the floor under the boiler before concluding that it is the gas valve.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the safety valve Vaillant 190717
- Catalogue reference
- 190717
- Brand
- Vaillant
- Type of part
- Safety Valves
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- 1-2 business days
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Setpoint
- 3 bar
- Connection
- 1/2"
- Certification code
- TÜV·SV·18-1089·H·50
- Reference
- 190717
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Vaillant VCM 182/1 E Manual (PDF)Document © Vaillant, provided as a technical reference.